Search results for "N1"
showing 10 items of 806 documents
An assessment of prime‐boost vaccination schedules with AS03A‐adjuvanted prepandemic H5N1 vaccines: a randomized study in European adults
2012
Please cite this paper as: Gillard et al. (2012) An assessment of prime‐boost vaccination schedules with AS03A‐adjuvanted prepandemic H5N1 vaccines: a randomized study in European adults. Influenza and Other Respiratory Viruses DOI: 10.1111/j.1750‐2659.2012.00349.x. Background Long‐term persistence of immune response and safety of an H5N1 prepandemic influenza vaccine adjuvanted with AS03 (an α‐tocopherol oil‐in‐water emulsion‐based adjuvant system) was evaluated using various prime‐boost schedules that mimicked potential pandemic scenarios (NCT00430521). Methods Five hundred and twelve healthy adults aged 18–60 years received primary vaccination with one or two doses (0, 21 days schedule…
Time course of human 40 Hz EEG activity accompanying P3 responses in an auditory oddball paradigm
1997
In order to quantify the time course of auditory P3-related gamma activity, root mean square (RMS) values were calculated from band-filtered (30-45 Hz) target and non-target responses in an auditory oddball experiment. Evoked (phase locked) gamma activity was evaluated from the time domain averages, whereas induced (not necessarily phase locked) activity was analyzed on the basis of single trials. Gamma RMS values were integrated across different time windows, namely the prestimulus, N50/P50, N100, pre P3, P3 and post P3 window. The single trial P3 window hereby was defined by a maximum amplitude criterion. In accordance with other studies, we found a pronounced increase of evoked gamma act…
The auditory N1 suppression rebounds as prediction persists over time
2016
International audience; The predictive coding model of perception proposes that neuronal responses reflect prediction errors. Repeated as well as predicted stimuli trigger suppressed neuronal responses because they are associated with reduced prediction errors. However, many predictable events in our environment are not isolated but sequential, yet there is little empirical evidence documenting how suppressed neuronal responses reflecting reduced prediction errors change in the course of a predictable sequence of events. Here we conceived an auditory electroencephalography (EEG) experiment where prediction persists over series of four tones to allow for the delineation of the dynamics of th…
Somatostatin-producing neuroendocrine tumors of the duodenum and pancreas: incidence, types, biological behavior, association with inherited syndrome…
2008
Somatostatin-producing neuroendocrine tumors (SOM-NETs) of the duodenum and pancreas appear to be heterogeneous. To determine their clinicopathological profiles, respective data were analyzed on a series of 82 duodenal and 541 pancreatic NETs. In addition, the clinical records of 821 patients with duodenal or pancreatic NETs were reviewed for evidence of a somatostatinoma syndrome. Predominant or exclusive expression of somatostatin was found in 21 (26%) duodenal and 21 (4%) pancreatic NETs. They were classified as sporadic (n=31) or neurofibromatosis type 1 (NF1)-associated duodenal NETs (n=3), gangliocytic paragangliomas (GCPGs; n=6), or poorly differentiated neuroendocrine carcinomas (pd…
Low-frequency rTMS inhibitory effects in the primary motor cortex: Insights from TMS-evoked potentials
2014
The neuromodulatory effects of repetitive transcranial magnetic stimulation (rTMS) have been mostly investigated by peripheral motor-evoked potentials (MEPs). New TMS-compatible EEG systems allow a direct investigation of the stimulation effects through the analysis of TMS-evoked potentials (TEPs).We investigated the effects of 1-Hz rTMS over the primary motor cortex (M1) of 15 healthy volunteers on TEP evoked by single pulse TMS over the same area. A second experiment in which rTMS was delivered over the primary visual cortex (V1) of 15 healthy volunteers was conducted to examine the spatial specificity of the effects. Single-pulse TMS evoked four main components: P30, N45, P60 and N100. M…
The processing of mispredicted and unpredicted sensory inputs interact differently with attention
2018
International audience; Prediction and attention are fundamental brain functions in the service of perception. Interestingly, previous investigations found prediction effects independent of attention in some cases but attention-dependent in other cases. The discrepancy might be related to whether the prediction effect was revealed by comparing mis-predicted event (where there is incorrect prediction) or unpredicted event (where there is no precise prediction) against predicted event, which are associated with different precision-weighted prediction error. Here we conducted a joint analysis on four published electroencephalography (EEG) datasets which allow for proper dissociation of mispred…
Are medical residents a "core group" for for future improvement of influenza vaccination coverage in health-care workers? A study among medical resid…
2011
Abstract Despite international recommendations, vaccination coverage among European healthcare workers, including physicians, is widely recognized as unsatisfactory. In order to plan tailored vaccination campaigns and increase future coverage, we investigated reasons for refusing vaccination and determinants associated with influenza vaccine uptake among young health care workers. A survey was carried out during September and October 2010 on medical residents attending post-graduate Schools of the Medical Faculty at the University of Palermo (Italy). Each participant completed an anonymous web-based questionnaire including items on demographic and occupational characteristics, knowledge, at…
Knowledge of and attitudes to influenza vaccination in healthy primary healthcare workers in Spain, 2011-2012
2013
Annual influenza vaccination is recommended for healthcare workers, but many do not follow the recommendation. The objective of this study was to investigate the factors associated with seasonal influenza vaccination in the 2011– 2012 season. We carried out an anonymous web survey of Spanish primary healthcare workers in 2012. Information on vaccination, and knowledge and attitudes about the influenza vaccine was collected. Workers with medical conditions that contraindicated vaccination and those with high risk conditions were excluded. Multivariate analysis was performed using unconditional logistic regression. We included 1,749 workers. The overall vaccination coverage was 50.7% and was …
Score to identify the severity of adult patients with influenza A (H1N1) 2009 virus infection at hospital admission
2012
The objective of this paper was to develop a prognostic index for severe complications among hospitalized patients with influenza A (H1N1) 2009 virus infection. We conducted a prospective observational cohort study of 618 inpatients with 2009 H1N1 virus infection admitted to 36 Spanish hospitals between July 2009 and February 2010. Risk factors evaluated included host-related factors and clinical data at admission. We developed a composite index of severe in-hospital complications (SIHC), which included: mortality, mechanical ventilation, septic shock, acute respiratory distress syndrome, and requirement for resuscitation maneuvers. Six factors were independently associated with SIHC: age >…
Effect of influenza-induced fever on human bioimpedance values.
2015
Background and Aims Bioelectrical impedance analysis (BIA) is a widely used technique to assess body composition and nutritional status. While bioelectrical values are affected by diverse variables, there has been little research on validation of BIA in acute illness, especially to understand prognostic significance. Here we report the use of BIA in acute febrile states induced by influenza. Methods Bioimpedance studies were conducted during an H1N1 influenza A outbreak in Venezuelan Amerindian villages from the Amazonas. Measurements were performed on 52 subjects between 1 and 40 years of age, and 7 children were re-examined after starting Oseltamivir treatment. Bioelectrical Impedance Vec…