Search results for "NICS"

showing 10 items of 15025 documents

A reanalysis of spinal motion during vibration

1987

Calibrated film of the motion of the lumbar spine during vibration was reanalysed, making use of a number of computer based techniques to improve accuracy and reduce measurement noise. The results demonstrated resonant behaviour at about 4 Hz and indicated that at vibration levels of the order of 1 m/s2 there exists bending of the order of 1° (peak to peak) between adjacent vertebrae in the lumbar spine. The bending is complex and involves phase differences along the spine and possibly a rocking motion of the pelvis.

musculoskeletal diseasesPhysicsAcousticsBiomechanicsPhase (waves)Motion (geometry)Physical Therapy Sports Therapy and RehabilitationHuman Factors and ErgonomicsBody movementBendingAnatomymusculoskeletal systemVibrationNoise (electronics)SpineBiomechanical PhenomenaVibrationHumansRachisErgonomics
researchProduct

Numerical experimental analysis of hybrid double lap aluminum-CFRP joints

2015

Abstract Due to their reliability and ease of assembly, both the adhesively bonded and the mechanical joints are commonly used in different fields of modern industrial design and manufacturing, to joint composite materials or composites with metals. As it is well known, adhesively bonded joints are characterized by high stiffness and good fatigue life, although delamination phenomena localized near the free edges may limit their use, especially for applications where corrosive environments and/or moisture can lead to premature failure of the bonding. In these cases, a possible alternative is given by the well-known mechanical joints. On the contrary, these last joints (bolted, riveted) requ…

musculoskeletal diseasesPolymer-matrix composites (PMCs)Materials sciencechemistry.chemical_elementIndustrial and Manufacturing EngineeringJoints/joiningSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineAluminiumRivetComposite materialJoint (geology)Stress concentrationCarbon fiber reinforced polymerbusiness.industryMechanical EngineeringFinite element analysis (FEA)DelaminationHigh stiffnessStructural engineeringchemistryMechanics of MaterialsMechanical jointCeramics and CompositesPolymer-matrix composites (PMCs); Mechanical properties; Finite element analysis (FEA); Joints/joiningbusinessMechanical propertie
researchProduct

Different sitting positions influence cross country sit skiers performance : Sitting position influence on force generation and cycle characteristics

2018

Cross country sit skiing is a Paralympic discipline in which athletes due to physical impairment ski sitting on a sit-ski. The impairment influences performance directly and also through sitting position. Athletes with a better trunk control usually adopt a sitting position called “kneeing” in which the hip joints are higher than the knee joints. In contrast, athletes with high impact of impairment prefer a sitting position called “knee high” in which the hip joints are lower than the knee joints. Able bodied athletes skiing on the ergometer in these two sitting positions showed different performance. However, to the best of authors’ knowledge, no studies have examined performance, force pr…

musculoskeletal diseasesTrunk controlForce generationmedicine.medical_specialtySittingsitting positionbiomechanics03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationmedicineta315paralympialaisetCross countrybiologyAthletesBiomechanicscross country sit skiing030229 sport sciencesmusculoskeletal systemSitting Positionsbiology.organism_classificationvammaisurheiluParalympic sport; Sitting position; Performance; Cross country sit skiing; BiomechanicsPosition (obstetrics)biomekaniikkaparalympic sportPsychologyhuman activities030217 neurology & neurosurgeryperformance
researchProduct

Stiffness and Reinforcement Effect of electrical Resistance Strain Gauges

2007

:  The increasing use of low-modulus materials, on which the reinforcement effect of the electrical resistance strain gauge is not negligible, has re-opened the research interest into this issue. This study deals with the evaluation of stiffness, and of the strain gauge Young's modulus involved in the estimation of both the global and the local reinforcement effect; the relationship between the strain gauge stiffness and the local reinforcement effect is also analysed. In particular, the experimental technique used to determine the stiffness of some commercial strain gauges is described. The results show that the strain gauge stiffness alone does not permit an accurate evaluation of the loc…

musculoskeletal diseasesanimal structuresMaterials sciencebusiness.industryMechanical Engineeringtechnology industry and agricultureModulusStiffnessStructural engineeringequipment and suppliesmusculoskeletal systemexperimental mechanicreinforcement effectSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineElectrical resistance and conductancestrain gaugesMechanics of MaterialsmedicineSettore ING-IND/12 - Misure Meccaniche E Termichemedicine.symptomComposite materialReinforcementbusinessStrain gaugestiffne
researchProduct

AB1057 risk factors associated with different lumbopelvic patterns of movement

2016

Background Rapid flexion movement increases the loading on the spine and it increases the risk of injuries 1 . In asymptomatic subjects lumbar-dominant and pelvis-dominant patterns of movement during trunk flexion have been observed 2,3 . However, little information about lumbar spine kinematics has been provided. Objectives To find out whether exhibiting different lumbopelvic patterns of movement during trunk flexion affects the kinematics of the lumbar spine in terms of velocity of motion. Methods Differential lumbar spine and pelvis angular displacement during the time course of a standardised sagittal trunk flexion from an upright position was recorded with an electromagnetic tracking d…

musculoskeletal diseasesbusiness.industryImmunologyBiomechanicsKinematicsAnatomyTorsomusculoskeletal systemTrunkGeneral Biochemistry Genetics and Molecular BiologySagittal planeLumbarmedicine.anatomical_structureRheumatologymedicineImmunology and AllergyRange of motionbusinessPelvisAnnals of the Rheumatic Diseases
researchProduct

Hip viscosupplementation under ultra-sound guidance riduces NSAID consumption in symptomatic hip osteoarthritis patients in a long follow-up. Data fr…

2011

Introduction: Non-steroidal anti-inflammatory drugs (NSAIDs) consumption is strictly related to a high gastrointestinal and cardiovascular mortality and morbidity rate. Osteoarthritis Research Society International (OARSI) recommendations in patients with symptomatic hip or knee OA stated that NSAIDs should be used at the lowest effective dose but their long-term use should be avoided if possible. OARSI guidelines for the treatment of the hip OA include the use of viscosupplementation, which aims to restore physiological and rheological features of the synovial fluid. Objective: Aim of this multicentric, open and retrospective study is to investigate if NSAID consumption may be reduced by t…

musculoskeletal diseaseshipultrasoundintra-articular injection; nsaid; hyaluronic acid; hip; ultrasound; osteoarthritisAnti-Inflammatory Agents Non-SteroidalMiddle AgedHip viscosupplementation ultra-sound guidanceOsteoarthritis HipInjections Intra-ArticularosteoarthritisSettore MED/33 - Malattie Apparato LocomotoreHumansUltrasonicsRegistriesHyaluronic Acidnsaidintra-articular injectionAgedFollow-Up StudiesPain MeasurementRetrospective StudiesUltrasonography
researchProduct

The distribution of cartilage thickness in the knee-joints of old-aged individuals -- measurement by A-mode ultrasound.

1997

Abstract Objective. To provide data on the normal distribution of cartilage thickness in the knee joints of old-aged individuals. Design. The accuracy and reproducibility of cartilage thickness measurements were evaluated with A-mode ultrasound, and the cartilage thickness distribution was examined throughout both knee joints of nine individuals aged between 62 and 94 yr. Background. Data on the variation of cartilage thickness in the joint surfaces are relevant for the design of computer models of diathrodial joints and for surgical and arthroscopic procedures, particularly the calculation of cartilage material properties from indentation tests. Methods. A 12.5 MHz A-mode ultrasound transd…

musculoskeletal diseasesmedicine.diagnostic_testbusiness.industryCartilageArthroscopyUltrasoundBiophysicsBiomechanicsKnee Jointmedicine.anatomical_structuremedicineOrthopedics and Sports MedicineFemurPatellaTibiabusinessBiomedical engineeringClinical biomechanics (Bristol, Avon)
researchProduct

Speed-Related Energy Flow and Joint Function Change During Human Walking.

2021

During human walking, mechanical energy transfers between segments via joints. Joint mechanics of the human body are coordinated with each other to adapt to speed change. The aim of this study is to analyze the functional behaviors of major joints during walking, and how joints and segments alter walking speed during different periods (collision, rebound, preload, and push-off) of stance phase. In this study, gait experiment was performed with three different self-selected speeds. Mechanical works of joints and segments were determined with collected data. Joint function indices were calculated based on net joint work. The results show that the primary functional behaviors of joints would n…

musculoskeletal diseasesmedicine.medical_specialtyHistologyComputer scienceBiomedical Engineeringhuman walkingBioengineeringenergy flowjoint functionbiomechanics03 medical and health sciences0302 clinical medicineGait (human)Physical medicine and rehabilitationmedicineJoint (geology)Mechanical energyOriginal ResearchWork (physics)BiomechanicsBioengineering and Biotechnologyspeed030229 sport sciencesCollisionPreferred walking speedmedicine.anatomical_structureAnklehuman activities030217 neurology & neurosurgeryTP248.13-248.65BiotechnologyFrontiers in bioengineering and biotechnology
researchProduct

Kinematics of the patellofemoral joint. Investigations on a computer model with reference to patellar fractures.

1990

Patellofemoral kinematics were studied on a computer model. The articulating point of the patella moves from distal to proximal during flexion, until the quadriceps tendon starts to turn around the femur tendo-femoral gliding. The pattern of patellofemoral movement consists of a gliding and rolling component, the latter at its maximum at the beginning of flexion. The pathway of the instant centers of motion moves from dorsal to ventral during flexion. Stress analysis shows that the contact area is at all times the area of maximum bending stress. The distal part of the patella is the part with mechanical stress at all angles of flexion. The conclusions to be drawn for treatment are that frac…

musculoskeletal diseasesmedicine.medical_specialtyKnee Jointmedicine.medical_treatmentMovementKinematicsModels BiologicalFractures BonemedicineInternal fixationHumansOrthopedics and Sports MedicineFemurComputer Simulationbusiness.industryBiomechanicsGeneral MedicineAnatomyPatellamusculoskeletal systemBiomechanical Phenomenamedicine.anatomical_structureOrthopedic surgerySurgeryPatellaQuadriceps tendonContact areabusinessArchives of orthopaedic and trauma surgery
researchProduct

Patient-specific computational evaluation of stiffness distribution in ascending thoracic aortic aneurysm

2021

Quantifying local aortic stiffness properties in vivo is acknowledged as essential to assess the severity of an ascending thoracic aortic aneurysm (ATAA). Recently, the LESI (local extensional stiffness identification) methodology has been established to quantify non-invasively local stiffness properties of ATAAs using electrocardiographic-gated computed tomography (ECG-gated CT) scans. The aim of the current study was to determine the most sensitive markers of local ATAA stiffness estimation with the hypothesis that direct measures of local ATAA stiffness could better detect the high-risk patients. A cohort of 30 patients (12 BAV and 18 TAV) referred for aortic size evaluation by ECG-gated…

musculoskeletal diseasesmedicine.medical_specialtyanimal structuresBicuspid aortic valveExtensional stiffness0206 medical engineeringBiomedical EngineeringBiophysicsHemodynamicsmacromolecular substances02 engineering and technologyPositive correlationThoracic aortic aneurysm03 medical and health sciencesVascular Stiffness0302 clinical medicineBicuspid aortic valveInternal medicinemedicineHumansOrthopedics and Sports MedicineAortic Pulse PressureAortaComputingMilieux_MISCELLANEOUSShear stressAortic Aneurysm Thoracicbusiness.industryRehabilitationHemodynamics[SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]StiffnessPatient specificAscending thoracic aortic aneurysmmedicine.diseaseNoninvasive inverse method020601 biomedical engineeringAortic AneurysmAortic ValveCardiologyAortic stiffnessmedicine.symptombusiness030217 neurology & neurosurgeryJournal of Biomechanics
researchProduct