Search results for "Observer Variation"

showing 10 items of 156 documents

Validation of a computer-assisted system on classifying lower third molars

2010

Objectives: The present study evaluates the reliability of the Radio Memory® software (Radio Memory; Belo Horizonte, Brasil.) on classifying lower third molars, analyzing intra- and interexaminer agreement of the results. Study Design: An observational, descriptive study of 280 lower third molars was made. The corresponding orthopantomographs were analyzed by two examiners using the Radio Memory® software. The exam was repeated 30 days after the first observation by each examiner. Both intra- and interexaminer agreement were determined using the SPSS v 12.0 software package for Windows (SPSS; Chicago, USA). Results: Intra- and interexaminer agreement was shown for both the Pell and Gregory …

Observer VariationMolarWisdom toothbusiness.industryComputer scienceQueixal del senyMandibleDent molar:CIENCIAS MÉDICAS [UNESCO]Software packageMolarSoftwareOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASRadiography PanoramicStatisticsHumansMolar ThirdSurgeryDirect evaluationbusinessGeneral DentistrySoftwareReliability (statistics)
researchProduct

Landmark identification on direct digital versus film-based cephalometric radiographs: A human skull study

2002

The purpose of this study was to investigate differences in landmark identification on vertically scanned, direct digital and conventional (18 x 24 cm) cephalometric radiographs. Eight observers, all orthodontists or postgraduate orthodontic students, recorded 6 landmarks twice on 3 digital and 3 conventional cephalograms obtained from 3 human skulls in a standardized fashion. Digital images were displayed on a 15.1-in TFT monitor in 3:1 mode (20 x 26 cm). Recordings were transferred into standardized coordinate systems and evaluated separately for each coordinate. After correcting for magnification, precision was assessed with Maloney-Rastogi tests, and intraobserver and interobserver repr…

Observer VariationOrthodonticsLandmarkCephalometrybusiness.industryX-Ray FilmRadiographyReproducibility of ResultsMagnificationOrthodonticsContext (language use)Radiography Dental DigitalStatistics NonparametricDigital imageHuman skullmedicine.anatomical_structuremedicineHumansNasionComputer visionArtificial intelligencePosterior nasal spinebusinessMathematicsAmerican Journal of Orthodontics and Dentofacial Orthopedics
researchProduct

Impact of glucuronide interferences on therapeutic drug monitoring of posaconazole by tandem mass spectrometry.

2010

Abstract Background: Posaconazole is a novel antifungal drug for oral application intended especially for therapy of invasive mycoses. Due to variable gastrointestinal absorption, adverse side effects, and suspected drug-drug interactions, therapeutic drug monitoring (TDM) of posaconazole is recommended. Method: A fast ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for quantification of posaconazole with a run-time <3 min was developed and compared to a LC-MS/MS method and HPLC method with fluorescence detection. Results: During evaluation of UPLC-MS/MS, two earlier eluting peaks were observed in the MRM trace of posaconazole. This was only seen in p…

Observer VariationPosaconazoleElectrosprayChromatographyAntifungal Agentsmedicine.diagnostic_testChemistryBiochemistry (medical)Clinical BiochemistryAntifungal drugGeneral MedicineTriazolesMass spectrometryTandem mass spectrometryHigh-performance liquid chromatographyGlucuronidesTherapeutic drug monitoringTandem Mass SpectrometrymedicineHumansDrug MonitoringGlucuronidemedicine.drugClinical chemistry and laboratory medicine
researchProduct

Evaluation of a digital radiography to estimate working length

1997

The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulte…

Observer Variationbusiness.industryDirect methodDentistryRadiography Dental DigitalStatistics NonparametricRoot Canal TherapyIncisorStatistical significanceEndodontic filesOdontometryMedicineCalipersDental Pulp CavityTooth RootbusinessGeneral DentistryDigital radiographyJournal of Endodontics
researchProduct

Validation of short term recall of mobile phone use for the Interphone study

2006

Aim: To validate short term recall of mobile phone use within Interphone, an international collaborative case control study of tumours of the brain, acoustic nerve, and salivary glands related to mobile telephone use. Methods: Mobile phone use of 672 volunteers in 11 countries was recorded by operators or through the use of software modified phones, and compared to use recalled six months later using the Interphone study questionnaire. Agreement between recalled and actual phone use was analysed using both categorical and continuous measures of number and duration of phone calls. Results: Correlations between recalled and actual phone use were moderate to high (ranging from 0.5 to 0.8 acros…

Observer Variationmedicine.medical_specialtyRecallbusiness.industryPublic Health Environmental and Occupational HealthReproducibility of ResultsAudiologyTerm (time)SurgeryCohen's kappaPhoneMobile phoneCase-Control StudiesMental RecallHumansMedicineOriginal ArticleGeometric meanbusinessCategorical variableCell PhoneKappaOccupational and Environmental Medicine
researchProduct

MicroRNAs and their role in the malignant transformation of oral leukoplakia: a scoping review

2021

Background MiRNAs are small non-coding RNAs that regulate gene expression at the post-transcriptional level and have been associated with malignant transformation of oral epithelial precursor lesions such as oral leukoplakia. The aim was to perform a scoping review of the contemporary literature about the different roles of miRNAs during the malignant transformation of oral leukoplakia. Material and Methods We conducted a systematic search with the following MeSH terms: ‘oral leukoplakia’, ‘carcinoma in situ’, ‘microRNAs’, ‘mouth neoplasms’ and ‘epithelial–mesenchymal transition’ in PubMed/MEDLINE, EMBASE and SpringerLink. Results Fifteen articles were included for analysis, among which in …

Oncologymedicine.medical_specialtycone-beam computed tomographyMEDLINEReviewMalignant transformationstomatognathic systemOral Cancer and Potentially malignant disordersInternal medicinemicroRNAmedicineHumansProspective StudiesProspective cohort studyGeneral DentistryUNESCO:CIENCIAS MÉDICASsalivary gland calculiMouth neoplasmMesh termbusiness.industryCarcinoma in situmedicine.diseaseobserver variationOral leukoplakiaMicroRNAsstomatognathic diseasesCell Transformation NeoplasticOtorhinolaryngologyMouth NeoplasmsSurgeryLeukoplakia OralbusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Quality of individually calibrated customary printers for assessment of typical dental diagnoses on glossy paper prints: a multicenter pilot study.

2007

Objective The objective of this study was to compare dental radiographs printed on glossy paper from calibrated low-cost printers with monitor display. Study design Three typical intraoral radiographs were selected and a questionnaire was developed with questions assessing accuracy and subjective quality. A test pattern was designed for printer calibration. After calibration, radiographs were printed on glossy paper with 3 ink-jet and 2 thermo-sublimation printers. Sixteen raters evaluated the printed radiographs, 9 of them also on standardized viewing monitors. Subjective ratings were compared, and an ROC-analysis based on expert-consensus monitor readings was performed. Results Low inter-…

Papermedicine.medical_specialtyComputer sciencemedia_common.quotation_subjectDiagnostic accuracyPilot ProjectsmedicineHumansQuality (business)Medical diagnosisSubjective qualityComputer PeripheralsGeneral Dentistrymedia_commonObserver VariationDiagnosis OralRadiography Dental DigitalSurgeryOtorhinolaryngologyMulticenter studyROC CurveCalibrationOptometryPrintingSurgeryOral SurgeryOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

Assessment of proliferative activity in breast cancer: MIB-1 immunohistochemistry versus mitotic figure count.

1999

Abstract The proliferative activity is one of the most important single prognostic parameters in breast cancer diagnosis and the time-honored measure of proliferative activity, the mitotic figure count, is an integral component of most combined prognostic scores. The detection of the cell cycle-specific antigens Ki-67, and the development of anti-Ki-67 antibodies, including the paraffin-reactive antibody MIB-1, have established immunohistochemical detection of cell cycle-specific antigens as a measure of proliferative activity in breast cancer diagnosis. The current study was performed to correlate mitotic figure counts with the proliferative activity as assessed by MIB-1 immunohistochemist…

Pathologymedicine.medical_specialtyMitotic indexMammary glandBreast NeoplasmsPathology and Forensic MedicineBreast cancermedicineCarcinomaMitotic IndexHumansHigh-power fieldObserver VariationbiologyCarcinoma Ductal BreastNuclear ProteinsAntigens Nuclearmedicine.diseaseImmunohistochemistrymedicine.anatomical_structureKi-67 AntigenKi-67biology.proteinMitotic FigureImmunohistochemistryCell DivisionHuman pathology
researchProduct

Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders

2018

Background/Aims To evaluate the intra- and interrater reliability (I-IR) of sagittal spinopelvic parameters from digital full-spine plain radiographs with basic software tools in an unselected adult population with degenerative spinal complaints who were evaluated for surgery. Methods Forty-nine adult full-spine digital radiographs were measured twice by 3 independent observers, including an experienced spine surgeon, an experienced radiologist, and a resident orthopedic surgeon. Clinical picture archiving and communication system workstations and software tools were used and landmarks were set manually. The I-IR of the sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), …

Pelvic tiltmedicine.medical_specialtyIntraclass correlationradiographic imagediagnostic imagingRadiographyScoliosis/diagnostic imagingskolioosiSurgical planninglcsh:RC346-42903 medical and health sciences0302 clinical medicineselkäsairaudetmedicinestandarditta315lcsh:Neurology. Diseases of the nervous systemOrthodontics030222 orthopedicsscoliosisbusiness.industrysoftwareadultröntgentutkimusta3141RepeatabilitySagittal planeobserver variationInter-rater reliabilitymedicine.anatomical_structurekuvantaminenOrthopedic surgerystandardsSoftware/standardsOriginal ArticleSurgeryNeurology (clinical)reproducibility of resultsbusinessdiagnoosi030217 neurology & neurosurgeryNeurospine
researchProduct

Comparative evaluation of three semi-quantitative radiographic grading techniques for knee osteoarthritis in terms of validity and reproducibility in…

2008

OBJECTIVE: The objective of this work was to compare the measurement properties of three categorical X-ray scoring methods of knee osteoarthritis (OA), both on semiflexed and extended views. METHODS: In data obtained from trials and cohorts, X-rays were graded using Kellgren and Lawrence (KL), the OA Research Society International (OARSI) joint space narrowing score, and measurement of joint space width (JSW). JSW was analyzed as a categorical variable. Construct validity was assessed through logistic regression between X-ray stages and Western Ontario and McMaster Universities OA Index. Inter-observer reliability was assessed in 50 subjects for extended views by weighted kappa. Intra-obser…

Predictive validitymedicine.medical_specialtyDatabases FactualKnee JointPsychometricsJoint replacementmedicine.medical_treatmentBiomedical EngineeringLogistic regressionSeverity of Illness IndexValidity03 medical and health sciences0302 clinical medicineRheumatologyOsteoarthritismedicineHumansOrthopedics and Sports MedicineKneeCategorical variableObserver Variation030203 arthritis & rheumatology030222 orthopedicsProgressionbusiness.industryReproducibility of ResultsConstruct validityIntra-rater reliabilityOsteoarthritis KneeReproducibilityRadiographyInter-rater reliabilityDisease ProgressionPhysical therapybusinessKappa
researchProduct