Search results for "Musculoskeletal"
showing 10 items of 1714 documents
Evaluation of a Cell-Free Collagen Type I-Based Scaffold for Articular Cartilage Regeneration in an Orthotopic Rat Model.
2020
The management of chondral defects represents a big challenge because of the limited self-healing capacity of cartilage. Many approaches in this field obtained partial satisfactory results. Cartilage tissue engineering, combining innovative scaffolds and stem cells from different sources, emerges as a promising strategy for cartilage regeneration. The aim of this study was to evaluate the capability of a cell-free collagen I-based scaffold to promote cartilaginous repair after orthotopic implantation in vivo. Articular cartilage lesions (ACL) were created at the femoropatellar groove in rat knees and cell free collagen I-based scaffolds (S) were then implanted into right knee defect for the…
Influence of custom-made and prefabricated insoles before and after an intense run
2017
[EN] Each time the foot contacts the ground during running there is a rapid deceleration that results in a shock wave that is transmitted from the foot to the head. The fatigue of the musculoskeletal system during running may decrease the ability of the body to absorb those shock waves and increase the risk of injury. Insoles are commonly prescribed to prevent injuries, and both custom-made and prefabricated insoles have been observed to reduce shock accelerations during running. However, no study to date has included a direct comparison of their behaviour measured over the same group of athletes, and therefore great controversy still exists regarding their effectiveness in reducing impact …
Navigation accuracy after automatic- and hybrid-surface registration in sinus and skull base surgery.
2016
Objective Computer-aided-surgery in ENT surgery is mainly used for sinus surgery but navigation accuracy still reaches its limits for skull base procedures. Knowledge of navigation accuracy in distinct anatomical regions is therefore mandatory. This study examined whether navigation accuracy can be improved in specific anatomical localizations by using hybrid registration technique. Study design Experimental phantom study. Setting Operating room. Subjects and methods The gold standard of screw registration was compared with automatic LED-mask-registration alone, and in combination with additional surface matching. 3D-printer-based skull models with individual fabricated silicone skin were u…
Media use during adolescence: the recommendations of the Italian Pediatric Society
2019
Abstract Background The use of media device, such as smartphone and tablet, is currently increasing, especially among the youngest. Adolescents spend more and more time with their smartphones consulting social media, mainly Facebook, Instagram and Twitter because. Adolescents often feel the necessity to use a media device as a means to construct a social identity and express themselves. For some children, smartphone ownership starts even sooner as young as 7 yrs, according to internet safety experts. Material and methods We analyzed the evidence on media use and its consequences in adolescence. Results In literature, smartphones and tablets use may negatively influences the psychophysical d…
Influence of structure on the tissue dynamics of the human soleus muscle observed in MRI studies during isometric contractions.
2006
This article investigates how the internal structure of muscle and its relationship with tendon and even skeletal structures influence the translation of muscle fiber contractions into movement of a limb. Reconstructions of the anatomy of the human soleus muscle from the Visible Human Dataset (available from the National Library of Medicine), magnetic resonance images (MRI), and cadaver studies revealed a complex 3D connective tissue structure populated with pennate muscle fibers. The posterior aponeurosis and the median septum of the soleus form the insertion of the muscle and are continuous with the Achilles tendon. The distal extremities of the pennate muscle fibers attach to these struc…
Joined effects of pennation angle and tendon compliance on fibre length in isometric contractions: a simulation study.
1998
The main purpose of this study was to investigate the joined behaviours of tendon and pennation angle during maximal isometric contractions. A musculotendon model of the human soleus muscle was simulated as a function of ankle joint position, which determines the soleus length. Analysis of the respective values of tendon length and pennation angle for various musculotendon lengths showed that the primary effects of tendon elasticity and pennation angle variation were to reduce the fibre length variations by absorption of the musculotendon lengthening. The efficiency of this reduction process was the highest at short soleus lengths and principally related to tendon length variations. Finally…
Performance of Radiomics Features in the Quantification of Idiopathic Pulmonary Fibrosis from HRCT.
2020
Background: Our study assesses the diagnostic value of different features extracted from high resolution computed tomography (HRCT) images of patients with idiopathic pulmonary fibrosis. These features are investigated over a range of HRCT lung volume measurements (in Hounsfield Units) for which no prior study has yet been published. In particular, we provide a comparison of their diagnostic value at different Hounsfield Unit (HU) thresholds, including corresponding pulmonary functional tests. Methods: We consider thirty-two patients retrospectively for whom both HRCT examinations and spirometry tests were available. First, we analyse the HRCT histogram to extract quantitative lung fibrosis…
Treatment algorithm for spontaneous spinal infections: A review of the literature
2019
Background: Primary spinal infections are rare pathologies with an estimated incidence of 5% of all osteomyelitis. The diagnosis can be challenging and this might result in a late identification. The etiological diagnosis is the primary concern to determine the most appropriate treatment. The aim of this review article was to identify the importance of a methodological attitude toward accurate and prompt diagnosis using an algorithm to aid on spinal infection management. Methods: A search was done on spinal infection in some databases including PubMed, ISI Web of Knowledge, Google Scholar, Ebsco, Embasco, and Scopus. Results: Literature reveals that on the basis of a clinical suspicion, the…
Effect of a common exercise programme with an individualised progression criterion based on the measurement of neuromuscular capacity versus current …
2021
IntroductionHigh-load resistance training has shown positive effects in pain and function in lower limb tendinopathies. However, some authors suggest that current exercise programmes produce an increase in tolerance to load and exercise in general but without fixing some existing issues in tendinopathy. This may indicate the need to include training aspects not currently taken into account in the current programmes. The main objective of this study will be to compare the effect of a common exercise protocol for the three predominant lower limb tendinopathies (Achilles, patellar and gluteal), based on an individualised control of the dose and training of specific aspects of the neuromuscular…
Differential Enantioselectivity of Murine GlutathioneS-Transferase Isoenzymes in the Glutathione Conjugation ofTrans-3,4-dihydroxy-1,2-oxy- 1,2,3,4-t…
1998
Abstract The kinetics of the glutathione (GSH) conjugation of (+)- and (−)-enantiomers ofanti- as well assyn-3,4-dihydroxy-1,2-oxy-1,2,3,4-tetrahydrobenzo[c]phenanthrene (B[c]PDE) catalyzed by murine GSHS-transferase (GST) isoenzymes has been investigated. Murine GSTs exhibited significant differences in their enantioselectivity toward B[c]PDE stereoisomers. For example, while pi class isoenzyme mGSTP1-1 was virtually inactive toward stereoisomers with 1Sconfiguration [(−)-syn-and (+)-anti-B[c]PDE], these stereoisomers were good substrates for alpha class isoenzyme mGSTA1-2. When GST activity was measured as a function of varying B[c]PDE concentration (10–320 μM) at a fixed saturating conce…