Search results for "NUtE"

showing 10 items of 121 documents

Effect of pedalling rates on physiological response during endurance cycling

2001

International audience; This study was undertaken to examine the effect of different pedalling cadences upon various physiological responses during endurance cycling exercise. Eight well-trained triathletes cycled three times for 30 min each at an intensity corresponding to 80% of their maximal aerobic power output. The first test was performed at a freely chosen cadence (FCC); two others at FCC-20% and FCC +20%, which corresponded approximately to the range of cadences habitually used by road racing cyclists. The mean (SD) FCC, FCC-20% and FCC + 20% were equal to 86 (4), 69 (3) and 103 (5) rpm respectively. Heart rate (HR), oxygen uptake (VO2), minute ventilation (VE) and respiratory excha…

AdultMalemedicine.medical_specialtyCadencePhysiology[SHS.SPORT.PS]Humanities and Social Sciences/Sport/Sport physiology03 medical and health sciencesOxygen Consumption0302 clinical medicineAnimal scienceHeart RatePhysiology (medical)Heart ratemedicineHumansOrthopedics and Sports MedicinePower outputExerciseRespiratory exchange ratioFatiguePulmonary Gas ExchangeChemistry[ SHS.SPORT.PS ] Humanities and Social Sciences/Sport/Sport physiologyPublic Health Environmental and Occupational Health030229 sport sciencesGeneral MedicineOxygen uptakeBicyclingIntensity (physics)Oxygen uptakeTriathletesPhysical EndurancePhysical therapyCadenceCycling030217 neurology & neurosurgeryRespiratory minute volumeEuropean Journal of Applied Physiology
researchProduct

Human corticotropin-releasing factor (hCRF) is a potent respiratory analeptic. Physiological and clinical aspects.

1986

During intravenous corticotropin-releasing factor stimulation tests we observed a deepening of the tidal volume in 35 patients. To investigate this presumed respiratory stimulation we measured respiratory parameters in 12 healthy male volunteers in a single-blind placebo-controlled trial. The intravenous 60-s infusion of 100 micrograms of human corticotropin-releasing factor induced a very potent respiratory stimulation in every subject: respiratory minute volume (mean +/- S.D.) increased by 81% from 6.319 +/- 0.577 to 11.464 +/- 1.264 liters per min (P less than 0.001), whereas there was only a slight rise in the mean respiratory rate from 12.4 +/- 3.0 to 14.7 +/- 2.7 breaths per min (P le…

AdultMalemedicine.medical_specialtyRespiratory rateCorticotropin-Releasing HormoneBlood PressureHeart RateInternal medicineDrug DiscoveryHeart rateHyperventilationRespirationmedicineTidal VolumeHumansRespiratory systemGenetics (clinical)Tidal volumebusiness.industryRespirationGeneral MedicineCarbon DioxideOxygenEndocrinologyAnalepticAnesthesiaMolecular Medicinemedicine.symptombusinessRespiratory minute volumeKlinische Wochenschrift
researchProduct

Human Corticotropin-Releasing Hormone in Man: Dose-Response of Minute Ventilation and End-Tidal Partial Pressures of Carbon Dioxide and Oxygen*

1987

The respiratory stimulant properties of iv injections of 33, 67, and 100 micrograms synthetic human corticotropin-releasing hormone (hCRH) were studied in 12 normal men in a single blind, placebo-controlled trial. All doses of hCRH induced a respiratory stimulation in every subject, and the stimulation was dose dependent. The onset of respiratory stimulation occurred within 15-30 sec after hCRH infusion was started. Initially, there was an increase in tidal volume (VT), followed by an increase in respiratory rate. The maximum minute ventilation (VE) occurred 60-120 sec after starting the injection. The 33-micrograms hCRH dose induced a 35% increase in VE from 6.3 +/- 0.6 (+/- SD) to 9.7 +/-…

AdultMalemedicine.medical_specialtyRespiratory rateCorticotropin-Releasing HormonePartial PressureEndocrinology Diabetes and MetabolismClinical BiochemistryBlood PressureStimulationPeptide hormoneBiochemistryEndocrinologyDouble-Blind MethodHeart RateInternal medicineHeart rateFlushingmedicineHumansRespiratory systemTidal volumeDose-Response Relationship DrugChemistryRespirationBiochemistry (medical)Carbon DioxideOxygenEndocrinologyAnesthesiaBreathingRespiratory minute volumeThe Journal of Clinical Endocrinology & Metabolism
researchProduct

Information domain analysis of respiratory sinus arrhythmia mechanisms.

2019

Ventilation related heart rate oscillations – respiratory sinus arrhythmia (RSA) – originate in human from several mechanisms. Two most important of them – the central mechanism (direct communication between respiratory and cardiomotor centers), and the peripheral mechanism (ventilation-associated blood pressure changes transferred to heart rate via baroreflex) have been described in previous studies. The major aim of this study was to compare the importance of these mechanisms in the generation of RSA non-invasively during various states by quantifying the strength of the directed interactions between heart rate, systolic blood pressure and respiratory volume signals. Seventy-eight healthy…

AdultMalemedicine.medical_specialtySupine positionAdolescentPhysiologyBlood Pressure030204 cardiovascular system & hematologyBaroreflex03 medical and health sciencesOrthostatic vital signsElectrocardiographyYoung Adult0302 clinical medicineHeart RateInternal medicineHeart ratemedicineHumansInformation measurePhotoplethysmographybusiness.industryHead-up tiltCardio-respiratory couplingCardiorespiratory fitnessGeneral MedicineBaroreflexRespiratory Sinus ArrhythmiaBlood pressureCardiologyBreathingFemalebusiness030217 neurology & neurosurgeryRespiratory minute volumePhysiological research
researchProduct

Cardiorespiratory Changes During Prolonged Downhill Versus Uphill Treadmill Exercise

2020

AbstractOxygen uptake (V̇O2), heart rate (HR), energy cost (EC) and oxygen pulse are lower during downhill compared to level or uphill locomotion. However, a change in oxygen pulse and EC during prolonged grade exercise is not well documented. This study investigated changes in cardiorespiratory responses and EC during 45-min grade exercises. Nine male healthy volunteers randomly ran at 75% HR reserve during 45-min exercise in a level (+1%), uphill (+15%) or downhill (−15%) condition. V̇O2 , minute ventilation (V̇E ) and end-tidal carbon dioxide (PetCO2) were recorded continuously with 5-min averaging between the 10th and 15th min (T1) and 40th and 45th min (T2). For a similar HR (157±3 bpm…

AdultMaletreadmill running - oxygen uptake - uphill - downhill - energy costmedicine.medical_specialtyOxygen pulsePhysical Therapy Sports Therapy and RehabilitationTreadmill exerciseEnvironment030204 cardiovascular system & hematologyRunningYoung Adult03 medical and health sciencesOxygen Consumption0302 clinical medicine[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemHeart RateInternal medicineHeart ratemedicineHumansOrthopedics and Sports MedicinePulsePulmonary Gas Exchangebusiness.industryCardiorespiratory fitness030229 sport sciencesOxygen uptakeBreathingCardiologyEnergy costEnergy MetabolismbusinessRespiratory minute volumeInternational Journal of Sports Medicine
researchProduct

Assessment of maximal handgrip strength: How many attempts are needed?

2017

BACKGROUND: Handgrip strength (HGS) is used to identify individuals with low muscle strength (dynapenia). The influence of the number of attempts on maximal HGS is not yet known and may differ depending on age and health status. This study aimed to assess how many attempts of HGS are required to obtain maximal HGS.METHODS: Three cohorts (939 individuals) differing in age and health status were included. HGS was assessed three times and explored as continuous and dichotomous variable. Paired t-test, intraclass correlation coefficients (ICC) and Bland-Altman analysis were used to test reproducibility of HGS. The number of individuals with misclassified dynapenia at attempts 1 and 2 with respe…

AdultSarcopeniaAdolescentsex differenceHealth Statusadult; aged; aging; Article; cohort analysis; dual energy X ray absorptiometry; dynamometer; female; four minute walk test; geriatric assessment; grip strength; health status; human; major clinical study; male; middle aged; muscle strength; outpatient; priority journal; reproducibility; sarcopenia; sex difference; six minute walk test; walk test; walking speed; X ray bone densitometer; Aged; Geriatric assessment; Muscle strength; Reproducibility of Results; Sarcopeniahealth statuswalking speedArticlesarcopeniaCohort StudiesYoung Adultmalesix minute walk testmiddle aged80 and overHumansfour minute walk testhumanMuscle StrengthreproducibilityGeriatric AssessmentX ray bone densitometerAgedAged 80 and overdual energy X ray absorptiometryHand StrengthMuscle strengthadultwalk testagingAge FactorsReproducibility of ResultsOriginal ArticlesdynamometerMiddle Agedcohort analysismajor clinical studyGeriatric assessmentfemaleCross-Sectional Studiespriority journalgrip strengthoutpatientOriginal Articlelihasvoima
researchProduct

Accuracy of delivered versus preset minute ventilation of portable emergency ventilators.

1989

The accuracy of delivered minute volume (VE) ventilation of portable emergency ventilators (PEV) was evaluated. Five PEV from three manufacturers were adapted to an artificial lung for varying compliance and resistance. Each PEV was tested in the "no airmix" (pure oxygen) and "airmix" (approximately 60% oxygen) setting at different frequencies and VE. Measurement of delivered VE (VEdel) was made using a pneumotachograph and digital integration of the flow values greater than 1 min (maximal error +/- 2%). Maximal inspiratory pressure (Pinsp) was measured with a transducer. Two PEV from one manufacturer produced severe hyperventilation when used at low VE (i.e., in children). Two other PEV fr…

Adultmedicine.medical_specialtyPure oxygenCritical Care and Intensive Care MedicinepCO2Artificial lunglaw.inventionlawHyperventilationmedicineHumansHyperventilationChildVentilators Mechanicalbusiness.industryHypoventilationSurgeryHypoventilationEvaluation Studies as TopicAnesthesiaVentilation (architecture)Arterial bloodmedicine.symptomEmergenciesbusinessRespiratory minute volumeCritical care medicine
researchProduct

STRUMENTI E METODI PER INTEGRARE GLI ASPETTI AMBIENTALI NELLA MANUTENZIONE DEL PATRIMONIO ARCHITETTONICO

2022

La corretta e costante applicazione della manutenzione può assumere un ruolo chiave per garantire la qualità del patrimonio costruito e il soddisfacimento delle più recenti classi di requisiti ambientali. A tal fine, è necessario che le strategie che guidano la programmazione delle attività di manutenzione siano modellate sulle caratteristiche del manufatto in esame. In Italia una larga parte degli edifici risulta edificata prima del 1946 e, molti di questi seppur non strettamente tutelati dalla legge, possono presentare rilevanti caratteri morfologici o costruttivi che vanno opportunamente conservati. La manutenzione, condotta in un’ottica sistemica e multiscalare, comprendendo interventi …

AmbienteBuilt environmentSchoolsSostenibilitàMaintenanceManutenzione programmataManutenzionePatrimonio ArchitettonicoEnvironmentPiano di manutenzioneSettore ICAR/12 - Tecnologia Dell'ArchitetturaScuoleHeritage BuildingAmbiente costruitoSustainabilityPlanned maintenance Maintenance plan
researchProduct

A partire dalla manutenzione: strategie per i siti archeologici

2010

A dieci anni dal Regolamento attuativo della Legge Merloni, il contributo punta ad aggiornare lo stato dell’arte sulla manutenzione dei siti archeologici. Nonostante i numerosi passi avanti, il quadro mostra ancora alcune ambiguità, mentre molti siti continuano a versare in condizioni precarie. La limitatezza delle risorse disponibili, tanto più grave pensando alla vastità del patrimonio culturale, per molto tempo ha costituito un alibi per trascurare la manutenzione. Invece essa costituisce un incentivo per una più efficiente gestione. Si tratta: dell’ambiguità del rapporto manutenzione/conservazione, dei paradossi normativi e dei limiti della programmazione, della specificità della manute…

Archaeological SitesArchitectural HeritageMaintenanceSiti ArcheologiciManutenzionePatrimonio ArchitettonicoGestioneSettore ICAR/12 - Tecnologia Dell'ArchitetturaManagement
researchProduct

Herculaneum Conservation Project

2010

The article describes a modern organizing structure, aimed at Herculaneum preservation and exploitation; this structure, whose approach is international and combined, involves public and private partners as the Soprintendenza Archeologica di Pompei, the Packard Humanities Institute and the British School at Rome.

Archeologia Conservazione Manutenzione.Settore ICAR/12 - Tecnologia Dell'Architettura
researchProduct