Search results for "Monolith"
showing 10 items of 90 documents
Methacrylate ester-based monolithic columns for nano-LC separation of tocopherols in vegetable oils
2010
The separation and determination of tocopherols (Ts) in vegetable oils by nano-LC chromatography with UV-vis detection using lauryl methacrylate ester-based monolithic columns has been developed. The separation of Ts was optimized in terms of mobile phase composition on the basis of the best compromise among efficiency, resolution and analysis time. Using a mobile phase composed of ACN/methanol/water, an excellent resolution between Ts was achieved within 18 min. The LODs were lower than 0.26 μg/mL, being repeatability values of retention time and peak area below 0.15 and 3.1%, respectively. The method was applied to the quantification of Ts and tocotrienols present in several vegetable oil…
Incorporation of zeolitic imidazolate framework (ZIF-8)-derived nanoporous carbons in methacrylate polymeric monoliths for capillary electrochromatog…
2017
A series of metal organic frameworks-derived nanoporous carbons originating from zeolitic imidazolate framework-8 (ZIF-8) crystals as precursors have been prepared via varying the preparation conditions. The ZIF-8-derived carbons were subsequently admixed in the methacrylate monomers containing polymerization mixtures and polymerized to obtain monolithic columns for capillary electrochromatography (CEC). The effect of particle size and content of the ZIF-8-derived carbon materials in the polymerization mixture on the performance of the hybrid monolithic columns was investigated in detail. The resulting composites were characterized using scanning electron microscopy. Using short time UV-ini…
Boronate affinity sorbents based on thiol-functionalized polysiloxane-polymethacrylate composite materials in syringe format for selective extraction…
2021
Abstract In this work, two novel boronate affinity monolithic materials able to extract glycopeptides within a polypropylene syringe are described and compared. The first material was synthesized from glycidyl methacrylate (GMA)-based monoliths modified with poly-3-mercaptopropyl-methylsiloxane (PMPMS) followed by attachment of 4-vinylphenylboronic acid (VPBA) via thiol-ene click reaction. The second material was prepared by using gold nanoparticle (AuNP)-modified monoliths as substrate followed by subsequent attachment of PMPMS and VPBA. The resulting materials were used as sorbents for solid-phase extraction (SPE) to selectively preconcentrate glycopeptides from horseradish peroxidase (HR…
Characterization of microscopic disorder in reconstructed porous materials and assessment of mass transport-relevant structural descriptors
2016
The targeted optimization of the functional properties of porous materials includes the understanding of their transport properties and thus requires knowledge about the relationship between material synthesis, resulting in three-dimensional material morphology, and relevant transport properties. In this Perspective, we present our views and results on the characterization of microscopic disorder in functional porous materials, which are widely used today as fixed beds in adsorption, separation, and catalysis. This allows us to identify structural parameters that impact their mass transport properties and eventually their overall performance in technological operations. We address this comp…
Nanoparticle-Directed Metal–Organic Framework/Porous Organic Polymer Monolithic Supports for Flow-Based Applications
2017
A two-step nanoparticle-directed route for the preparation of macroporous polymer monoliths for which the pore surface is covered with a metal–organic framework (MOF) coating has been developed to facilitate the use of MOFs in flow-based applications. The flow-through monolithic matrix was prepared in a column format from a polymerization mixture containing ZnO-nanoparticles. These nanoparticles embedded in the precursor monolith were converted to MOF coatings via the dissolution–precipitation equilibrium after filling the pores of the monolith with a solution of the organic linker. Pore surface coverage with the microporous zeolitic imidazolate framework ZIF-8 resulted in an increase in su…
“Supported Co3O4-CeO2 monoliths: effect of preparation method and Pd-Pt promotion on the CO/CH4 oxidation activity”
2006
Abstract Two structured composite oxides, Co3O4(30wt%)-CeO2(70wt%), have been prepared by washcoating commercial cordierite monoliths with a CeO2-γAl2O3 layer, on which the active phase Co3O4-CeO2 was added through two different methods: dip-coating from a suspension containing the preformed active oxide or impregnation with a solution of the cobalt and cerium precursors. Morphological characterizations of the monoliths have been performed by BET, and SEM-EDAX analyses. Electronic and reduction properties have been evaluated by XPS and H2-TPR, respectively. The effect of the preparation method has been investigated in the catalytic oxidation of CO, whereas the promotion by a low content of …
The effect of the pore structure and zeta potential of porous polymer monoliths on separation performance in ion-exchange mode.
2007
Most often, in bioseparations involving charged macromolecules, the chromatographic systems have low Reynolds and high Peclet numbers. For such systems, an expression is developed and presented in this work for evaluating the throughput in polymeric monoliths where ion-exchange adsorption occurs, as a function of (i) the pressure drop along the length of the monolith, (ii) the functional form and width of the throughpore-size distribution of the monolith, and (iii) the magnitude of the zeta potential on the surface of the throughpores of the monolith. Gaussian and log-normal throughpore-size distributions whose mean throughpore-size and standard deviation values are based on experimentally …
Photografted methacrylate-based monolithic columns coated with cellulose tris(3,5-dimethylphenylcarbamate) for chiral separation in CEC
2018
A chiral capillary monolithic column for enantiomer separation in capillary electrochromatography was prepared by coating cellulose tris(3,5-dimethylphenylcarbamate) on porous glycidyl methacrylate-co-ethylene dimethacrylate monolith in capillary format grafted with chains of [2(methacryloyloxy)ethyl] trimethylammonium chloride. The surface modification of the monolith by the photografting of [2(methacryloyloxy)ethyl] trimethylammonium chloride monomer as well as the coating conditions of cellulose tris(3,5-dimethylphenylcarbamate) onto the grafted monolithic scaffold were optimized to obtain a stable and reproducible chiral stationary phase for capillary electrochromatography. The effect o…
Performance Enhancement of a Small Animal Positron Emission Tomograph based on Continuous Crystals and Silicon Photomultipliers
2017
La tomografía por emisión de positrones (PET, por sus siglas en inglés) es una técnica de Medicina Nuclear que permite obtener de manera no invasiva imágenes funcionales “in vivo” marcando un compuesto orgánico con un emisor de positrones. Los tomógrafos PET requieren un alta resolución espacial y sensibilidad para estimar con precisión la distribución del radiotrazador en el animal. Frente a los bloques pixelados comúnmente utilizados en PET, los detectores que consisten en la combinación de cristales continuos acoplados a fotodetectores segmentados pueden ofrecer una mayor eficiencia y una alta resolución espacial. Esta última depende de la precisión de los algoritmos de determinación de …
Latest Developments and Results of Radiation Tolerance CMOS Sensors with Small Collection Electrodes
2020
The development of radiation hard Depleted Monolithic Active Pixel Sensors (DMAPS) targets the replacement of hybrid pixel detectors to meet radiation hardness requirements of at least 1.5e16 1 MeV neq/cm2 for the HL-LHC and beyond. DMAPS were designed and tested in the TJ180 nm TowerJazz CMOS imaging technology with small electrodes pixel designs. This technology reduces costs and provides granularity of 36.4x36.4 um2 with low power operation (1 uW/pixel), low noise of ENC < 20 e-, a small collection electrode (3 um) and fast signal response within 25 ns bunch crossing. This contribution will present the latest developments after the MALTA and Mini-MALTA sensors. It will illustrate the imp…