Search results for "Myograph"
showing 10 items of 689 documents
Effect of different ergonomic supports on muscle activity of dentists during posterior composite restoration
2019
BackgroundThe aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks.MethodsA one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability o…
EMG activity of pigeon oesophagus in vivo.
1982
At rest, the pigeon cervical oesophagus, which is entirely smooth muscle, shows electric activity. This activity consists of bursts of spikes with frequency increasing in the oral-aboral direction. The bursts are un-phase locked, and there are no slow waves (E.C.A.). The surgical transection of the oesophageal muscular wall does not affect the electric activity even in a disconnected segment. After asphyxia electric activity persists, whereas the aboral gradient of frequency disappears. Therefore, the electric activity is thought to be myogenic in origin, and the frequency gradient nervous in origin. Atropine and neostigmine administration suggests that the cholinergic system modulates the …
Electrical stimulation of glossopharyngeal nerve and oesophageal EMG response in the pigeon
1985
The effects of the efferent glossopharyngeal nerve stimulation, on EMG activity of the pigeon cervical oesophagus, were studied. In control animals, stimulation caused a biphasic response characterized by an intra-stimulus excitatory component followed by a post-stimulus inhibitory one. The EMG response to glossopharyngeal stimulation appeared simultaneously throughout the cervical oesophagus. A bell-shaped mechanical wave was detected relating to the electrical excitatory component. Atropine administration antagonized the excitatory component, while the inhibitory one persisted. It occurs intra-stimulus, and its duration is increased, compared to control ones. A reduction in the oesophagea…
Primary peristalsis in pigeon cervical oesophagus: two EMG patterns.
1984
Swallowing elicits two propagated EMG peristaltic patterns in pigeon cervical oesophagus: i) "simple" peristaltic pattern and ii) "complex" peristaltic pattern. "Simple" peristaltic pattern is characterized by an intense, long-lasting burst of spikes, high in amplitude with an aboral increasing delay in onset. "Complex" peristaltic pattern presents an early short period of reduction in spontaneous electrical activity, followed by an excitatory period similar to that of "simple" pattern. The early inhibitory component has a very short delay in onset increasing aborally. Atropine abolishes the EMG excitatory component of both patterns, while the inhibitory period persists, showing increased d…
Effects of mixed reality head-mounted glasses during 90 minutes of mental and manual tasks on cognitive and physiological functions
2018
Background We evaluated the effects of a mixed reality (MR) head-mounted deviceon some cognitiveand physiological functions during 90 min tasks in an attempt to determine their safety for workers. Methods A total of 12 volunteers performed 90-min intellectual and manual tasks with and without MR glasses. Balance, Stroop, and memory tests were conducted before, during and after these tasks. Heart rate and electromyographic activity of some muscles were recorded. A survey was used to determine subjective fatigue, pain, or discomfort. Results Balance, heart rate, rate of perceived exertion, memory, and attention were unaffected by wearing MR glasses. Electromyographic activity increased with …
The Application of Machine Learning Algorithms to the Analysis of Electromyographic Patterns From Arthritic Patients
2009
The main aim of our study was to investigate the possibility of applying machine learning techniques to the analysis of electromyographic patterns (EMG) collected from arthritic patients during gait. The EMG recordings were collected from the lower limbs of patients with arthritis and compared with those of healthy subjects (CO) with no musculoskeletal disorder. The study involved subjects suffering from two forms of arthritis, viz, rheumatoid arthritis (RA) and hip osteoarthritis (OA). The analysis of the data was plagued by two problems which frequently render the analysis of this type of data extremely difficult. One was the small number of human subjects that could be included in the in…
Design and validation of a wireless Body Sensor Network for integrated EEG and HD-sEMG acquisitions
2022
Sensorimotor integration is the process through which the human brain plans the motor program execution according to external sources. Within this context, corticomuscular and corticokinematic coherence analyses are common methods to investigate the mechanism underlying the central control of muscle activation. This requires the synchronous acquisition of several physiological signals, including EEG and sEMG. Nevertheless, physical constraints of the current, mostly wired, technologies limit their application in dynamic and naturalistic contexts. In fact, although many efforts were made in the development of biomedical instrumentation for EEG and High Density-surface EMG (HD-sEMG) signal ac…
Acute Metabolic Response, Energy Expenditure, and EMG Activity in Sitting and Standing
2017
Purpose While merely standing up interrupts sedentary behavior, it is important to study acute metabolic responses during single bouts of sitting and standing to understand the physiological processes affecting the health of office workers. Methods Eighteen healthy middle-age women 49.4 ± 7.9 yr old (range: 40–64) with a body mass index of 23.4 ± 2.8 kg·m−2 volunteered for this laboratory-based randomized crossover trial where they performed 2 h desk work in either sitting or standing postures after overnight fasting. Muscle activity (normalized to walking at 5 km·h−1), respiratory gas exchange, and blood samples were assessed after glucose loading (75 g). Results Compared with seated work,…
Basic knowledge of social hierarchies and physiological profile of reared sea bass Dicentrarchus labrax (L.).
2019
The effects of social hierarchies (dominant/subordinate individuals), such as aggressiveness, feeding order, and territoriality, are some of the characteristics used for describing fish behaviour. Social hierarchy patterns are still poorly understood in European-reared sea bass (Dicentrarchus labrax). In this work, we examine the social interactions among captive fish integrating behavioural and physiological profiles. Groups of three fish with EMG (electromyogram) radio transmitters were monitored for two weeks via video recording. Plasma levels of cortisol, glucose, lactate and lysozyme as well as haematological parameters such as haemoglobin, haematocrit and RBCC (red blood cell count) w…
Wearable electromyography recordings during daily life activities in children with cerebral palsy.
2020
To test whether wearable textile electromyography (EMG) recording systems may detect differences in muscle activity levels during daily activities between children with cerebral palsy (CP) and age-matched typically developing children.Wearable textile EMG recording systems were used to obtain leg muscle activity in 10 children with spastic CP (four females, six males; mean age 9y 6mo, standard deviation [SD] 2y 4mo, range: 6-13y; Gross Motor Function Classification System [GMFCS] level I and II) and 11 typically developing children (four females, seven males; mean age 9y 9mo, SD 1y 11mo, 7-12y) at rest and while performing seven daily activities.Children with CP showed significantly lower a…