The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file

2009

Objectives: Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in-vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file. Study design: Twenty straight and single canals of maxillary central teeth were used. Access cavities were prepared; actual working length were determined and compared with electronic working length obtained by means of apex locator Raypex5 …

OrthodonticsTitaniumElectronic apex locatorComputer scienceSignificant differencefungitechnology industry and agricultureReproducibility of ResultsIn Vitro Techniques:CIENCIAS MÉDICAS [UNESCO]Stainless SteelRoot Canal TherapyOtorhinolaryngologyTooth ApexNickel titaniumNickelUNESCO::CIENCIAS MÉDICASHumansSurgeryGeneral Dentistry
researchProduct

Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study

2021

The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10)

Orthodonticsmedicine.medical_specialtyCyclic stressbusiness.industryRoot canalRGeneral Medicinecyclic fatigueEndodonticsenergy-dispersive X-rayArticleNiTiNiti alloyendodonticscross-section designCross section (physics)medicine.anatomical_structureNickel titaniummedicineEndodontic filesMedicineIn vitro studybusinesscontinuous rotationJournal of Clinical Medicine
researchProduct

Evaluation of the force generated by gradual deflection of 0.016-inch NiTi and stainless steel orthodontic wires in self-ligating metallic and esthet…

2019

Background The purpose of this study was to evaluate the deflection forces of 0.016-inch Nitinol and stainless steel orthodontic wires, in association to different self-ligating brackets. Material and Methods Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10N load cell and ISO 15,841, as a protocol. Eight of these models were prepared, each one for the bonding of each set of self-ligating accessories to be tested: Damon Q, Damon Clear (Ormco), In-Ovation R, In-Ovation C (GAC), BioQuick, QuickClear (Forestadent), SmartClip and Clarity SL (3M). Data were subjected to One-way ANOVA, followed by Tukey tests (P<0.05). Re…

TITÂNIOUniversal testing machineMaterials scienceOrthodontic wireResearchOrthodontics:CIENCIAS MÉDICAS [UNESCO]Load cellDeflection (engineering)Nickel titaniumUNESCO::CIENCIAS MÉDICASComposite materialGradual increaseGeneral Dentistry
researchProduct

Dentinal microcracks after root canal instrumentation using instruments manufactured with different NiTi alloys and the SAF system: A systematic revi…

2021

Aim: The aim of this systematic analysis was to assess the prevalence of dentinal microcracks at various levels (3, 6, and 9 mm from the apex) after using instruments made with conventional, R-Phase, and M-Wire NiTi alloys and the SAF system. Materials and Methods: Electronic searches were conducted in the databases Embase, Cochrane Library, Scopus, PubMed, and Web of Science. To arrange search methods, “MeSH” terms and/or keywords typically associated with the subject were paired with the Boolean operators “AND” and “OR.” Additional searches were conducted on the websites of four separate endodontic journals. After reading the titles and excluding duplicates, 1000 of the 1343 documents ori…

TechnologyMtwo filesWeb of scienceQH301-705.5Computer scienceQC1-9990206 medical engineeringDentistryTF Adaptive files02 engineering and technologyRoot canal instrumentationSystem a03 medical and health sciencesReciproc files0302 clinical medicineSelf-Adjusting File systemGeneral Materials ScienceBiology (General)QD1-999InstrumentationFluid Flow and Transfer ProcessesR-phasebusiness.industryTPhysicsProcess Chemistry and TechnologyGeneral Engineering030206 dentistryWAVEONE filesEngineering (General). Civil engineering (General)ProTaper Next files020601 biomedical engineeringComputer Science ApplicationsChemistryK3XF filesProTaper Universal filesMartensite-wireNickel titaniumDentin microcracksLower prevalenceNiTi instrumentsTA1-2040business
researchProduct

Wear of Ceramic Tools When Working Nickel Based Alloys

1996

In order to improve the toughness of alumina materials, various trials have recently been made. These include toughening by the addition of zirconia and of significant amounts of titanium carbide to ceramic oxide Al2O3 and the more recent use of nitride based ceramics, which have resulted in an increase of fracture toughness and in a significant improvement of ceramic tool performance. Another very recent way of improving ceramic materials consists in adding SiC whiskers to Al2O3 matrix. This composite material is also suitable for machining nickel based alloys. In order to evaluate and to qualify these materials some test cycles have been carried out in continuous cutting conditions, emplo…

ToughnessTitanium carbideMaterials scienceMetallurgyCarbidechemistry.chemical_compoundchemistrySilicon nitrideMachiningNickel titaniumWhiskervisual_artvisual_art.visual_art_mediumCeramic
researchProduct

The influence of NiTi alloy on the cyclic fatigue resistance of endodontic files

2020

Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41)

medicine.medical_specialtyCyclic stressEndodontics.Titanium in Dentistry.Titanio - Aplicaciones en Odontología.Endodoncia.NiTi alloylcsh:Medicine02 engineering and technologyDental metallurgy.ArticleDientes - Cavidades - Preparación.Niti alloy03 medical and health sciencesTeeth - Roots - Planing.0302 clinical medicineCM-Blue WiremedicineEndodontic filesNickel in Dentistry.Statistical analysisDental therapeutics - Equipment and supplies.OrthodonticsTerapéutica dental - Aparatos y material.business.industrylcsh:RAleaciones en odontología.Direct observationAnova test030206 dentistryGeneral Medicine021001 nanoscience & nanotechnologyEndodonticscyclic fatigueNíquel - Aplicaciones en Odontología.endodonticsM-WireNickel titaniumCM-Gold Wire0210 nano-technologybusiness
researchProduct

Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire

2019

Background Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected to cyclic fatigue tests. Material and Methods 40 new NiTi instruments with a length of 25 mm were tested: 20 Wave One Gold Medium (WOG), tip size 35 and variable taper (Dentsply Maillefer, Ballaigues, Switzerland) and 20 Edge One Fire (EOF) (EdgeEndo, Albuquerque, New Mexico) tip size 35 and the same variable taper. A mobile support for the electric handpiece and a stainless-steel block containin…

medicine.medical_specialtyCyclic stressMaterials scienceRoot canal0206 medical engineering02 engineering and technologycyclic fatigue; EdgeOne Fire; endodontics; NiTi; Waveone GoldNiTiOperative Dentistry and Endodontics03 medical and health sciencesReciprocating motion0302 clinical medicinemedicineStatistical analysisGeneral DentistryWaveone GoldOrthodonticsResearchEdgeOne Fire030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Endodonticscyclic fatigue020601 biomedical engineeringendodonticsmedicine.anatomical_structureNickel titaniumUNESCO::CIENCIAS MÉDICASHeat treated
researchProduct

The Effect of surface topographical changes of two different surface treatments rotary instrument

2018

Background One of the major innovations in endodontics has been the introduction of nickel-titanium (NiTi) alloy. This study evaluated the surface topographical changes of two different surface treatments rotary instrument after instrumentation and sterilization. Material and Methods 240 Extracted teeth were included in this study. 90 new AlphaKite and Revo-S NiTi rotary instruments were selected and divided into two groups (Group A 45 AlphaKite and group B 45 Revo-S). Each group were divided into three subgroups: (A1, B1) n=5 files were used as a control, (A2,B2) n=20 files were used to prepare three root canals using endodontic rotary motor then sterilized by autoclave for one cycle under…

medicine.medical_specialtyMaterials scienceScanning electron microscopeResearch030206 dentistry02 engineering and technology021001 nanoscience & nanotechnologyEndodontics:CIENCIAS MÉDICAS [UNESCO]Operative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineMachiningNickel titaniumPhysical vapor depositionUNESCO::CIENCIAS MÉDICASmedicineComposite material0210 nano-technologyGeneral Dentistry
researchProduct

Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system

2016

Background: The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Material and Methods: Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the …

medicine.medical_specialtyRoot canalInstrumentation0206 medical engineeringOdontología02 engineering and technologyOperative Dentistry and Endodontics03 medical and health sciencesFile size0302 clinical medicineConsistency (statistics)medicineGeneral DentistryMathematicsOrthodonticsResearchSignificant difference030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la salud020601 biomedical engineeringSurgerymedicine.anatomical_structureMesiobuccal rootNickel titaniumUNESCO::CIENCIAS MÉDICASJournal of Clinical and Experimental Dentistry
researchProduct