Search results for "OPTICS"
showing 10 items of 10033 documents
Application principles of excimer lasers in ophthalmology
2010
Abstract Excimer lasers (193 nm) can be used for photoablation of the human cornea due to their specific physical characteristics. This laser is applied in corneal refractive surgery for the targeted removal of corneal tissue for the purpose of correcting refractive errors. This article provides a short overview of the scientific development of excimer lasers for use in ophthalmic surgery and of the range of applications of these tools.
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…
Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.
2012
PURPOSE: To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. METHODS: Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography…
Influence of the tear film on optical quality of the eye
1997
The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.
Evaluation of Skin Melanoma in Spectral Range 450-950 nm Using Principal Component Analysis
2013
Diagnostic potential of principal component analysis (PCA) of multi-spectral imaging data in the wavelength range 450-950 nm for distant skin melanoma recognition is discussed. Processing of the measured clinical data by means of PCA resulted in clear separation between malignant melanomas and pigmented nevi.
Skin autofluorescence photo-bleaching and photo-memory
2011
Photo-bleaching of in-vivo skin autofluorescence intensity under continuous low power laser irradiation has been studied. Temporal behavior of single-spot fluorescence and spectral fluorescent images have been studied at continuous 405 nm, 473 nm and 532 nm laser excitation and/or pre-irradiation, with power densities well below the laser-skin safety limits. Skin autofluorescence photo-memory effects (laser signatures) have been observed and analyzed, as well.
Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.
2008
Purpose: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure. Methods: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared b…
Broad-beam transmission data for new brachytherapy sources, Tm-170 and Yb-169
2005
The characteristics of the radionuclides (170)Tm and (169)Yb are highly interesting for their use as high dose-rate brachytherapy sources. The introduction of brachytherapy equipment containing these sources will lead to smaller required thicknesses of the materials used in radiation protection barriers compared with the use of conventional sources such as (192)Ir and (137)Cs. The purpose of this study is to determine the required thicknesses of protection material for the design of the protecting walls. Using the Monte Carlo method, transmission data were derived for broad-beam geometries through lead and concrete barriers, from which the first half value layer and tenth value layer are ob…
Skin chromophore mapping by modified video-microscope
2013
Possibilities to map skin chromophores using a modified low-cost digital video-microscope is discussed. The device comprises CMOS digital imaging sensor, four-colour LED illumination system and image acquisition optics. The main goal is to obtain a set of spectral images of the skin area of interest for further conversion into maps of the main skin chromophores
European vestibular experiments on the Spacelab-1 mission: 7. Ocular counterrolling measurements pre- and post-flight.
1986
The static ocular counterrolling (OCR) of the four scientific crew members in the first Spacelab mission was measured during baseline-data-collection before and after the flight of SL-1. It was presumed that the modification of otolithic responses during spaceflight will be reflected in specific changes of the OCR-gain on the first days after recovery. The magnitude of OCR was determined analysing colour-transparencies of subjects right eyes that were produced in different positions of lateral body tilt. In general, one subject did not show any changes at all; three subjects exhibited a significant decrease of OCR-gain after exposure to weightlessness, whereby differences could be found bet…