Search results for "Myograph"

showing 10 items of 689 documents

Muscular Activity of the Posterior Deltoid During Swimming vs. Resistance Exercises on Water and Dry Land

2010

The purpose of this study was to compare muscular activity of the posterior deltoid muscle during three typical aquatic physical conditioning activities. This interpretative case study involved a 23-year-old elite swimmer and athlete. Muscular activity was measured with surface electromyography during swimming crawl at maximum speed, and also while performing horizontal shoulder abduction using elastic band and Hydro-Tone Bells resistance. During the maximum voluntary contraction, we observed what appeared to be meaningful differences between the percentage of muscular activation during the swimming activity and that observed during the elastic band and aquatic resistance exercises (18.72% …

Posterior deltoidmedicine.medical_specialtyDry landmedicine.diagnostic_testPhysical conditioningbusiness.industryMuscle activationPhysical exerciseElectromyographyPhysical strengthPhysical medicine and rehabilitationSprintPhysical therapymedicinebusinesshuman activitiesInternational Journal of Aquatic Research and Education
researchProduct

Proprioceptive Neuromuscular Facilitation for Accessory Respiratory Muscles Training in Patients After Ischemic Stroke

2019

This study focused on how pulmonary function is affected by proprioceptive neuromuscular facilitation (PNF) of accessory respiratory muscles in the chronic post-stroke phase. The study involved patients who had had ischemic stroke 6 months or more before the PNF treatment investigated. The objective was to define the effect of PNF on bioelectrical resting and maximum activity of the accessory muscles. Patients were randomly assigned to PNF treatment and just positioning treatment as a reference for comparison; 30 patients each. Electromyography of accessory muscles was investigated before and after physiotherapeutic treatments. We found that there was a greater reduction in EMG activity in …

Proprioceptive neuromuscular facilitationStrokeAccessory respiratory musclesPulmonary functionElectromyographyRespiration
researchProduct

Differences in cardiorespiratory and neuromuscular responses between voluntary and stimulated contractions of the quadriceps femoris muscle.

2006

The aim of this study was to compare respiratory gas exchange variables and muscle fatigue between equal-intensity (i.e., same force output) electrostimulated and voluntary contractions of the quadriceps muscle (46+/-10% of maximal voluntary force). Twelve healthy men served as volunteers. Oxygen consumption, ventilation and respiratory exchange ratio were recorded during the exercise bouts. Muscle fatigue was quantified as the exercise-induced reduction in maximal voluntary force. The average oxygen consumption (11+/-3 versus 8+/-2 mL min(-1)kg(-1)), ventilation (23+/-4 versus 16+/-2 L min(-1)) and respiratory exchange ratio (0.96+/-0.02 versus 0.85+/-0.01) were significantly higher during…

Pulmonary and Respiratory MedicineAdultMalemedicine.medical_specialtyTime FactorsPhysiologyQuadriceps MuscleOxygen ConsumptionMedicineHumansRespiratory systemRespiratory exchange ratioPhysical Education and TrainingMuscle fatiguebusiness.industryElectromyographyGeneral NeuroscienceRespirationCardiorespiratory fitnessQuadriceps femoris muscleElectric StimulationAnesthesiaMotor unit recruitmentMuscle FatigueBreathingPhysical therapymedicine.symptombusinessMuscle contractionMuscle ContractionRespiratory physiologyneurobiology
researchProduct

Grasp-specific motor resonance is influenced by the visibility of the observed actor

2016

AbstractMotor resonance is the modulation of M1 corticospinal excitability induced by observation of others' actions. Recent brain imaging studies have revealed that viewing videos of grasping actions led to a differential activation of the ventral premotor cortex depending on whether the entire person is viewed versus only their disembodied hand. Here we used transcranial magnetic stimulation (TMS) to examine motor evoked potentials (MEPs) in the first dorsal interosseous (FDI) and abductor digiti minimi (ADM) during observation of videos or static images in which a whole person or merely the hand was seen reaching and grasping a peanut (precision grip) or an apple (whole hand grasp). Part…

Research ReportAdultMalemedicine.medical_specialtyVisual perceptionAdolescentCognitive Neurosciencemedicine.medical_treatmentMovementClinical NeurologyExperimental and Cognitive PsychologyElectromyography050105 experimental psychologyVideosF5cPremotor cortex03 medical and health sciencesYoung Adult0302 clinical medicinePhysical medicine and rehabilitationHand strengthmedicineHumans0501 psychology and cognitive sciencesMuscle SkeletalMirror neuronmedicine.diagnostic_testHand StrengthElectromyography05 social sciencesGRASPMotor CortexAction observationEvoked Potentials MotorHandTranscranial Magnetic StimulationTranscranial magnetic stimulationNeuropsychology and Physiological Psychologymedicine.anatomical_structureMEPsNeurologyFemalePsychologyNeuroscienceMotor resonance030217 neurology & neurosurgeryPsychomotor PerformanceMotor cortexCortex; a Journal Devoted to the Study of the Nervous System and Behavior
researchProduct

Functional evaluation of a “lingual ring” oral device applied on patients affected by temporo-mandibular disorders tmds: A comparative clinical trial

2021

This study aims to evaluate the functional variations of the electromyographic response and clinical symptomatology in TMD patients. This study has been performed and compared before and after the application of a therapeutic protocol based on the use of an oral device working on the proper mandibular repositioning through the proprioceptive-based lingual re-education called “Lingual Ring”. Between January to December 2016, 32 TMD patients have been recruited out of a series of 321 individuals recruited at the Neurosensorial and Motorial Surgery Department, in Palermo (Italy). All the patients underwent the Surface Electromyography (sEMG) of Masseter and Temporal muscles, with different reg…

Ring deviceTechnologyMandibular DisordersQH301-705.5QC1-999Temporomandibular disorders (TMDs)ElectromyographyMuscular pain03 medical and health sciences0302 clinical medicineLingual ringstomatognathic systemCephalalgiaMedicineGeneral Materials ScienceBiology (General)QD1-999InstrumentationbookFluid Flow and Transfer ProcessesOrthodonticsbook.periodicalFunctional evaluationProprioceptionmedicine.diagnostic_testbusiness.industryTPhysicsProcess Chemistry and TechnologyGeneral Engineering030206 dentistryEngineering (General). Civil engineering (General)Computer Science ApplicationsClinical trialChemistrystomatognathic diseasesMedical devicesTA1-2040businessArticular pain030217 neurology & neurosurgery
researchProduct

Extracorporeal Stimulation of Sacral Nerve Roots for Observation of Pelvic Autonomic Nerve Integrity: Description of a Novel Methodological Setup.

2017

Introduction: Neurophysiologic monitoring can improve autonomic nerve sparing during critical phases of rectal cancer surgery. Objectives: To develop a system for extracorporeal stimulation of sacral nerve roots. Methods: Dedicated software controlled a ten-electrode stimulation array by switching between different electrode configurations and current levels. A built-in impedance and current level measurement assessed the effectiveness of current injection. Intra-anal surface electromyography (sEMG) informed on targeting the sacral nerve roots. All tests were performed on five pig specimens. Results: During switching between electrode configurations, the system delivered 100% of the set cur…

SacrumIntraoperative Neurophysiological MonitoringSwineBiomedical EngineeringAnal CanalStimulationElectromyographySignalExtracorporealPelvis03 medical and health sciences0302 clinical medicinemedicineAnimalsAutonomic PathwaysElectrical impedanceAutonomic nervemedicine.diagnostic_testbusiness.industryElectromyographyRectal NeoplasmsElectric StimulationAnode030220 oncology & carcinogenesisSacral nerve030211 gastroenterology & hepatologybusinessSpinal Nerve RootsOrgan Sparing TreatmentsBiomedical engineeringIEEE transactions on bio-medical engineering
researchProduct

Neck and Shoulder Muscle Activation Among Experienced and Inexperienced Pilots in +Gz Exposure

2017

Background The aim of the present study was to compare differences in electromyography (EMG) activation of the neck and shoulder muscles between groups of inexperienced and experienced pilots during controlled +Gz exposure in a centrifuge. Methods The subjects were volunteer cadets (inexperienced group) and lieutenants (experienced group) undergoing their first centrifuge training. The first group did not have any high performance aircraft (HPA) experience, while the latter one had a 1-yr experience of intense flying of HPA. During the centrifuge run, EMG activity was recorded from the left and right shoulder, neck flexor, and neck extensor muscles. Results The pilots without HPA experience…

Shoulderelectromyographymedicine.medical_specialtyhigh performance aircraftCentrifugationHypergravityElectromyographycervical spineYoung Adult03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationNeck MusclesHumHumansMedicine0501 psychology and cognitive sciences050102 behavioral science & comparative psychologyMuscle activityMuscle Skeletalta315VolunteerFinlandmedicine.diagnostic_testbusiness.industry05 social sciences030208 emergency & critical care medicineMuscle activationta3142General MedicineAnatomyShoulder muscleNeck musclesG forcePilotsMilitary PersonnelAerospace MedicineAviation medicinebusinessGravitationAerospace Medicine and Human Performance
researchProduct

Online signal processing of internal anal sphincter activity during pelvic autonomic nerve stimulation: a new method to improve the reliability of in…

2011

Aim  Intra-operative neuromonitoring is increasingly applied in several surgical disciplines and has been introduced to facilitate pelvic autonomic nerve preservation. Nevertheless, it has been considered a questionable tool for the minimization of risk, as the results are variable and might be misleading. The aim of the present experimental study was to develop an intra-operative neuromonitoring system with improved reliability for monitoring pelvic autonomic nerve function. Method  Fifteen pigs underwent low anterior rectal resection with pelvic autonomic nerve preservation. Intra-operative neuromonitoring was performed under autonomic nerve stimulation with observation of electromyograph…

Signal processingAutonomic nerveIntra-operative neuromonitoringmedicine.diagnostic_testbusiness.industryGastroenterologyStimulationElectromyographyFrequency spectrumInternal anal sphincterInterquartile rangeAnesthesiamedicinebusinessColorectal Disease
researchProduct

Transputer-based parallel system for acquisition and on-line analysis of single-fiber electromyographic signals.

1992

Abstract We describe a transputer-based system suitable for accurate measurements of single-fiber electromyographic jitter. It consists of a conventional electromyograph, a home-made interface and a commercially available transputer-based board installed within a PC/AT compatible. Taking advantage of the concurrent operation of two transputer modules, the system features simultaneous data acquisition and statistical signal processing: while data are acquired and analyzed, a real-time visualization of the signal latency and its variability is provided. In the present configuration, the system can acquire and analyze up to 40,000 consecutive action potentials, which can be grouped into up to …

Signal processingComputer scienceElectromyographyTransputerInterface (computing)Real-time computingHealth InformaticsSignal Processing Computer-AssistedSignalComputer Science ApplicationsData acquisitionMicrocomputersEvaluation Studies as TopicHumansDiagnosis Computer-AssistedSmoothingSoftwareStatistical signal processingJitterComputer methods and programs in biomedicine
researchProduct

Rechnerunterstützte Auswertung elektromyographischer und goniometrischer Meßsignale mit statistischen Signalanalyseverfahren

1998

Signal processingmedicine.diagnostic_testComputer scienceGoniometerBiomedical EngineeringmedicineElectromyographySignalBiomedical engineeringBiomedizinische Technik/Biomedical Engineering
researchProduct