Search results for "Myopia"
showing 10 items of 165 documents
Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas.
2015
To evaluate the visual quality results of fitting a corneoscleral contact lens with multiaspheric geometry design (MAGD CScL) in subjects with irregular corneas after laser-assisted in situ keratomileusis (LASIK) surgery.From a database of patients evaluated for scleral contact lenses, we identified those with irregular corneas and visual problems after they underwent LASIK surgery for correcting myopia. They manifested unsatisfactory visual quality with their current contact lenses or glasses. Therefore, a MAGD CScL was fitted and monitored according to standardized fitting methodology. A diagnostic trial set was used in the fitting process. Visual acuity (VA), subjective visual quality (S…
Early clinical outcomes after small incision lenticule extraction surgery (SMILE)
2018
Abstract Purpose Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer ‘all femtosecond laser’ surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Methods Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein en…
Design and Baseline Characteristics of the HELP Study: An Extended and Long-Term Observation of Pathological Myopia in Caucasians.
2017
<b><i>Purpose:</i></b> To assess the natural disease progression of high myopia in Caucasians considered at risk for the development of myopic choroidal neovascularization (mCNV). <b><i>Methods:</i></b> Subjects were recruited in 25 clinical sites between June 2014 and June 2016. Main inclusion criteria included axial length of ≥26 mm, best-corrected visual acuity ≥0.05 decimal equivalent and presence of at least one out of five predefined morphological disease risk criteria. These were (1) subfoveal choroidal thinning &#x3c; 50 µm, (2) enhanced choroidal curvature length &#x3e; 6,300 µm, (3) lacquer cracks, (4) patchy atrophy &#x3…
Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.
2009
PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…
Visual quality differences between orthokeratology and LASIK to compensate low-moderate myopia.
2013
PURPOSE: To assess the differences in visual performance between orthokeratology (ortho-k) and laser in situ keratomileusis (LASIK) for the treatment of low-to-moderate myopia. METHODS: An adaptive optics visual simulator (Imagine Eyes) was used to simulate the wavefront aberration patterns induced by ortho-k and LASIK for low and moderate myopia on 10 healthy eyes. Visual acuity (VA) at 100%, 50%, and 10% contrast levels and contrast sensitivity (CS) at 10, 20 and 25 cycles per degree (cpd) were then measured for 3- and 6-mm pupil sizes. RESULTS: Differences in VA for 3-mm pupil diameter were not found between ortho-k and LASIK. For 6-mm pupil size, LASIK provided significantly better VA v…
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
2005
Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…
Tear film stability over a myopia control contact lens compared to a monofocal design
2021
Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 +/- 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) …
Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens
2009
Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…
Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)
2013
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…
Visual Acuity in Simple Myopic Astigmatism: Influence of Cylinder Axis
2006
Purpose. The relationship between astigmatic refractive errors and their associated visual acuity has been studied in recent years in the context of refractive power space. The influence of the axis of astigmatism remains a matter of controversy. Our goal in this study is to provide additional experimental evidence to clarify this subject. The influence of the simulated axis orientation was compared with other factors that affect visual acuity such as the particular design of the test and the differences between eyes. Methods. Simple myopic astigmatism from 0 to 3.00 D, in steps of 0.25 D, and with five different axes between 0° and 90°, were simulated on four healthy eyes of young observer…