Synergistic combination of polyamide-coated paper-based sorptive phase for the extraction of antibiotics in saliva.

2021

Abstract The development of analytical methods that allow the simultaneous determination of a wide range of analytes with different properties is one of the focuses of attention in Analytical Chemistry. This work describes a proof-of-concept of the synergistic extraction of a planar paper-based sorptive phase modified with a polyamide such as nylon. This as-prepared sorptive phase enables the extraction of six penicillin-derived antibiotics of different polarity from human saliva samples in the same analysis, since the analytes either interact with the paper or with the nylon. The synthesis of the sorptive phase is simple as it only requires dipping the paper into an organic solution of the…

AnalyteBioanalysisFormic acid02 engineering and technology01 natural sciencesBiochemistryMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionDesorptionPhase (matter)Environmental ChemistryHumansSalivaSpectroscopyDetection limitCoated paperChromatographyChemistry010401 analytical chemistryExtraction (chemistry)021001 nanoscience & nanotechnology0104 chemical sciencesAnti-Bacterial AgentsNylons0210 nano-technologyChromatography LiquidAnalytica chimica acta
researchProduct

Analysis of four parabens and bisphenols A, F, S in urine, using dilute and shoot and liquid chromatography coupled to mass spectrometry

2018

Abstract A new strategy for the analysis of 4 parabens (methylparaben, ethyl paraben, propyl paraben and butyl paraben) and 3 bisphenols (A, F and S) in human urine has been developed. Dilute and shoot and liquid chromatography coupled to mass spectrometry (LC-MS/MS) determination was employed. Procedural matched calibration, certified materials and spiked samples were used for validation. The obtained recoveries varied between 85 and 104% with a precision lower than 20% for all analytes. The LOQ was 0.20 ng mL for all analytes. Negative atmospheric pressure chemical ionization in the selected reaction monitoring mode was used for MS detection. The proposed method was successfully applied f…

AnalyteBisphenol AParabensAtmospheric-pressure chemical ionization02 engineering and technologyUrineMass spectrometry01 natural sciencesAnalytical Chemistrychemistry.chemical_compoundPhenolsTandem Mass SpectrometryHumansSulfonesBenzhydryl CompoundsChromatographyMethylparaben010401 analytical chemistrySelected reaction monitoring021001 nanoscience & nanotechnology0104 chemical sciencesParabenchemistrySpain0210 nano-technologyChromatography LiquidTalanta
researchProduct

In tube-solid phase microextraction-nano liquid chromatography: Application to the determination of intact and degraded polar triazines in waters and…

2017

Abstract In-tube solid-phase microextraction (IT-SPME) coupled to miniaturized liquid chromatography (LC) techniques are attractive mainly due to the column efficiency improvement, sensitivity enhancement and reduction of solvent consumption. In addition, the nanomaterials based sorbents can play a key role in the improvement of the extraction efficiency taking into account their interesting physical and chemical properties. Thus, in this work the performance of IT-SPME coupled to nano LC (NanoLC) has been compared with the performance of IT-SPME coupled to capillary LC (CapLC) with similar configurations for the determination of polar triazines including their degradation products. In both…

AnalyteCapillary actionStruviteSurface PropertiesAnalytical chemistry02 engineering and technologySolid-phase microextraction01 natural sciencesBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionPhase (matter)Chromatography High Pressure LiquidSolid Phase MicroextractionChromatographyElutionNanotubes CarbonTriazines010401 analytical chemistryOrganic ChemistryExtraction (chemistry)General Medicine021001 nanoscience & nanotechnology0104 chemical sciencesSolventchemistryStruvite0210 nano-technologyWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Amphetamine-type stimulants analysis in oral fluid based on molecularly imprinting extraction

2018

Abstract A methamphetamine-based molecularly imprinted polymer (MIP) has been prepared by bulk polymerization to recognize new psychoactive substances (NPS) of the amphetamine, cathinones and 2C families in oral fluid samples, being the first precedent of a synthetized MIP for the extraction and preconcentration 32 NPS including amphetamine type substances and synthetic cathinones from oral fluids. Pre-polymerization complex and resulting materials were appropriately characterized by infrared spectroscopy, scanning electron microscopy, and nitrogen adsorption-desorption isotherms. Appropriateness of the material for the specific recognition of the target analytes was also evaluated through …

AnalyteCathinoneIon-mobility spectrometryInfrared spectroscopy02 engineering and technologyChemical FractionationMass spectrometry01 natural sciencesBiochemistryPolymerizationAnalytical ChemistryMolecular ImprintingmedicineHumansEnvironmental ChemistrySolid phase extractionSpectroscopyDetection limitChromatographyChemistrySolid Phase Extraction010401 analytical chemistryMolecularly imprinted polymerGreen Chemistry Technology021001 nanoscience & nanotechnologyBody Fluids0104 chemical sciencesAmphetamineCentral Nervous System StimulantsAdsorption0210 nano-technologymedicine.drugAnalytica Chimica Acta
researchProduct

Quantification of minerals from ATR-FTIR spectra with spectral interferences using the MRC method.

2017

A method for quantifying the individual components of mineral samples based on attenuated total reflectance - Fourier transform infrared spectroscopy (ATR-FTIR) is described, extending the constant ratio (CR) method to analytes absorbing in a common range of wavenumbers. Absorbance values in the spectral region where the analytes absorb relative to the absorbance of an internal standard absorbing at a wavenumber where the analytes do not absorb, permits the quantification of N analytes using measurements at N fixed wavenumbers. The method was tested for mixtures of albite, orthoclase, kaolin and quartz.

AnalyteChemistryAnalytical chemistry02 engineering and technology010501 environmental sciencesengineering.material021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and OpticsAnalytical ChemistryFtir spectraAbsorbanceOrthoclaseAlbiteAttenuated total reflectionengineeringFourier transform infrared spectroscopy0210 nano-technologyInstrumentationQuartzSpectroscopy0105 earth and related environmental sciencesSpectrochimica acta. Part A, Molecular and biomolecular spectroscopy
researchProduct

Gold Nanorods as Plasmonic Sensors for Particle Diffusion.

2016

Plasmonic gold nanoparticles are normally used as sensor to detect analytes permanently bound to their surface. If the interaction between the analyte and the nanosensor surface is negligible, it only diffuses through the sensor’s sensing volume, causing a small temporal shift of the plasmon resonance position. By using a very sensitive and fast detection scheme, we are able to detect these small fluctuations in the plasmon resonance. With the help of a theoretical model consistent with our detection geometry, we determine the analyte’s diffusion coefficient. The method is verified by observing the trends upon changing diffusor size and medium viscosity, and the diffusion coefficients obtai…

AnalyteChemistrybusiness.industryPhysics::OpticsNanoparticleNanotechnology02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesNanosensorColloidal goldOptoelectronicsGeneral Materials SciencePhysical and Theoretical ChemistrySurface plasmon resonanceDiffusion (business)0210 nano-technologybusinessPlasmonLocalized surface plasmonThe journal of physical chemistry letters
researchProduct

Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography

2015

Following the present trends in miniaturization, a methodology that combines on-line In-Tube Solid-Phase Microextraction (IT-SPME) with Liquid Nanochromatography (nano-LC) and UV-vis diode array detection (DAD) was developed. This coupling was achieved by using two interconnected valves (i.e. conventional and micro-automatic valves) in the system of injection. As for IT-SPME, different materials, containing in some cases nanostructures or nanoparticles and in other cases polymeric adsorbent phases immobilized on capillary columns, were tested in order to improve extraction efficiencies of organic compounds; diclofenac was selected as the target analyte. Additionally, the transfer time of th…

AnalyteChromatographyCapillary actionChemistry010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryNanoparticle02 engineering and technologyGeneral Medicine021001 nanoscience & nanotechnologySolid-phase microextraction01 natural sciencesBiochemistryNanostructures0104 chemical sciencesAnalytical ChemistryNanomaterialsAdsorptionMiniaturizationAdsorption0210 nano-technologySolid Phase MicroextractionChromatography LiquidJournal of Chromatography A
researchProduct

In-tube solid phase microextraction coupled to miniaturized liquid chromatography for both, noble metal nanoparticle assessment and sensitive plasmon…

2021

Abstract Colorimetric localized surface plasmon resonance (LSPR) as analytical response is applied for a wide number of chemical sensors and biosensors. However, the dependence of different factors, such as size distribution of nanoparticles (NPs), shape, dielectric environment, inter-particle distance and matrix, among others, can provide non-reliable results by UV–vis spectrometry in complex matrices if NP assessment is not carried out, particularly at low levels of analyte concentrations. Miniaturized liquid chromatography, capillary (CapLC) and nano (NanoLC), coupled on line with in-tube solid phase microextraction (IT-SPME) is proposed for the first time for both, controlling suitabili…

AnalyteChromatographyChemistry010401 analytical chemistryNanoparticle02 engineering and technologyengineering.material021001 nanoscience & nanotechnologyMass spectrometrySolid-phase microextraction01 natural sciencesBiochemistry0104 chemical sciencesAnalytical ChemistryMatrix (chemical analysis)engineeringEnvironmental ChemistryNoble metalSurface plasmon resonance0210 nano-technologyBiosensorSpectroscopyAnalytica chimica acta
researchProduct

Computer simulations for bioequivalence trials: Selection of analyte in BCS class II and IV drugs with first-pass metabolism, two metabolic pathways …

2018

A semi-physiological two compartment pharmacokinetic model with two active metabolites (primary (PM) and secondary metabolites (SM)) with saturable and non-saturable pre-systemic efflux transporter, intestinal and hepatic metabolism has been developed. The aim of this work is to explore in several scenarios which analyte (parent drug or any of the metabolites) is the most sensitive to changes in drug product performance (i.e. differences in in vivo dissolution) and to make recommendations based on the simulations outcome. A total of 128 scenarios (2 Biopharmaceutics Classification System (BCS) drug types, 2 levels of KM Pgp, in 4 metabolic scenarios at 2 dose levels in 4 quality levels of t…

AnalyteCmaxPharmaceutical ScienceAdministration Oral02 engineering and technologyEquivalence Trials as TopicPharmacologyBioequivalence030226 pharmacology & pharmacyModels Biological03 medical and health sciencesFirst pass effect0302 clinical medicinePharmacokineticsHumansComputer SimulationPharmacokineticsIntestinal MucosaBiotransformationChemistryMembrane Transport Proteins021001 nanoscience & nanotechnologyBiopharmaceutics Classification SystemNONMEMNonlinear DynamicsPharmaceutical PreparationsSolubilityTherapeutic EquivalencyResearch DesignArea Under CurveLinear Models0210 nano-technologyMonte Carlo MethodDrug metabolismEuropean journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences
researchProduct

Materials and methods of signal enhancement for spectroscopic whole blood analysis: Novel research overview

2017

Abstract The early diagnosis of diseases is crucial for reducing morbidity and mortality and also for improving the quality of treatment process. Among various biological samples used to follow up the concentrations of disease markers, whole blood sensing can efficiently decrease analysis time by means of introducing methods with no pretreatment. In addition, the direct detection of markers in whole blood facilitates testing procedure and minimize the possibility of the loss of analytes in the process. Therefore, the assay of unprocessed whole blood is becoming increasingly important in clinical diagnostics and biomedical research. Incorporation of new advanced materials plays a major role …

AnalyteComputer science010401 analytical chemistryTreatment processNanotechnology02 engineering and technologyAdvanced materials021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical ChemistrySignal enhancementOptical sensingDisease markers0210 nano-technologySpectroscopyBiomedical engineeringPoint of careWhole bloodTrAC Trends in Analytical Chemistry
researchProduct