Search results for "Muscle Contraction"

showing 10 items of 569 documents

Mechanical and electrophysiological effects of cromakalim on the human urinary bladder.

1994

The effects of cromakalim on spontaneous and induced mechanical activity of human detrusor muscle were investigated in vitro. Cromakalim produces a concentration-related decrease of spontaneous as well as carbachol- and K(+)-evoked contractions. This is the first study to utilize the patch clamp technique to elucidate the mechanism of action of cromakalim on human detrusor cells. Cromakalim hyperpolarizes the detrusor cells by increasing the net outward current which is most likely carried by potassium ions. In the human urinary bladder, this effect is mediated by a glibenclamide-sensitive potassium channel, as glibenclamide is able to diminish the relaxant effect of cromakalim and to preve…

Detrusor muscleAdultMalemedicine.medical_specialtyCromakalimCarbacholPatch-Clamp TechniquesPotassium Channelsmedicine.drug_classUrologyGuinea PigsUrinary BladderIn Vitro Techniquesurologic and male genital diseasesMembrane Potentialschemistry.chemical_compoundInternal medicineMedicineAnimalsHumansBenzopyransPyrrolesPatch clampUrinary bladderbusiness.industryParasympatholyticsMuscle relaxantMuscle SmoothHyperpolarization (biology)Middle Agedmusculoskeletal systemfemale genital diseases and pregnancy complicationsPotassium channelRatsElectrophysiologyEndocrinologymedicine.anatomical_structurechemistrycardiovascular systemFemaleStress MechanicalbusinessCromakalimmedicine.drugMuscle ContractionInvestigative urology (Berlin, Germany)
researchProduct

Objective, Noninvasive Evaluation of Velopharyngeal Function in Cleft and Noncleft Patients

1998

Objective The purpose of this study was to investigate a new diagnostic method that provides an approach to noninvasive, objective measurement of velopharyngeal movement by acoustic determination of epipharyngeal volume changes with velopharyngeal muscle function. Design This was a case control study, using consecutive samples. Setting This study took place at the Cleft Palate Rehabilitation Center of the University of Mainz, Germany. Patients Subjects were 29 consecutive cleft lip and palate (CLP) patients and 31 controls (21 patients with dysgnathia and 10 healthy volunteers). Intervention A series of transnasal acoustic measurements (pressure wave: 55 dB for 2 milliseconds) of epipharyng…

Diagnostic methodsPharyngeal flap surgeryCleft LipMovementMuscle Relaxationmedicine.medical_treatmentDentistrySpeech TherapySurgical FlapsPharyngeal muscles03 medical and health sciences0302 clinical medicineVelopharyngeal insufficiencyPressureHumansMedicine030223 otorhinolaryngologyRehabilitationbiologybusiness.industryRespirationVelopharyngeal MusclePharynxAcoustics030206 dentistryDysgnathiabiology.organism_classificationCleft PalateSoundmedicine.anatomical_structureOtorhinolaryngologyEvaluation Studies as TopicCase-Control StudiesPharyngeal MusclesPharynxPalate SoftOral SurgerybusinessMuscle ContractionThe Cleft Palate-Craniofacial Journal
researchProduct

Trainierte Skelettmuskulatur als Herzmuskelersatz: Ein neues Therapiekonzept

2008

Electrophysiologybusiness.industrySkeletal musculaturemedicineGeneral MedicineAnatomymedicine.symptombusinessMuscle contractionDMW - Deutsche Medizinische Wochenschrift
researchProduct

Neuromuscular junction disassembly and muscle fatigue in mice lacking neurotrophin-4

2001

Neurotrophin-4 (NT-4) is produced by slow muscle fibers in an activity-dependent manner and promotes growth and remodeling of adult motorneuron innervation. However, both muscle fibers and motor neurons express NT-4 receptors, suggesting bidirectional NT-4 signaling at the neuromuscular junction. Mice lacking NT-4 displayed enlarged and fragmented neuromuscular junctions with disassembled postsynaptic acetylcholine receptor (AChR) clusters, reduced AChR binding, and acetylcholinesterase activity. Electromyographic responses, posttetanic potentiation, and action potential amplitude were also significantly reduced in muscle fibers from NT-4 knock-out mice. Slow-twitch soleus muscles from thes…

End-plate potentialNeuromuscular JunctionElectromyographyBiologyNeuromuscular junctionCellular and Molecular NeuroscienceMicePostsynaptic potentialmedicineAnimalsReceptors CholinergicNerve Growth FactorsMuscle SkeletalMolecular BiologyAcetylcholine receptorMice KnockoutMotor Neuronsmedicine.diagnostic_testMuscle fatigueElectromyographyAge FactorsLong-term potentiationneuromuscular junction; neurotrophin-4; synaptic transmissionCell Biologymedicine.anatomical_structureMuscle Fibers Slow-TwitchMuscle FatigueAcetylcholinesteraseTetanic stimulationNeuroscienceMuscle Contraction
researchProduct

A mixed FES/EMG system for real time analysis of muscular fatigue

2010

International audience; In this article, we present a functional electrical stimulator allowing the extraction in real time of M-wave characteristics from resulting EMG recodings in order to quantify muscle fatigue. This system is composed of three parts. A Labview software managing the stimulation output and electromyogram (EMG) input signal, a hardware part amplifying the output and input signal and a link between the two previous parts which is made up from input/output module (NIdaq USB 6251). In order to characterize the fatigue level, the Continuous Wavelet Transform is applied yielding a local maxima detection. The fatigue is represented on a scale from 0 for a fine shaped muscle to …

Engineering0206 medical engineering02 engineering and technologyElectromyographyUSBSensitivity and SpecificitySignallaw.invention03 medical and health sciences0302 clinical medicinelawElectronic engineeringmedicineHumansMuscle SkeletalSimulationContinuous wavelet transformMuscle fatiguemedicine.diagnostic_testElectromyographybusiness.industryReproducibility of ResultsWavelet transformEquipment Design020601 biomedical engineeringElectric Stimulation[SPI.TRON] Engineering Sciences [physics]/Electronics[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsEquipment Failure AnalysisMaxima and minimaMuscle Fatiguemedicine.symptombusinessAlgorithmsSoftware030217 neurology & neurosurgeryMuscle ContractionMuscle contraction2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
researchProduct

A full body musculoskeletal model based on flexible multibody simulation approach utilised in bone strain analysis during human locomotion

2011

Load-induced strains applied to bone can stimulate its development and adaptation. In order to quantify the incident strains within the skeleton, in vivo implementation of strain gauges on the surfaces of bone is typically used. However, in vivo strain measurements require invasive methodology that is challenging and limited to certain regions of superficial bones only such as the anterior surface of the tibia. Based on our previous study [Al Nazer et al. (2008) J Biomech. 41:1036-1043], an alternative numerical approach to analyse in vivo strains based on the flexible multibody simulation approach was proposed. The purpose of this study was to extend the idea of using the flexible multibod…

EngineeringBiomedical EngineeringBioengineeringBone healingModels BiologicalMotion captureInverse dynamicsElastic ModulusTensile StrengthHumansComputer SimulationTibiaMuscle SkeletalStrain gaugeSimulationTibiabusiness.industryDynamics (mechanics)Multibody simulationGeneral MedicineStructural engineeringComputer Science ApplicationsHuman-Computer InteractionDynamic loadingStress MechanicalbusinessLocomotionMuscle ContractionComputer Methods in Biomechanics and Biomedical Engineering
researchProduct

Simple equipment to measure biomechanical quantities of muscles and organs which includes a polarity-programmable peak detector

1982

Biomechanical measurements of muscles and organs require appropriate measuring equipment. As far as the static properties are concerned, the excursion of the bender bar of stress should be without force. The bender bar of force, however, ideally should not elongate under load. Because natural frequency is the most important boundary condition, the bender bar should be developed with this in mind. The developed bars imposed an insignificant preload to the muscle or to the organ. The small changes in resistance occurring in the resistance strain gauges affixed to the bars require the use of a highly stable amplifier. A new amplifier was accordingly developed based on the principle of an instr…

EngineeringComputersBar (music)business.industryMusclesAmplifierAcousticsBiomedical EngineeringElectrical engineeringNatural frequencyEquipment DesignPrecision rectifierBiomechanical PhenomenaComputer Science ApplicationsStress (mechanics)AnimalsHumansInstrumentation amplifierAnuraElectronicsbusinessStrain gaugeMuscle ContractionVoltageMedical & Biological Engineering & Computing
researchProduct

Validation of a subject specific 3-actuator torque-driven model in human vertical jumping.

2013

In this study, a forward dynamic subject specific 3-actuator torque-driven model of the human musculoskeletal system was created based on measurements of individual characteristics of a subject. Simulation results were compared with experimental vertical squat jumping with and without adding weights. By analyzing kinematic and kinetic experimental data at the instant of the toe-off for the same initial conditions, it was shown that a simple computer simulation using a suitable cost function could reproduce the real task performed by humans. This investigation is the first step in a wider project that will incorporate elastic components, and that will evaluate the advantages of the individua…

EngineeringLegbusiness.industrySubject specificBiomechanicsExperimental dataTorsoSquatKinematicsmedicine.disease_causeModels BiologicalHuman musculoskeletal systemJumpingmedicine.anatomical_structureTorquemedicineHumansComputer SimulationJointsbusinessActuatorMuscle SkeletalSimulationMuscle ContractionAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
researchProduct

Functional evidence for GABA as modulator of the contractility of the longitudinal muscle in mouse duodenum: Role of GABAA and GABAC receptors

2007

We investigated, in vitro, the effects of gamma-aminobutyric acid (GABA) on the spontaneous mechanical activity of the longitudinal smooth muscle in mouse duodenum. GABA induced an excitatory effect, consisting in an increase in the basal tone, which was antagonized by the GABA(A)-receptor antagonist, bicuculline, potentiated by (1,2,5,6-Tetrahydropyridin-4-yl)methylphosphinic acid hydrate (TPMPA), a GABA(C)-receptor antagonist and it was not affected by phaclofen, a GABA(B)-receptor antagonist. Muscimol, GABA(A) receptor agonist, induced a contractile effect markedly reduced by bicuculline, tetrodotoxin (TTX), hexamethonium and atropine. Cis-4-aminocrotonic acid (CACA), a specific GABA(C) …

GABA receptorsAgonistmedicine.medical_specialtyDuodenumPyridinesmedicine.drug_classIn Vitro TechniquesBicucullineInhibitory postsynaptic potentialSettore BIO/09 - FisiologiaGABAA-rho receptorGABA AntagonistsMiceGABACellular and Molecular Neurosciencechemistry.chemical_compoundPhaclofenReceptors GABAInternal medicineIntestinal motilitymedicineAnimalsDrug InteractionsGABA Agonistsgamma-Aminobutyric AcidPharmacologyDose-Response Relationship DrugMuscimolGABAA receptorCytarabineMuscle SmoothBicucullinePhosphinic AcidsMice Inbred C57BLEndocrinologyReceptors GABA-Bnervous systemchemistryMuscimolCholinergic excitatory nerveNANC inhibitory nerveHexamethoniumMouse duodenumMuscle Contractionmedicine.drugNeuropharmacology
researchProduct

Age-related differences of γ-aminobutyric acid (GABA)ergic transmission in human colonic smooth muscle.

2021

Background: Enteric neurons undergo to functional changes during aging. We investigated the possible age-associated differences in enteric γ-aminobutyric acid (GABA)ergic transmission evaluating function and distribution of GABAergic receptors in human colon. Methods: Mechanical responses to GABA and GABA receptor agonists on slow phasic contractions were examined in vitro as changes in isometric tension in colonic muscle strips from young (<65 years old) and aged patients (>65 years old). GABAergic receptor expression was assessed by quantitative RT-PCR. Key Results: In both preparations GABA induced an excitatory effect, consisting in an increase in the basal tone, antagonized by th…

GABAA receptor subunitmedicine.medical_specialtyAgingintestinal motilityPhysiologyColonReceptor expressionTetrodotoxinGABAB receptorSettore BIO/09 - Fisiologiachemistry.chemical_compoundGABAPhaclofenGABA receptorSettore BIO/13 - Biologia ApplicataInternal medicinemedicineHumansgamma-Aminobutyric AcidAgedEndocrine and Autonomic SystemsGABAA receptorGastroenterologyMuscle SmoothBicucullineReceptors GABA-AEndocrinologyGABAergic receptorsnervous systemMuscimolchemistryReceptors GABA-BGABAergicmedicine.drugMuscle ContractionNeurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society
researchProduct