Search results for "Nuclear Medicine"
showing 10 items of 3573 documents
Lung density distribution in dynamic CT correlates with oxygenation in ventilated pigs with lavage ARDS † †This study contains parts of the doctoral …
2003
Background Fast dynamic computed tomography (dCT) has been used to assess regional dynamics of lung inflation and deflation processes. The aim of this study was to relate ventilation-induced changes in lung density distribution, as measured over several respiratory cycles by dCT, to oxygenation and shunt fraction in a lavage acute respiratory distress syndrome model. Methods Six anaesthetized pigs underwent pressure-constant ventilation (F I O2=1.0, inspiratory:expiratory ratio=1:1) before and after induction of lung damage by saline lavage. Mean airway pressure ( P a μ w μ ) was varied (8, 13, 18, 23, 28, 33, and 38 cm H2O) in random order. At each P a μ w μ level, dCT acquisitions were pe…
Temporal dynamics of lung aeration determined by dynamic CT in a porcine model of ARDS
2001
We used dynamic CT to identify two different time constants of lung aeration and their individual contribution to the total increase in cross-sectional lung area in healthy and experimentally damaged lungs. In five healthy pigs, inflation and deflation between 0 and 50 cm H2O was imposed during dynamic (250 ms/image) CT acquisition, and repeated after experimental lung injury by saline lavage. The fractional areas of density ranges, which represent aerated lung parenchyma, were determined planimetrically, and their time for expansion during the manoeuvre was fitted using a bi-exponential model. Thus, two compartments, their sizes, i.e. their relative contributions to lung area aerated by th…
Multirotations-CT und ARDS
2001
Purpose Aim of the study was to investigate alveolar inspiration and expiration using multiscan CT. Results of a visual assessment using a scoring system were compared with density ranges known to represent alveolar ventilation best. Method Pigs were examined before and after lavage-induced ARDS. All animals were examined using dynamic multiscan CT. The visual assessment was done by a scoring system proposed by Gattinoni. The results were compared with planimetric determination of defined density ranges. Results In the healthy lung, the visual analysis showed higher scores at lower airway pressures with a marked gradient, whereas at higher pressures neither opacities nor gradients were obse…
Software zur automatischen Quantifizierung von Belüftungszuständen bei akutem Lungenversagen in dynamischen CT-Aufnahmen der Lunge1
2001
Purpose: Density measurements in dynamic CT image series of the lungs allow one to quantify ventilated, hyperinflated, and atelectatic pulmonary compartments with high temporal resolution. Fast automatic segmentation of lung parenchyma and a subsequent evaluation of it's respective density values are a prerequisite for any clinical application of this technique. Material and Methods: For automatic lung segmentation in thoracic CT scans, an algorithm was developed which uses (a) different density masks, and (b) anatomic knowledge to differentiate heart, diaphragm and chest wall from ventilated and atelectatic lung parenchyma. With Animal Care Committee approval, the automated technique was t…
The “central dot sign” in acute epiploic appendagitis
2018
Epiploic appendagitis is the acute inflammation and infarction of epiploic appendages, commonly secondary to torsion. It is a great mimicker as its clinical manifestation may be similar to appendicitis, diverticulitis, or colitis. Focal abdominal pain, tenderness, and mild pyrexia are clinical features of the condition [1]. Epiploic appendages are pedunculated adipose structures which extend from the serosal surface of the colon, along the free taenia and taenia omentalis. They are abundant in the caecum and sigmoid colon and absent in the rectum
Design of a 10 GHz minimum-B quadrupole permanent magnet electron cyclotron resonance ion source
2020
This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the field, affecting the electron heating efficiency, cover a range from 0 to 13 T/m, being similar to conventional ECRIS. Therefore it is expected that the novel ion source produces warm electrons and high charge state ions in significant number. Single electron tracking simulations are used to estim…
Determination of phosphorus by instrumental neutron activation and bremsstrahlung measurement in bone samples
1997
A non destructive method based on the31P(n,γ)32P reaction for the assay of phosphorus in bone samples is described. This method involves a thermal neutron irradiation of 2 minutes in a reactor followed by the measurement of the bremsstrahlung produced by the β− of32P in a Ge-detector surrounded by an anti-Compton shield. Accuracy and precision were tested by analysing the certified NIST 1486 Bone Meal reference material and tri-calcium phosphate (Ca3(PO4)2) samples. The value obtained for the reference material was in good agreement with the certified value and with relative standard deviation of 4.1% the precision was acceptable. The value obtained for Ca3(PO4)2 shows a deviation of −6% fr…
Accurate estimation of retinal vessel width using bagged decision trees and an extended multiresolution Hermite model.
2012
We present an algorithm estimating the width of retinal vessels in fundus camera images. The algorithm uses a novel parametric surface model of the cross-sectional intensities of vessels, and ensembles of bagged decision trees to estimate the local width from the parameters of the best-fit surface. We report comparative tests with REVIEW, currently the public database of reference for retinal width estimation, containing 16 images with 193 annotated vessel segments and 5066 profile points annotated manually by three independent experts. Comparative tests are reported also with our own set of 378 vessel widths selected sparsely in 38 images from the Tayside Scotland diabetic retinopathy scre…
A comparison among different techniques for human ERG signals processing and classification
2014
A comparison among different techniques for human ERG signals processing and classification ( Articles not published yet, but available online Article in press About articles in press (opens in a new window) ) Barraco, R.a, Persano Adorno, D.a , Brai, M.a, Tranchina, L.b a Dipartimento di Fisica e Chimica, Università di Palermo and CNISM, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy b Laboratorio di Fisica e Tecnologie Relative - UniNetLab, Università di Palermo, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy Abstract Feature detection in biomedical signals is crucial for deepening our knowledge about the involved physiological processes. To achieve this aim, many analytic appro…
Archetypal analysis: an alternative to clustering for unsupervised texture segmentation
2019
Texture segmentation is one of the main tasks in image applications, specifically in remote sensing, where the objective is to segment high-resolution images of natural landscapes into different cover types. Often the focus is on the selection of discriminant textural features, and although these are really fundamental, there is another part of the process that is also influential, partitioning different homogeneous textures into groups. A methodology based on archetype analysis (AA) of the local textural measurements is proposed. AA seeks the purest textures in the image and it can find the borders between pure textures, as those regions composed of mixtures of several archetypes. The prop…