Search results for "Neutrons"

showing 10 items of 152 documents

Study of the response of phenol compounds exposed to gamma photons and neutrons for Electron Spin Resonance dosimetry

2014

gamma photons neutrons organic compoundsSettore FIS/01 - Fisica SperimentaleERS dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

SEU characterization of commercial and custom-designed SRAMs based on 90 nm technology and below

2020

International audience; The R2E project at CERN has tested a few commercial SRAMs and a custom-designed SRAM, whose data are complementary to various scientific publications. The experimental data include low- and high-energy protons, heavy ions, thermal, intermediate- and high-energy neutrons, high-energy electrons and high-energy pions.

high-energy protonsCOTS[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]käyttömuistitNuclear TheoryElectronHardware_PERFORMANCEANDRELIABILITY01 natural sciences7. Clean energyIonelektroniikkakomponentitNuclear physicsCross section (physics)Pion0103 physical sciencesNeutronionisoimaton säteilyStatic random-access memory010306 general physicsheavy ionsNuclear Experimentlow-energy protonsPhysicsLarge Hadron Collidercross section010308 nuclear & particles physicsionisoiva säteilyelectronsneutronsmuistit (tietotekniikka)SRAMCharacterization (materials science)säteilyfysiikkapionsSEU
researchProduct

Validation of a method for neutron dosimetry and spectrometry using neutron activation of metal discs

2009

A technique for neutron dosimetry and spectrometry based on neutron activation of different metal discs has been studied. After exposure to a neutron field, the radionuclides produced in the discs are detected using low-level gamma-ray spectrometry and the neutron spectrum is obtained using a spectrum unfolding technique. In order to validate the method, irradiation was performed in a well-characterised (252)Cf neutron reference field. Furthermore, the detector was used to determine the neutron fluence rate and spectrum at a storage place for MOX nuclear fuel. The results of the two measurements are reported and discussed.

inorganic chemicalsMaterials scienceAstrophysics::High Energy Astrophysical PhenomenaNuclear TheoryRadiation DosageMass spectrometryNeutron fluxHumansRadiology Nuclear Medicine and imagingNeutronIrradiationRadiometryNuclear ExperimentMOX fuelNeutronsRadiationintegumentary systemRadiological and Ultrasound TechnologyNuclear fuelbusiness.industryDetectorRadiochemistrytechnology industry and agriculturePublic Health Environmental and Occupational HealthGeneral MedicineSpectrometry GammaMetalsbiological scienceslipids (amino acids peptides and proteins)Nuclear medicinebusinessNeutron activationRadiation Protection Dosimetry
researchProduct

Combined TL and 10B-alanine ESR dosimetry for BNCT

2004

The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with 1 0 B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10 9 to 10 1 4 n t h cm - 2 . The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those…

inorganic chemicalsMaterials scienceBeryllium oxidechemistry.chemical_elementBoron Neutron Capture TherapyRadiationRisk AssessmentSensitivity and SpecificityThermoluminescencelaw.inventiondosimeters electron paramagnetic resonancespin resonancechemistry.chemical_compoundRadiation ProtectionIsotopeslawHumansDosimetryRadiology Nuclear Medicine and imagingBoronElectron paramagnetic resonanceBoronNeutronsRadiationRadiological and Ultrasound Technologybusiness.industryRadiotherapy Planning Computer-AssistedRadiochemistryElectron Spin Resonance SpectroscopyPublic Health Environmental and Occupational HealthReproducibility of ResultsRadiotherapy DosageGeneral MedicineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron temperatureSystems IntegrationNeutron capturechemistryGamma RaysBody BurdenThermoluminescent DosimetryNuclear medicinebusinessRelative Biological EffectivenessRadiation Protection Dosimetry
researchProduct

EPR/ALANINE PELLETS WITH LOW Gd CONTENT FOR NEUTRON DOSIMETRY

2013

This paper reports on results obtained by electron paramagnetic resonance (EPR) measurements and Monte Carlo (MC) simulation on a blend of alanine added with low content of gadolinium oxide (5 % by weight) to improve the sensitivity to thermal neutron without excessively affecting tissue equivalence. The sensitivity is enhanced by this doping procedure of more an order of magnitude. The results are compared with those obtained with the addition of boric acid (50 % by weight) where boron is in its natural isotopic composition in order to produce low-cost EPR dosemeters. The gadolinium addition influences neutron sensitivity more than the boron addition. The presence of additives does not sub…

inorganic chemicalsMaterials scienceGadoliniumAnalytical chemistrychemistry.chemical_elementGadoliniumRadiation Dosagelaw.inventionBoric acidchemistry.chemical_compoundBoric AcidsIsotopeslawRadiology Nuclear Medicine and imagingNeutronIrradiationBoronElectron paramagnetic resonanceRadiometryNeutronsRadiationAlanineRadiological and Ultrasound Technologybusiness.industryElectron paramagnetic resonance (EPR) alanine pellet gadolinium Monte Carlo (MC) simulation dosimetryDopingtechnology industry and agriculturePublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyGeneral MedicineNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryNuclear medicinebusinessMonte Carlo Method
researchProduct

Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field

2007

In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…

inorganic chemicalsMaterials sciencePhotonGadoliniumAnalytical chemistrychemistry.chemical_elementRadiation DosageSensitivity and SpecificityFluencelaw.inventionRadiation ProtectionRadiation MonitoringlawMaterials TestingThermalDosimetryRadiology Nuclear Medicine and imagingNeutronESR Dosimetry BNCTElectron paramagnetic resonanceNeutronsAlanineRadiationRadiological and Ultrasound Technologybusiness.industryElectron Spin Resonance Spectroscopytechnology industry and agriculturePublic Health Environmental and Occupational HealthReproducibility of ResultsEquipment DesignGeneral MedicineNeutron temperatureEquipment Failure AnalysischemistryCalibrationbiological scienceslipids (amino acids peptides and proteins)Nuclear medicinebusinessRadiation Protection Dosimetry
researchProduct

Thermal Properties, Raman Spectroscopy and Tem Images of Neutron-Bombarded Graphite

2013

Neutron-irradiated graphite to a total dose of 3.6 × 1016 n cm−2 was studied by DSC, Raman spectroscopy and transmission electron microscopy (TEM). The Wigner energy of neutron-irradiated graphite was 9.5 J/g as measured by DSC; it was released with an exothermal peak at 220°C. The Raman spectroscopy has confirmed the expected effect caused by neutron irradiation of the graphite substrate. The TEM imaging has shown that neutron-irradiated graphite can be effectively exfoliated by sonication in comparison to pristine graphite, which under similar conditions does not exfoliate at all. The interstitial Frenkel defects in neutron-irradiated graphite are intercalated between the graphene layers …

inorganic chemicalsMaterials scienceSonicationAnalytical chemistrylaw.inventionsymbols.namesakelawneutrons irradiationGeneral Materials ScienceNeutronSettore CHIM/01 - Chimica AnaliticaGraphitePhysical and Theoretical ChemistryWigner effectSettore CHIM/02 - Chimica FisicaWigner energySettore CHIM/03 - Chimica Generale e Inorganicaintegumentary systemGrapheneOrganic ChemistrygrapheneGraphite neutrons irradiation graphene exfoliation Wigner energy Raman spectroscopy TEM imagingtechnology industry and agricultureGraphite neutrons irradiation graphene exfoliation Wigner energy Raman spectroscopyTEM imagingexfoliationExfoliation jointAtomic and Molecular Physics and OpticsTransmission electron microscopyRaman spectroscopyTEM imagingbiological sciencessymbolsGraphitelipids (amino acids peptides and proteins)Raman spectroscopy
researchProduct

A measurement of the neutron to 199Hg magnetic moment ratio

2014

The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30).

inorganic chemicalsNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsNeutron magnetic momentAtomic Physics (physics.atom-ph)Astrophysics::High Energy Astrophysical PhenomenaGyromagnetic ratioFOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesPhysics - Atomic PhysicsNuclear physicsMagnetic momentGyromagnetic ratio0103 physical sciencesAtomNeutron[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Physics::Atomic PhysicsNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentPhysicsCondensed Matter::Quantum Gases[PHYS.PHYS.PHYS-ATOM-PH]Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]Magnetic moment010308 nuclear & particles physicsProton magnetic momenttechnology industry and agricultureQC0793Instrumentation and Detectors (physics.ins-det)Ultracold neutrons; Mercury atoms; Magnetic moment; Gyromagnetic ratioQC0770lcsh:QC1-999Mercury atomsElectric dipole momentbiological sciencesUltracold neutronslipids (amino acids peptides and proteins)Astrophysics::Earth and Planetary AstrophysicsAtomic physicsUltracold neutronslcsh:PhysicsPhysics Letters B
researchProduct

Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz

2010

To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …

inorganic chemicalsPhysics::Instrumentation and DetectorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBoron Neutron Capture TherapyValidation Studies as TopicModels BiologicalIonizing radiationTRIGAHospitals UniversityNuclear ReactorsCell Line TumorGermanyRelative biological effectivenessMedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronNeutronsbusiness.industryRadiotherapy Planning Computer-AssistedRadiochemistryLiver NeoplasmsRadiotherapy DosageHematologyGeneral MedicineHep G2 CellsNeutron temperatureNeutron captureOncologyGamma RaysAbsorbed dosebusinessNuclear medicineColorectal Neoplasms
researchProduct

EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD

2004

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…

inorganic chemicalsSafety ManagementMaterials scienceQuality Assurance Health CareRadiation DosageRisk AssessmentSensitivity and Specificitylaw.inventionRadiation Protectionstomatognathic systemlawNuclear ReactorsRisk FactorsmedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronIrradiationElectron paramagnetic resonanceSpectroscopyRadiometryNeutronsObserver VariationRadiationRadiological and Ultrasound Technologybusiness.industryRadiochemistryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyReproducibility of ResultsGeneral MedicineReference StandardsTooth enamelEPR DOSIMETRY MIXED NEUTRON AND GAMMA RADIATION FIELDstomatognathic diseasesmedicine.anatomical_structureCriticalityGamma RaysAbsorbed doseBody BurdenFranceNuclear medicinebusinessRadioactive Hazard ReleaseRelative Biological Effectiveness
researchProduct