Search results for "Neutrons"
showing 10 items of 152 documents
Study of the response of phenol compounds exposed to gamma photons and neutrons for Electron Spin Resonance dosimetry
2014
SEU characterization of commercial and custom-designed SRAMs based on 90 nm technology and below
2020
International audience; The R2E project at CERN has tested a few commercial SRAMs and a custom-designed SRAM, whose data are complementary to various scientific publications. The experimental data include low- and high-energy protons, heavy ions, thermal, intermediate- and high-energy neutrons, high-energy electrons and high-energy pions.
Validation of a method for neutron dosimetry and spectrometry using neutron activation of metal discs
2009
A technique for neutron dosimetry and spectrometry based on neutron activation of different metal discs has been studied. After exposure to a neutron field, the radionuclides produced in the discs are detected using low-level gamma-ray spectrometry and the neutron spectrum is obtained using a spectrum unfolding technique. In order to validate the method, irradiation was performed in a well-characterised (252)Cf neutron reference field. Furthermore, the detector was used to determine the neutron fluence rate and spectrum at a storage place for MOX nuclear fuel. The results of the two measurements are reported and discussed.
Combined TL and 10B-alanine ESR dosimetry for BNCT
2004
The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with 1 0 B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10 9 to 10 1 4 n t h cm - 2 . The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those…
EPR/ALANINE PELLETS WITH LOW Gd CONTENT FOR NEUTRON DOSIMETRY
2013
This paper reports on results obtained by electron paramagnetic resonance (EPR) measurements and Monte Carlo (MC) simulation on a blend of alanine added with low content of gadolinium oxide (5 % by weight) to improve the sensitivity to thermal neutron without excessively affecting tissue equivalence. The sensitivity is enhanced by this doping procedure of more an order of magnitude. The results are compared with those obtained with the addition of boric acid (50 % by weight) where boron is in its natural isotopic composition in order to produce low-cost EPR dosemeters. The gadolinium addition influences neutron sensitivity more than the boron addition. The presence of additives does not sub…
Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field
2007
In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…
Thermal Properties, Raman Spectroscopy and Tem Images of Neutron-Bombarded Graphite
2013
Neutron-irradiated graphite to a total dose of 3.6 × 1016 n cm−2 was studied by DSC, Raman spectroscopy and transmission electron microscopy (TEM). The Wigner energy of neutron-irradiated graphite was 9.5 J/g as measured by DSC; it was released with an exothermal peak at 220°C. The Raman spectroscopy has confirmed the expected effect caused by neutron irradiation of the graphite substrate. The TEM imaging has shown that neutron-irradiated graphite can be effectively exfoliated by sonication in comparison to pristine graphite, which under similar conditions does not exfoliate at all. The interstitial Frenkel defects in neutron-irradiated graphite are intercalated between the graphene layers …
A measurement of the neutron to 199Hg magnetic moment ratio
2014
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30).
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …
EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD
2004
Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…