Search results for "Muons."
showing 10 items of 46 documents
"Table 17" of "Elliptic flow of muons from heavy-flavour hadron decays at forward rapidity in Pb-Pb collisions at $\sqrt{s_{\rm NN}}=2.76$ TeV"
2015
pT-differential $v_{2}$ of muons from heavy-flavour decays extracted with Lee-Yang zeros (Sum) method.
Measurement of the atmospheric muon flux with a 4 GeV threshold in the ANTARES neutrino telescope
2010
A new method for the measurement of the muon flux in the deep-sea ANTARES neutrino telescope and its dependence on the depth is presented. The method is based on the observation of coincidence signals in adjacent storeys of the detector. This yields an energy threshold of about 4 GeV. The main sources of optical background are the decay of 40K and the bioluminescence in the sea water. The 40K background is used to calibrate the efficiency of the photo-multiplier tubes.
Cosmic-ray muon flux at Canfranc Underground Laboratory
2019
Residual flux and angular distribution of high-energy cosmic muons have been measured in two underground locations at the Canfranc Underground Laboratory (LSC) using a dedicated Muon Monitor. The instrument consists of three layers of fast scintillation detector modules operating as 352 independent pixels. The monitor has flux-defining area of 1 m${}^{2}$, covers all azimuth angles, and zenith angles up to $80^\circ$. The measured integrated muon flux is $(5.26 \pm 0.21) \times 10^{-3}$ m${}^{-2}$s${}^{-1}$ in the Hall A of the LAB2400 and $(4.29 \pm 0.17) \times 10^{-3}$ m${}^{-2}$s${}^{-1}$ in LAB2500. The angular dependence is consistent with the known profile and rock density of the sur…
Search for anomalous production of prompt like-sign muon pairs and constraints on physics beyond the Standard Model with the ATLAS detector
2012
An inclusive search for anomalous production of two prompt, isolated muons with the same electric charge is presented. The search is performed in a data sample corresponding to 1.6 fb−1 of integrated luminosity collected in 2011 at √s=7 TeV with the ATLAS detector at the LHC. Muon pairs are selected by requiring two isolated muons of the same electric charge with pT>20 GeV and |η|<2.5. Minimal requirements are placed on the rest of the event activity. The distribution of the invariant mass of the muon pair m(μμ) is found to agree well with the background expectation. Upper limits on the cross section for anomalous production of two muons with the same electric charge are placed as a func…
Performance of tracking stations of the underground cosmic-ray detector array EMMA
2018
Abstract The new cosmic-ray experiment EMMA operates at the depth of 75 m (50 GeV cutoff energy for vertical muons; 210 m.w.e.) in the Pyhasalmi mine, Finland. The underground infrastructure consists of a network of eleven stations equipped with multi-layer, position-sensitive detectors. EMMA is designed for cosmic-ray composition studies around the energy range of the knee, i.e., for primary particles with energies between 1 and 10 PeV. In order to yield significant new results EMMA must be able to record data in the full configuration for about three years. The key to the success of the experiment is the performance of its tracking stations. In this paper we describe the layout of EMMA an…
A method for detection of muon induced electromagnetic showers with the ANTARES detector
2012
The primary aim of ANTARES is neutrino astronomy with upward going muons created in charged current muon neutrino interactions in the detector and its surroundings. Downward going muons are background for neutrino searches. These muons are the decay products of cosmic-ray collisions in the Earths atmosphere far above the detector. This paper presents a method to identify and count electromagnetic showers induced along atmospheric muon tracks with the ANTARES detector. The method is applied to both cosmic muon data and simulations and its applicability to the reconstruction of muon event energies is demonstrated. © 2012 Elsevier B.V. All rights reserved.
Characterization of the atmospheric muon flux in IceCube
2015
Muons produced in atmospheric cosmic ray showers account for the by far dominant part of the event yield in large-volume underground particle detectors. The IceCube detector, with an instrumented volume of about a cubic kilometer, has the potential to conduct unique investigations on atmospheric muons by exploiting the large collection area and the possibility to track particles over a long distance. Through detailed reconstruction of energy deposition along the tracks, the characteristics of muon bundles can be quantified, and individual particles of exceptionally high energy identified. The data can then be used to constrain the cosmic ray primary flux and the contribution to atmospheric …
Model discriminating power ofμ→econversion in nuclei
2009
13 pages, 12 figures, 1 table.-- PACS nrs.: 13.35.Bv; 11.30.Hv.-- ArXiv pre-print available at: http://arxiv.org/abs/0904.0957
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
2019
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…
Zenith distribution and flux of atmospheric muons measured with the 5-line ANTARES detector
2010
The ANTARES high energy neutrino telescope is a three-dimensional array of about 900 photomultipliers distributed over 12 mooring lines installed in the Mediterranean Sea. Between February and November 2007 it acquired data in a 5-line configuration. The zenith angular distribution of the atmospheric muon flux and the associated depth-intensity relation are measured and compared with previous measurements and Monte Carlo expectations. An evaluation of the systematic effects due to uncertainties on environmental and detector parameters is presented.