Search results for "Oil Production"
showing 10 items of 59 documents
The Inchworm as a precision translator in a high magnetic field and UHV environment
1989
Abstract A new set-up has been designed and tested for on-line, high-precision mass measurements of short-lived radioactive isotopes via a determination of the ion cyclotron resonance. Ions delivered by the on-line isotope separator ISOLDE at CERN/Geneva are stored in a Penning trap installed in a superconducting solenoid. Due to severe space limitations in the bore of the solenoid, it is impossible to use conventional mechanical feedthroughs for the necessary manipulations inside the uhv chamber. Instead, a number of Inchworms, a high-precision positioning device based on the piezo-electric effect are employed. This publication reports on the first application of this device in a uhv envir…
Multicommutation cold vapour atomic fluorescence determination of Hg in water.
2002
Abstract A multicommutation-based method has been developed for the on-line direct atomic fluorescence spectrometric (AFS) determination of Hg in waters without any previous sample treatment. The performance of the proposed procedure has been compared with that of a conventional AFS system based on continuous mode measurements. In short, the use of multicommutation, together with a reduction of the size of the liquid–gas phase separator, provides an increase of the laboratory productivity by improving the sample throughput by a factor of 3.6 and strongly reduces the sample consumed by a factor of 6 and reagent consumed by a factor of 8.4. The waste generation is reduced by a factor of 2.4 a…
Efficiency of an on-line isotope separator system employing cooled and NaCl-loaded He-jet methods
1976
Abstract A pure helium-jet at liquid nitrogen temperature coupled to a Nielsen type ion source, and a NaCl-loaded helium-jet coupled to a hollow-cathode ion source have been investigated as means to connect a cyclotron target chamber on-line to a mass separator. Technical details and performances of some critical parts of the system are described. Total separation efficiencies measured under various experimental conditions for several nuclides vary between 0.01 and 1.0%.
An on-line mass separator for fission-produced alkali isotopes
1980
Abstract The design of an on-line mass separator installed at the TRIGA reactor in Mainz is described and its performance discussed. A tungsten oven, filled with about 2 g of 235U embedded in graphite, is exposed to a flux of 1.7 × 1011 thermal neutrons (s− cm−2) near the reactor core. After diffusion out of the graphite the fission-produced alkali isotopes are surface-ionized and electromagnetically mass-separated, the resolving power being about 750. Losses during the diffusion out of the target material are discussed. Due to these losses the maximum separator efficiency is about 5%, corresponding to a source strength of about 109 particles s−1 for the most abundant isotopes. The heaviest…
Experimental study of the pyrolysis of waste bitumen for oil production
2020
Abstract This work focuses on bitumen slow pyrolysis. Mass and energy yields of oil, solid and gas were obtained from pyrolysis experiments using a semi-batch reactor in a nitrogen atmosphere, under three non-isothermal conditions (maximum temperature: 450 °C, 500 °C and 550 °C). The effect of temperature on the product yields was discussed. The gas compositions were analysed using gas chromatography (GC) and the heating value of oil and solid residue was also measured. Using a thermo-gravimetric analyser, kinetic parameters were evaluated through Ozawa-Flynn-Wall (OFW) method. Results showed that oil yield is maximum at 500 °C (50%). Moreover, gas yield increased with increasing pyrolysis …
Gas-filled recoil separator for studies of heavy elements
1995
Abstract A gas-filled recoil separator for the study of heavy elements has been constructed. The separator is of type QDQQ with the first, vertically focusing, quadrupole providing improved matching to the acceptance of the dipole magnet. The separator has been designed also for use in vacuum mode in which case a mass resolving power of ≈ 100 is estimated. The deflection angle is 25° and the radius of curvature is 1850 mm. Maximum beam rigidity is 2.2 T m. In the first experiments, new isotopes in the region Z = 85–90 have been synthesized.
Towards on-line production of N=Z94Ag at IGISOL
2008
Abstract A future study of the ground state and low-lying isomeric states of 94 Ag and 96 Ag at the Ion Guide Isotope Separator On-Line (IGISOL) facility, University of Jyvaskyla, requires the development of a low-energy beam of neutron-deficient silver. In order to attain the highest possible extraction efficiencies the coupling of a hot cavity graphite catcher device to the IGISOL mass-separator is planned. A heavy-ion fusion-evaporation reaction will produce the silver recoils which will be captured in the graphite catcher. Resonant laser ionization techniques will be applied to efficiently and selectively ionize the evaporated silver atoms. A simulation program has been written to study…
Status report of the Jyvaskyla ion guide isotope separator on-line facility
1997
The ion guide isotope separator facility IGISOL of the University of Jyvaskyla has been moved to the new K-130 heavy ion cyclotron laboratory. The totally reconstructed facility is described in detail. The primary beams and targets, helium pumping, separator beam line construction and separator beam diagnostics are discussed. The spectroscopy stations are introduced with illustrative examples from the research program, including beta-delayed proton and neutron spectroscopy, gamma-ray spectroscopy with and without arrays, conversion electron spectroscopy, collinear laser spectroscopy and nuclear level lifetime spectroscopy.
The design of a new gas-filled separator at JYFL
2003
Abstract A new gas-filled recoil separator, intended mainly for the study of reaction products in mass region of 100–200 produced in symmetric or nearly symmetric reactions, is under design at the Department of Physics in the University of Jyvaskyla. The separator will be of the type DQQ where a horizontally focusing dipole (D) is followed by a quadrupole (Q) doublet. The bending radius of the dipole magnet will be 1850 mm and the bending angle 50°.
An ion guide for the production of a low energy ion beam of daughter products of α-emitters
2006
A new ion guide has been modeled and tested for the production of a low energy ($\approx$ 40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the $\alpha$-decay of a $^{233}$U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electric fields and helium gas flow transport the ions through an exit hole for injection into a mass separator. Ion guide efficiencies for the extraction of $^{229}$Th$^{+}$ (0.06%), $^{221}$Fr$^{+}$ (6%), and $^{217}$At$^{+}$ (6%) beams have been measured. A detailed study of the electric field and …