Search results for "Muscle Contraction"
showing 10 items of 569 documents
Mechanical and electrophysiological effects of cromakalim on the human urinary bladder.
1994
The effects of cromakalim on spontaneous and induced mechanical activity of human detrusor muscle were investigated in vitro. Cromakalim produces a concentration-related decrease of spontaneous as well as carbachol- and K(+)-evoked contractions. This is the first study to utilize the patch clamp technique to elucidate the mechanism of action of cromakalim on human detrusor cells. Cromakalim hyperpolarizes the detrusor cells by increasing the net outward current which is most likely carried by potassium ions. In the human urinary bladder, this effect is mediated by a glibenclamide-sensitive potassium channel, as glibenclamide is able to diminish the relaxant effect of cromakalim and to preve…
Objective, Noninvasive Evaluation of Velopharyngeal Function in Cleft and Noncleft Patients
1998
Objective The purpose of this study was to investigate a new diagnostic method that provides an approach to noninvasive, objective measurement of velopharyngeal movement by acoustic determination of epipharyngeal volume changes with velopharyngeal muscle function. Design This was a case control study, using consecutive samples. Setting This study took place at the Cleft Palate Rehabilitation Center of the University of Mainz, Germany. Patients Subjects were 29 consecutive cleft lip and palate (CLP) patients and 31 controls (21 patients with dysgnathia and 10 healthy volunteers). Intervention A series of transnasal acoustic measurements (pressure wave: 55 dB for 2 milliseconds) of epipharyng…
Trainierte Skelettmuskulatur als Herzmuskelersatz: Ein neues Therapiekonzept
2008
Neuromuscular junction disassembly and muscle fatigue in mice lacking neurotrophin-4
2001
Neurotrophin-4 (NT-4) is produced by slow muscle fibers in an activity-dependent manner and promotes growth and remodeling of adult motorneuron innervation. However, both muscle fibers and motor neurons express NT-4 receptors, suggesting bidirectional NT-4 signaling at the neuromuscular junction. Mice lacking NT-4 displayed enlarged and fragmented neuromuscular junctions with disassembled postsynaptic acetylcholine receptor (AChR) clusters, reduced AChR binding, and acetylcholinesterase activity. Electromyographic responses, posttetanic potentiation, and action potential amplitude were also significantly reduced in muscle fibers from NT-4 knock-out mice. Slow-twitch soleus muscles from thes…
A mixed FES/EMG system for real time analysis of muscular fatigue
2010
International audience; In this article, we present a functional electrical stimulator allowing the extraction in real time of M-wave characteristics from resulting EMG recodings in order to quantify muscle fatigue. This system is composed of three parts. A Labview software managing the stimulation output and electromyogram (EMG) input signal, a hardware part amplifying the output and input signal and a link between the two previous parts which is made up from input/output module (NIdaq USB 6251). In order to characterize the fatigue level, the Continuous Wavelet Transform is applied yielding a local maxima detection. The fatigue is represented on a scale from 0 for a fine shaped muscle to …
A full body musculoskeletal model based on flexible multibody simulation approach utilised in bone strain analysis during human locomotion
2011
Load-induced strains applied to bone can stimulate its development and adaptation. In order to quantify the incident strains within the skeleton, in vivo implementation of strain gauges on the surfaces of bone is typically used. However, in vivo strain measurements require invasive methodology that is challenging and limited to certain regions of superficial bones only such as the anterior surface of the tibia. Based on our previous study [Al Nazer et al. (2008) J Biomech. 41:1036-1043], an alternative numerical approach to analyse in vivo strains based on the flexible multibody simulation approach was proposed. The purpose of this study was to extend the idea of using the flexible multibod…
Simple equipment to measure biomechanical quantities of muscles and organs which includes a polarity-programmable peak detector
1982
Biomechanical measurements of muscles and organs require appropriate measuring equipment. As far as the static properties are concerned, the excursion of the bender bar of stress should be without force. The bender bar of force, however, ideally should not elongate under load. Because natural frequency is the most important boundary condition, the bender bar should be developed with this in mind. The developed bars imposed an insignificant preload to the muscle or to the organ. The small changes in resistance occurring in the resistance strain gauges affixed to the bars require the use of a highly stable amplifier. A new amplifier was accordingly developed based on the principle of an instr…
Validation of a subject specific 3-actuator torque-driven model in human vertical jumping.
2013
In this study, a forward dynamic subject specific 3-actuator torque-driven model of the human musculoskeletal system was created based on measurements of individual characteristics of a subject. Simulation results were compared with experimental vertical squat jumping with and without adding weights. By analyzing kinematic and kinetic experimental data at the instant of the toe-off for the same initial conditions, it was shown that a simple computer simulation using a suitable cost function could reproduce the real task performed by humans. This investigation is the first step in a wider project that will incorporate elastic components, and that will evaluate the advantages of the individua…
Functional evidence for GABA as modulator of the contractility of the longitudinal muscle in mouse duodenum: Role of GABAA and GABAC receptors
2007
We investigated, in vitro, the effects of gamma-aminobutyric acid (GABA) on the spontaneous mechanical activity of the longitudinal smooth muscle in mouse duodenum. GABA induced an excitatory effect, consisting in an increase in the basal tone, which was antagonized by the GABA(A)-receptor antagonist, bicuculline, potentiated by (1,2,5,6-Tetrahydropyridin-4-yl)methylphosphinic acid hydrate (TPMPA), a GABA(C)-receptor antagonist and it was not affected by phaclofen, a GABA(B)-receptor antagonist. Muscimol, GABA(A) receptor agonist, induced a contractile effect markedly reduced by bicuculline, tetrodotoxin (TTX), hexamethonium and atropine. Cis-4-aminocrotonic acid (CACA), a specific GABA(C) …
Age-related differences of γ-aminobutyric acid (GABA)ergic transmission in human colonic smooth muscle.
2021
Background: Enteric neurons undergo to functional changes during aging. We investigated the possible age-associated differences in enteric γ-aminobutyric acid (GABA)ergic transmission evaluating function and distribution of GABAergic receptors in human colon. Methods: Mechanical responses to GABA and GABA receptor agonists on slow phasic contractions were examined in vitro as changes in isometric tension in colonic muscle strips from young (<65 years old) and aged patients (>65 years old). GABAergic receptor expression was assessed by quantitative RT-PCR. Key Results: In both preparations GABA induced an excitatory effect, consisting in an increase in the basal tone, antagonized by th…