Search results for "Observer Variation"

showing 10 items of 156 documents

Role of Cardiac Magnetic Resonance Imaging in the Detection of Cardiac Amyloidosis

2010

Objectives Our aim was to evaluate the role and mechanism of late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) in identifying cardiac amyloidosis (CA) and to investigate associations between LGE and clinical, morphologic, functional, and biochemical features. Background CA can be challenging to diagnose by echocardiography. Recent studies have demonstrated an emerging role for LGE-CMR. Methods LGE-CMR was performed in 120 patients with amyloidosis. Cardiac histology was available in 35 patients. The remaining 85 patients were divided into those with and without echocardiographic evidence of CA. Results Of the 35 patients with histologically verified CA, abnormal LGE was pre…

Gadolinium DTPAMalemedicine.medical_specialtyPathologymedicine.drug_classBiopsyCardiomyopathyContrast MediaMagnetic Resonance Imaging CineSeverity of Illness IndexElectrocardiographyCardiac magnetic resonance imagingPredictive Value of TestsInternal medicineBiopsymedicineNatriuretic peptideHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAgedRetrospective StudiesUltrasonographyObserver VariationChi-Square Distributionmedicine.diagnostic_testbusiness.industryAmyloidosisMyocardiumReproducibility of ResultsMagnetic resonance imagingAmyloidosisMiddle Agedmedicine.diseasePrognosisSettore MED/11 - Malattie Dell'Apparato CardiovascolareMAGNETIC RESONANCE CARDIAC AMYLOIDOSIS.Early DiagnosisCardiac amyloidosisRadiology Nuclear Medicine and imagingembryonic structurescardiovascular systemCardiologyFemalebusinessCardiomyopathiesCardiology and Cardiovascular MedicineElectrocardiographyBiomarkersJACC: Cardiovascular Imaging
researchProduct

Computer-aided detection of cerebral microbleeds in susceptibility-weighted imaging.

2014

Susceptibility-weighted imaging (SWI) is recognized as the preferred MRI technique for visualizing cerebral vasculature and related pathologies such as cerebral microbleeds (CMBs). Manual identification of CMBs is time-consuming, has limited reliability and reproducibility, and is prone to misinterpretation. In this paper, a novel computer-aided microbleed detection technique based on machine learning is presented: First, spherical-like objects (potential CMB candidates) with their corresponding bounding boxes were detected using a novel multi-scale Laplacian of Gaussian technique. A set of robust 3-dimensional Radon- and Hessian-based shape descriptors within each bounding box were then ex…

Hessian matrixComputer sciencePosterior probabilityHealth InformaticsBlob detectionSensitivity and SpecificityPattern Recognition AutomatedMachine Learningsymbols.namesakeMinimum bounding boxBounding overwatchImage Interpretation Computer-AssistedHumansRadiology Nuclear Medicine and imagingComputer visionComputer SimulationReliability (statistics)Cerebral HemorrhageObserver VariationModels StatisticalRadiological and Ultrasound TechnologyRadon transformbusiness.industryReproducibility of ResultsPattern recognitionImage EnhancementComputer Graphics and Computer-Aided DesignRandom forestDiffusion Magnetic Resonance ImagingData Interpretation StatisticalsymbolsComputer Vision and Pattern RecognitionArtificial intelligencebusinessAlgorithmsMagnetic Resonance AngiographyComputerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
researchProduct

Diagnostic performance and reproducibility of T2w based and diffusion weighted imaging (DWI) based PI-RADSv2 lexicon descriptors for prostate MRI.

2017

To examine the diagnostic performance of PI-RADSv2 T2w and diffusion weighted imaging (DWI) based lexicon descriptors, inter-observer agreement for descriptor assignment and diagnostic accuracy of the PI-RADSv2 assessment categories for multiparametric prostate MRI.176 lesions in 79 consecutive patients are analyzed, lesions are histopathologically verified by MRI-ultrasound fusion biopsy. All lesions are rated according to the PI-RADSv2 lexicon, descriptors for T2w and DWI sequences and resulting assessment categories are assigned by two independent blinded radiologists. We perform receiver-operating-characteristic analysis using the assessment categories. To analyze inter-observer agreeme…

Image-Guided BiopsyMalemedicine.medical_specialtyLexiconMultimodal Imaging030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective StudiesUltrasonographyObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryProstateProstatic NeoplasmsReproducibility of ResultsMagnetic resonance imagingGeneral MedicineMiddle AgedMagnetic Resonance ImagingPI-RADSDiffusion Magnetic Resonance ImagingRadiology Information SystemsROC Curve030220 oncology & carcinogenesisRadiologist 2RadiologybusinessImage-Guided BiopsyKappaDiffusion MRIEuropean journal of radiology
researchProduct

Inter-observer variability of central corneal thickness measurements using non-contact specular microscopy after laser in situ keratomileusis.

2003

BACKGROUND The aim of this study was to investigate the inter-observer variability of central corneal thickness measurements carried out with a non-contact specular microscope in patients who had undergone myopic laser in situ keratomileusis. METHODS Twenty-six eyes of 26 subjects who had undergone myopic laser in situ keratomileusis were studied with the Topcon SP-2000P non-contact specular microscope (Topcon Corp, Tokyo, Japan). The mean of three consecutive measurements of the central corneal thickness was recorded by two investigators prior to and one month after myopic laser in situ keratomileusis. Results obtained by each of the two physicians were compared. RESULTS Prior to surgery t…

In situAdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituKeratomileusislaw.inventionCornealawOphthalmologymedicineMyopiaHumansBody Weights and MeasuresPostoperative PeriodObserver VariationMicroscopyExcimer laserbusiness.industryLASIKLasereye diseasesConfidence intervalOphthalmologySPECULAR MICROSCOPYOptometryFemalesense organsbusinessObserver variationOptometryClinicalexperimental optometry
researchProduct

ETAT: Expository Text Analysis Tool.

2002

Qualitative methods that analyze the coherence of expository texts not only are time consuming, but also present challenges in collecting data on coding reliability. We describe software that analyzes expository texts more rapidly and produces a notable level of objectivity. ETAT (Expository Text Analysis Tool) analyzes the coherence of expository texts. ETAT adopts a symbolic representational system, known as conceptual graph structures. ETAT follows three steps: segmentation of a text into nodes, classification of the unidentified nodes, and linking the nodes with relational arcs. ETAT automatically constructs a graph in the form of nodes and their interrelationships, along with various a…

JavaComputer scienceWritingExperimental and Cognitive Psychologycomputer.software_genreText comprehensionSoftwareMicrocomputersArtificial IntelligenceQuestion answeringSegmentationObjectivity (science)General Psychologycomputer.programming_languageInformation ServicesObserver Variationbusiness.industryReading comprehensionProgramming LanguagesPsychology (miscellaneous)Artificial intelligenceWord ProcessingbusinesscomputerNatural language processingSoftwareCoding (social sciences)Behavior research methods, instruments,computers : a journal of the Psychonomic Society, Inc
researchProduct

A smart and operator independent system to delineate tumours in Positron Emission Tomography scans

2018

Abstract Positron Emission Tomography (PET) imaging has an enormous potential to improve radiation therapy treatment planning offering complementary functional information with respect to other anatomical imaging approaches. The aim of this study is to develop an operator independent, reliable, and clinically feasible system for biological tumour volume delineation from PET images. Under this design hypothesis, we combine several known approaches in an original way to deploy a system with a high level of automation. The proposed system automatically identifies the optimal region of interest around the tumour and performs a slice-by-slice marching local active contour segmentation. It automa…

Lung NeoplasmsComputer sciencemedicine.medical_treatmentPET imagingPattern Recognition Automated030218 nuclear medicine & medical imaging0302 clinical medicineNeoplasmsImage Processing Computer-AssistedSegmentationDiagnosis Computer-AssistedNeoplasm MetastasisRadiation treatment planningSettore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniObserver VariationActive contour modelmedicine.diagnostic_testBrain NeoplasmsPhantoms ImagingComputer Science ApplicationsHead and Neck NeoplasmsPositron emission tomography030220 oncology & carcinogenesis18F-fluoro-2-deoxy-d-glucoseAlgorithms18F-fluoro-2-deoxy-d-glucose and 11C-labeled methionine PET imagingSimilarity (geometry)Health InformaticsSensitivity and SpecificityNOActive contour algorithm03 medical and health sciencesFluorodeoxyglucose F18Predictive Value of TestsRegion of interestmedicineHumansFalse Positive ReactionsRetrospective Studies18F-fluoro-2-deoxy-d-glucose 11C-labeled methionine PET imaging Active contour algorithm Biological target volume Cancer segmentationbusiness.industryRadiotherapy Planning Computer-Assisted11C-labeled methionineReproducibility of ResultsPattern recognitionGold standard (test)Cancer segmentationRadiation therapyBiological target volumePositron-Emission TomographyArtificial intelligenceTomography X-Ray ComputedbusinessSoftwareComputers in Biology and Medicine
researchProduct

A new methodology based on functional principal component analysis tostudy postural stability post-stroke

2018

[EN] Background. A major goal in stroke rehabilitation is the establishment of more effective physical therapy techniques to recover postural stability. Functional Principal Component Analysis provides greater insight into recovery trends. However, when missing values exist, obtaining functional data presents some difficulties. The purpose of this study was to reveal an alternative technique for obtaining the Functional Principal Components without requiring the conversion to functional data beforehand and to investigate this methodology to determine the effect of specific physical therapy techniques in balance recovery trends in elderly subjects with hemiplegia post-stroke. Methods: A rand…

Male030506 rehabilitationmedicine.medical_specialtymedicine.medical_treatmentINGENIERIA MECANICAFunctional Principal Component AnalysisBiophysicsPostural stabilityHemiplegiaTreatment and control groups03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationDouble-Blind MethodRombergmedicineHumansOrthopedics and Sports MedicineLeast-Squares AnalysisPostural BalanceStrokePhysical Therapy ModalitiesAgedBalance (ability)Observer VariationFunctional principal component analysisPrincipal Component AnalysisRehabilitationbusiness.industryPosturographyPosturographyHemodynamicsStroke RehabilitationReproducibility of ResultsMiddle AgedMissing datamedicine.diseaseStrokeTreatment OutcomePrincipal component analysisFemale0305 other medical sciencebusiness030217 neurology & neurosurgery
researchProduct

Evidence of beat perception via purely tactile stimulation

2008

Humans can easily tap in synchrony with an auditory beat but not with an equivalent visual rhythmic sequence, suggesting that the sensation of meter (i.e. of an underlying regular pulse) may be inherently auditory. We assessed whether the perception of meter could also be felt with tactile sensory inputs. We found that, when participants were presented with identical rhythmic sequences filled with either short tones or hand stimulations, they could more efficiently tap in synchrony with strongly rather than weakly metric sequences. These observations suggest that non-musician adults can extract the metric structure of purely tactile rhythms and use it to tap regularly with the beat induced …

MaleAuditory perceptionPeriodicitySensory Receptor CellsMovementmedia_common.quotation_subject[SHS.PSY]Humanities and Social Sciences/PsychologySensory systemNeuropsychological TestsFingers[SHS.PSY] Humanities and Social Sciences/Psychology[ SHS.PSY ] Humanities and Social Sciences/PsychologyRhythmPhysical StimulationPerceptionSensationReaction TimeHumansMuscle SkeletalMolecular Biologymedia_commonObserver VariationCommunicationSensory stimulation therapybusiness.industryMusic psychologyGeneral NeuroscienceTactile perceptionAcoustic StimulationTouchTime PerceptionFemaleNeurology (clinical)businessPsychologyMechanoreceptorsNeuroscienceMusicPsychomotor PerformanceDevelopmental BiologyBrain Research
researchProduct

Development and reliability of a streetscape observation instrument for international use: MAPS-global

2018

Background: Relationships between several built environment factors and physical activity and walking behavior are well established, but internationally-comparable built environment measures are lacking. The Microscale Audit of Pedestrian Streetscapes (MAPS)-Global is an observational measure of detailed streetscape features relevant to physical activity that was developed for international use. This study examined the inter-observer reliability of the instrument in five countries. Methods: MAPS-Global was developed by compiling concepts and items from eight environmental measures relevant to walking and bicycling. Inter-rater reliability data were collected in neighborhoods selected to var…

MaleBuilt environmentGeographic information systemIntraclass correlationMedicine (miscellaneous)ObservationLevel designWalkingMedical and Health Sciences0302 clinical medicineBelgiumResidence Characteristics11. SustainabilityStatisticsMedicine and Health SciencesTOOL030212 general & internal medicineChildVERSIONlcsh:RC620-627Reliability (statistics)Built environmentObserver VariationMeasurementNutrition and Dieteticslcsh:Public aspects of medicineSCIENCESociological Factorslcsh:Nutritional diseases. Deficiency diseasesWalkabilityHong KongFemalePublic HealthPsychologyBrazilAFRICAAdultChinaBehavioural sciencesPhysical Therapy Sports Therapy and RehabilitationWalkabilityEducation03 medical and health sciencesHumansVALIDITYExercisePedestriansbusiness.industryResearchPsychology and Cognitive SciencesAustraliaConstruct validityReproducibility of Resultslcsh:RA1-1270030229 sport sciencesBicyclingPHYSICAL-ACTIVITYMICROSCALE AUDITSpainGeographic Information SystemsEnvironment DesignbusinessInternational Journal of Behavioral Nutrition and Physical Activity
researchProduct

Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary a…

2008

Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…

MaleChest Painmedicine.medical_specialtyCoronary Vessel AnomaliesContrast MediaCoronary AngiographyChest painCoronary artery diseaseElectrocardiographyImaging Three-DimensionalInternal medicineHeart ratePrevalencemedicineHumansRadiology Nuclear Medicine and imagingMultisliceObserver VariationRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle AgedAtenololmedicine.diseaseIopamidolRadiographic Image EnhancementCoronary arteriesmedicine.anatomical_structurecoronary arteryCTCardiologyFemaleRadiologymedicine.symptomTomography X-Ray ComputedbusinessElectrocardiographymedicine.drugArtery
researchProduct