Search results for "NOISE"
showing 10 items of 1375 documents
Quenching of bandgaps by flow noise.
2009
We report an experimental study of acoustic effects produced by wind impinging on noise barriers based on two‐dimensional sonic crystals with square symmetry. We found that the attenuation strength of sonic‐crystal‐bandgaps decreases for increasing values of low speed. A quenching of the acoustic bandgap appears at a certain speed value that depends of the barrier filling ratio. For increasing values of low speed, the data indicate that the barrier becomes in a sound source because of its interaction with the wind. We conclude that flow noise has paramount importance in designing acoustic barriers based on sonic crystals. [Work supported by Spanish AECI.]
The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.
2011
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…
Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition
2015
CdZnTe detectors are commonly exploited for the detection of gamma rays. However, obtaining mechanical stable, low noise contacts on CdZnTe is still an issue. In particular, ohmic contacts would be preferable for high flux applications. In this work, we show that it is possible to obtain mechanical stable gold contacts by electroless deposition in methanol solution. Moreover, we show that electroless deposited nickel contacts are also mechanical stable and are good candidates for the realization of ohmic contacts on high resistivity CdZnTe crystals.
Optical rogue-wave-like extreme value fluctuations in fiber Raman amplifiers
2008
International audience; We report experimental observation and characterization of rogue wave-like extreme value statistics arising from pump-signal noise transfer in a fiber Raman amplifier. Specifically, by exploiting Raman amplification with an incoherent pump, the amplified signal is shown to develop a series of temporal intensity spikes whose peak power follows a power-law probability distribution. The results are interpreted using a numerical model of the Raman gain process using coupled nonlinear Schrödinger equations, and the numerical model predicts results in good agreement with experiment.
Risonanza stocastica non dinamica in una popolazione di Nezara Viridula (L.)
2009
In questo lavoro viene studiato l’effetto del rumore sul comportamento, durante il periodo di accoppiamento, di individui di Nezara viridula (L.). Analizzando la risposta di insetti maschi a segnali sotto soglia, prodotti da individui di sesso femminile, si osserva, in presenza di una sorgente esterna di rumore bianco Gaussiano, un’attivazione “comportamentale”, con un andamento non monotono in funzione dell’intensit`a di rumore, chiara indicazione della presenza di risonanza stocastica non dinamica. Lo studio `e ripetuto utilizzando una sorgente di rumore colorato. Infine, i risultati sperimentali vengono riprodotti attraverso un modello a soglia “morbida”, in cui la funzione di cross-corr…
Low-Rank Tucker-2 Model for Multi-Subject fMRI Data Decomposition with Spatial Sparsity Constraint
2022
Tucker decomposition can provide an intuitive summary to understand brain function by decomposing multi-subject fMRI data into a core tensor and multiple factor matrices, and was mostly used to extract functional connectivity patterns across time/subjects using orthogonality constraints. However, these algorithms are unsuitable for extracting common spatial and temporal patterns across subjects due to distinct characteristics such as high-level noise. Motivated by a successful application of Tucker decomposition to image denoising and the intrinsic sparsity of spatial activations in fMRI, we propose a low-rank Tucker-2 model with spatial sparsity constraint to analyze multi-subject fMRI dat…
Assessment of the Reliability of the SPAC Method in Urban Areas
2015
We have carried out several long-term measures of seismic noise with triangular arrays of broad-band seismic sensors, to investigate the reliability of the SPAC method in urban areas. We investigate the stationary and anisotropy of the microtremor wave field. We have found that the anisotropy of the microtremor wave field can be evaluated analyzing the HVNSR as function the azimuth. Furthermore, we showed as strong anisotropies in the microtremors are often observable in particular at high frequencies (> 1 Hz). We have verified as microtremors can be difficult to considered as ergodic processes, and for this reason time averaging, also even over a long periods of time, cannot replace an app…
On the stationarity of the horizontal to vertical noise spectral ratio
2015
The Horizontal to Vertical Noise Spectral Ratio (HVNSR) method is nowadays widely used to estimate the resonance frequencies of geological structures. In the HVNSR method, seismic noise is considered as a stationary stochastic process. However, especially in industrialized/urbanized area, this is a very strict assumption seldom occurred. Several sources of noise can generate non stationary and anisotropic microtremor fields. To investigate the stationarity of microtremor, we have carried out several long-term measures of seismic noise with broad-band seismic sensors, in areas where the main source of anthropogenic noise is well known. The signals acquired have been analyzed both in frequenc…
Image-based MRI Gradient Estimation
2017
In order to reduce geometric distortion phenomena in MR images, every MRI system main magnet undergoes a shimming process. Since this process aims at optimizing magnetic field homogeneity within a so-called uniformity sphere, image quality outside this sphere is neglected. Since the fields vary smoothly in space, MR signal-to-noise ratio is still non-zero just outside the uniformity region, but correction of MR image distortion fails due to lack of magnetic field knowledge outside it. We propose a novel algorithm for measuring all the fields involved in the generation of images. Our proposal is based on exploitation of the distortion which can be observed in images of a known phantom. The p…
Measuring investor sentiment in the stock market
2011
Recently, investor sentiment measures have become one of the more widely examined areas in behavioral finance. A number of measures have been developed in the literature without having been fully validated, and therefore leaving in question which measure should be used for empirical exploration. The purpose of this study is to examine the relative performance of a number of popular measures in predicting stock returns and to test the relative efficacy of a hybrid approach. Using a panel of investor sentiment measures, we develop a new measure of sentiment which combines direct and indirect sentiment measures. Our results show that our composite sentiment index affects the returns of stocks …