Towards an international language for incontinence-associated dermatitis (IAD): design and evaluation of psychometric properties of the Ghent Global …
2018
Background Incontinence-associated dermatitis (IAD) is a specific type of irritant contact dermatitis with different levels of severity. An internationally accepted instrument to assess the severity of IAD in adults with established diagnostic accuracy, agreement, and reliability is needed to support clinical practice and research.Objectives To design and psychometrically evaluate the Ghent Global IAD Categorisation Tool (GLOBIAD).Methods The design was based on expert consultation using a three-round Delphi procedure with 34 experts from 13 countries. The instrument was tested using IAD photographs reflecting different severity levels in a sample of 823 health professionals in 30 countries…
Normal reference values of multilayer longitudinal strain according to age decades in a healthy population: A single-centre experience.
2017
Aims Recent advancements in echocardiographic technology allow to analyse myocardial strain in multiple layers. Little is known about the impact of age on layer-specific longitudinal strain in healthy subjects. The aim of this study was to analyse the influence of age on multilayer longitudinal strain and establish normal reference values of layer-specific strain according to age decades in a healthy population referring to our echo laboratory using 2D speckle-tracking echocardiography with layer-specific software. Methods and results Two-hundred sixty-six healthy, consecutive subjects (mean age = 39.2 ± 17.5 years, women/men = 137/129), free of cardiovascular risk factors, were enrolled. S…
Associations between intracranial pressure, intraocular pressure and mean arterial pressure in patients with traumatic and non-traumatic brain injuri…
2008
Introduction: Anatomical proximity of the eye and the intracranial space is a fact but the existence of physiological and pathophysiological relationships between them is elusive. The objective of this study was to explore anatomical and pathophysiological interactions between the eye and the intracranial space and to assess clinical utility of intraocular pressure measurement in estimation of intracranial pressure in patients with brain injuries and to discover how haemodynamic instability could influence these interactions. Controversy surrounds the recent literature concerning this problem and the consensus has not been achieved. Materials and methods: We evaluated the correlation betwee…
Pancreatic cancer detection with magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography: a prospective contro…
2000
Summary Background Magnetic resonance cholangiopancreatography (MRCP) is a non-invasive and increasingly used procedure in cases involving biliary and pancreatic diseases. However, the accuracy of MRCP in differential diagnosis between pancreatic cancer and chronic pancreatitis has never been documented in a large prospective controlled study. Methods 124 patients were recruited for the study, selected from 141 consecutive patients with an average age of 55 years (range 19–80) who presented to our department between February, 1996, and January, 1998, with a strong clinical suspicion of pancreatic cancer. MRCP images were interpreted by a radiologist and a gastroenterologist who were unaware…
Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarth…
2017
Abstract Background The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. Objective To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Design Cross-sectional test-retest design. Method Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correl…
Left ventricular ejection fraction calculation from automatically selected and processed diastolic and systolic frames in short-axis cine-MRI
2005
International audience; Abstract: The calculation of the left ventricular ejection fraction (LVEF) is dependent upon the accurate measurement of diastolic and systolic left ventricular volumes. Although breath-hold cine magnetic resonance imaging (MRI) allows coverage of the whole cardiac cycle with an excellent time resolution, many authors rely on the visual selection of diastolic and the systolic short-axis slices in order to reduce the postprocessing time. An automatic method was developed to detect the endocardial contour on each image, allowing an automatic selection of the systolic frame. The calculated ejection fraction was compared with radionuclide ventriculography (RNV). Sixty-fi…
Inter- and intra-individual variability of paired-pulse curves with transcranial magnetic stimulation (TMS).
2002
Objectives: Previous studies have evaluated the variability of motor thresholds (MTs) and amplitude of motor-evoked potentials (MEPs) to transcranial magnetic stimulation (TMS) within and across individuals. Here we evaluate the reproducibility and inter-hemispheric variability of measures of cortical excitability using the 'conventional' paired-pulse (PP) TMS technique. Methods: We studied PP curves of the left and right hemisphere in 10 healthy subjects on two separate days 2 weeks apart. The inter-stimulus intervals studied were 1, 3, 6, 8, 10 and 12 ms with the conditioning stimulus being 80% of the resting MT, and a single test stimulus producing MEPs of approximately 0.8 mV peak-to-pe…
Blood flow velocity waveforms of the fetal middle cerebral artery in a normal population: reference values from 18 weeks to 42 weeks of gestation
2002
The aim of this prospective cross-sectional study was to establish new Doppler reference curves for peak blood flow velocities (Vmax, Vmean, Vmin) and impedance indices (PI, RI) of the middle cerebral artery at 18-42 weeks of gestation by an automatic wave form analysis integrated into the ultrasound device. In 962 low-risk pregnancies, blood flow velocities were derived from the middle cerebral artery with pulsed color Doppler ultrasonography. Reference curves were constructed for the individual parameters based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square principle for maximum blood flow velocities, as well as on a pol…
Recognition of root canal orifices at a distance – a preliminary study of teledentistry
2011
The remote recognition of root canal orifices was tested on 50 images of endodontically accessed teeth acquired with an intra-oral camera. The images were stored on a laptop computer and were presented to 20 observers who marked the visible canal orifices using software which stored the canal locations in standard files. The marked positions were verified on histological slices. In 87% of the cases, the canal locations were marked correctly. Inter-observer reliability depended on the location of the reviewed root canal (kappa = 0.44–0.77). The detection rate was related to the professional experience of the observers. The maximum proportion of accurate detections was found for the observer…
Quantitative corneal anatomy in emmetropic subjects.
2006
PURPOSE Currently there is little information available about the corneal thickness values of healthy emmetropic subjects. Therefore, the authors decided to analyze the corneal thickness in healthy emmetropic subjects. METHODS The authors analyzed the difference in thickness values between the thinnest corneal site and the central and paracentral cornea in 124 eyes of 124 healthy emmetropic white subjects. RESULTS The mean difference between the thinnest site of the cornea and the thickness values obtained in the areas analyzed was as follows: 12+/-6 microm center; 140+/-19 microm superonasal; 133+/-23 microm nasal; 117+/-26 microm inferonasal; 122+/-19 microm superotemporal ; 89+/-22 micro…