Search results for "Molar"
showing 10 items of 1069 documents
<i>In vitro</i> evaluation of microleakage in Class II composite restorations: High-viscosity bulk-fill <i>vs</i> conventiona…
2019
This study compared marginal microleakage of Class II cavities restored with bulk-fill resin (Filtek™ Bulk Fill) and conventional composite resin (Filtek™ Supreme XTE). Two standardized Class II cavities were prepared in forty extracted human molars. The gingival margin was located above the cemento-enamel junction for twenty molars (groups 1 and 2) and apically for the other twenty (groups 3 and 4) (n=20). The occlusomesial cavity was filled with bulk-fill resin by insertion in bulk (groups 1 and 3) and the occlusodistal cavity was restored with conventional composite using incremental technique (groups 2 and 4). The teeth were thermocycled (500 cycles 5-55°C), stained and observed under l…
Evaluation of the enamel etching pattern of self-etching adhesives
2010
Objectives: To evaluate the capacity of seven self-etching adhesives (SEAs) to demineralize ground enamel in comparison with traditional phosphoric acid etchant (PAE) using SEM and statistical analysis. Materials and methods: 80 caries-free extracted human third molars were divided into 8 groups ( n = 10). Enamel bur-cut surfaces were prepared and, strictly following the manufacturers’ instructions, treated with three priming agents of two-step self-etching adhesives: Aqua Resulcin Prime (Group 1); Peak™ (Group 2); Clearfil Protect Bond (Group 3); four one-step self-etch (all-in-one) adhesives, G-Bond (Group 4); Artegral One (Group 5); Clearfil S3 Bond (Group 6); Adper Easy Bond (Group 7); …
Marginal quality of a full-body bulk-fill composite placed with an universal adhesive system in etch-and-rinse and self-etch mode: An
2020
Background Marginal seal of a nanohybrid bulk-fill composite compared to a nanohybrid conventional composite, using a universal adhesive (UA) applied in etch-and-rinse (ER) and self-etch (SE) mode was investigated. Material and Methods Thirty-six intact molars were selected and two standardized cavities in each tooth were prepared and allocated into four groups according to restorative material and etching strategy. All samples were placed in a 1% methylene blue solution for 24 h, then cut in the middle of the restorations obtaining two parts (n=144) and used for microscopic evaluation (50x) for dye penetration measurements. Results The data were analysed by ANOVA and Tukey post-hoc test (p…
Dentin bond strength and degree of conversion evaluation of experimental self-etch adhesive systems
2014
Background: The aim of this study was to investigate the effect of different concentrations of 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) monomer in one-step self-etch experimental adhesives on dentinal microshear bond strength (μSBS), their degree of conversion and bonded micro structure. Material and Methods: Composite resin cylinders (Clearfil AP-X) were bonded on human sound molar dentinal surfaces by using five experimental one-step self-etching adhesives (1-SEAs) containing 0% (E0), 5% (E5), 10% (E10), 15% (E15), 20% (E20) (by weight) 10-MDP monomer and Clearfil S3 Bond (CS3) as a control. After 24 hours, microshear bond strength was tested. The degree of conversion was als…
Evaluation of marginal sealing quality of restorations with low shrinkage composite resins
2020
Background This study compared the quality of marginal sealing in the gingival wall of class II preparations of two low-shirinkage resins of the bulk fill type with a conventional resin isolated or associated with a glass ionomer cement (GIC). Material and methods 40 human molars were divided into 4 groups and 80 occlusal-mesial and occlusal-distal restorations were performed with the following materials: SureFil SDR flow, Filtek Bulk Fill Posterior, Z250 resins and Riva Light Cure GIC. 40 restorations were evaluated in Scanning Electron Microscopy (SEM) with Elemental Microanalysis Spectrometry (EDS) initially and the remainder after a period of 6 months of aging in a 37 ± 5°C oven. An ave…
Effect of rotary cutting instruments on the resin-tooth interfacial ultra structure: An in vivo study
2013
Objectives: To evaluate the effect of cutting teeth with different types of burs at various speeds on surface topogra - phy of tooth surface and interfacial gap formation at resin-tooth interface. Material and Methods: The human molars were divided into seven groups: Diamond bur in airrotor (DA) & mi - cromotor (DM), crosscut carbide bur in airrotor (CCA) & micromotor (CCM), plain carbide bur in airrotor (CA) & micromotor (CM) and #600-grit silicon carbide paper (SiC). In five samples from each group Class II box-only cavities were restored. The occlusal surface of four teeth per group was flattened. Two out of four teeth were acid etched. Teeth were subjected for scanning electron microsco…
Does the heat generated by fluorescence-aided caries excavation system effect the pulp temperature of primary teeth irreversibly? An in-vitro evaluat…
2021
Background This study aimed to analyze the effect of the Fluorescence Aided Caries Excavation (FACE) and the remaining dentin thickness on the temperature changes of the pulp chamber. Material and Methods Freshly extracted deciduous molars and a pulpal microcirculation model were used in the study. The sample size was calculated according to power analyses (power at 90%) based on previous studies. Thus, 40 samples were needed. Standard cavities (3x3 mm) were designed to obtain a 2 mm distance through to the pulp chamber, and in each tooth (n=10), these cavities were modified to obtain 1.5 mm, 1mm, and 0.5 mm final distance through to the pulp. Coronal parts of the teeth were placed on an ac…
Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.
2012
Objetives: The aim of this study was to determine which of three methods for measuring BIC (bone-to-implant contact), using vestibular and lingual scanning electron microscopy (SEM) for different implant systems at 15, 30 and 90 days post-surgery was the most precise. An elemental analysis with SEM was used to evaluate neoformed bone composition for three implant systems at the same study times. Material and Methods: 36 implants were placed in eighteen Beagle dogs mandible about one year old and weighing approximately 12-13 kg in order to evaluate bone apposition to three different implant surfaces. It was used the third and fourth premolar and first molar distal sockets in both quadrants o…
In-vitro-Studie der Interferenz von kieferorthopädischer Bebänderung und Füllungswerkstoffen
1992
Discoloring and layers on bands and restorations during fixed orthodontic therapy are well known clinical phenomenon. Because of the complexity of etiological factors an in-vitro model was used in this study. Aim of the study was to examine the amounts and sort of metals which are dissolved. Therefore, respectively 25 normed MOD-cavities in Frasaco-teeth were filled with a non-gamma-2-amalgam (Amalcap plus, Vivadent) and condensed manually or mechanically. In addition, ten crowns of a high golden (Maingold SG, Heraeus) as well as a palladium basis alloy (Albabond A, Heraeus) were casted. Then they were banded with stainless steel bands (Dentaurum) and cemented with a glass ionomer cement (K…
Effects of maxillary protraction determined by laser metrology
1990
In this work we studied some of the main effects of the maxillary protraction orthopedic device. The initial dento-craniofacial reactions induced by maxillary protraction similar to that commonly employed in clinical practice are reported. The fringe counting holographic interferometry technique is used to measure displacements. The experiments were performed on a dried human skull; traction application points were situated over the permanent lateral incisors or over the first permanent molars. The results fundamentally reveal an anterior rotation of the dentomaxillary complex, more intense when traction is applied to the lateral incisors, as shown by a more marked extrusion of the molars i…