Search results for "Operating point"
showing 10 items of 16 documents
Parallel distributed compensation for voltage controlled active magnetic bearing system using integral fuzzy model
2018
Parallel Distributed Compensation (PDC) for current-controlled Active Magnetic Bearing System (AMBS) has been quite effective in recent years. However, this method does not take into account the dynamics associated with the electromagnet. This limits the method to smaller scale applications where the electromagnet dynamics can be neglected. Voltage-controlled AMBS is used to overcome this limitation but this comes with serious challenges such as complex mathematical modelling and higher order system control. In this work, a PDC with integral part is proposed for position and input tracking control of voltage-controlled AMBS. PDC method is based on nonlinear Takagi-Sugeno (T-S) fuzzy model. …
Optimal Placements of SVC Devices in Low Voltage Grids with High Penetration of PV Systems
2018
With the increase of load demand and distributed photovoltaic (PV) systems on the electric grid, maintaining the required voltage tolerance at the point delivery (customer homes/businesses) is becoming more challenging for electric power utilities. In a residential neighborhood, the peak load typically occurs in the early evening hours while maximum PV generation occurs during mid day. As a result, the lowest voltage operating points occur in the evening hours; whereas the highest voltage operating point occur during the day, when the PV systems are injecting more power than what is locally consumed. Static VAR Compensators (SVCs) can be used to mitigate voltage violations and smooth out th…
Optimal power flow for technically feasible energy management systems in islanded microgrids
2016
This paper presents a combined optimal energy and power flow management for islanded microgrids. The highest control level in this case will provide a feasible and optimized operating point around the economic optimum. In order to account for both unbalanced and balanced loads, the optimal power flow is carried out using a Glow-worm Swarm Optimizer. The control level is organized into two different sub-levels, the highest of which accounts for minimum cost operation and the lowest one solving the optimal power flow and devising the set points of inverter interfaced generation units and rotating machines with a minimum power loss. A test has been carried out for 6 bus islanded microgrids to …
Optimal Operating Point Calculation for Medium Voltage Distribution Systems
2007
The paper deals with the calculation of the optimal working point of a distribution system, equipped with several distributed generators, able to operate also autonomously, i.e. disconnected from the main grid. When connected to the main grid, it appears in general convenient to assign the slack bus role to the bus that represents such a connection. The problem becomes more complex when maximum power transfer constraints through the connection must be taken into account. The adequate slack bus treatment is even more important when the optimal operating condition must refer to the condition subsequent to an intentional or unintentional disconnection from the main grid. The paper presents an …
Performances Comparison for a Rotating Shaft Suspended by 4-Axis Radial Active Magnetic Bearings via 𝜇 -Synthesis, Loop-Shaping Design, and Sub ( 𝐻…
2011
The control systems applied on active magnetic bearing are several. A perfect levitation is characterized by maintaining the operating point condition that is characterized by the center of stator coincident with the geometric center of shaft. The first controller implemented for this purpose is PID controller that is characterized by an algorithm that leads the amplifier to produce control current until the operating point condition is not reached, this is obtained by an integration operator. The effect of an integrator is essential but not necessary for a centered levitation for example in the robust control characterized by a dynamic model depended on plant of system so that it depends o…
Linear parameter‐varying modelling and control of an offshore wind turbine with constrained information
2014
This study deals with linear parameter-varying modelling and output-feedback H ∞ control design for an offshore wind turbine. The controller is designed with consideration that not all the information in the feedback loop will be used. This constraint is incorporated into the design procedure. Constrained information means that a special zero-non-zero pattern is forced upon the gain matrix. The constrained controller is obtained based on parameter-dependent Lyapunov functions and formulated in terms of linear-matrix inequalities. Since the functions are dependent on the wind speed and accurate wind speed measurements are rarely available in practice, an extended Kalman filter is used to est…
Nonlinear droop control for minimum power losses operation in islanded microgrids
2017
In this work, a modified primary regulation technique is proposed to control one of the inverter interfaced units feeding an islanded microgrid. The proposed approach employs an off-line minimum losses Optimal Power Flow, OPF, to extract a lookup table for the composition of the droop curve. Simulations prove that generators reach an operating point that corresponds to a minimum loss operation for the relevant power flow distribution. Since OPF has been implemented with frequency and voltage dependent models, the results of the modified droop are stable and also energy efficient. Further studies will address further analysis on systems showing different R/X ratio and modeling of more genera…
Design and control of a novel multi-source renewable energy system
2014
In this paper, a novel multi-input, single-inductor architecture is proposed. An innovative hysteretic control strategy of both the output voltage and the sources operating point control is designed and tested. Benefits brought by the proposed architecture over existing solutions are widely investigated. As an example, the design of a 48 V dual input system which is fed by photovoltaic and thermo-electric generators is proposed. Design guidelines are given and simulation results are presented to test the efficiency of the proposed architecture.
Driven Primary Regulation for Minimum Power Losses Operation in Islanded Microgrids
2018
The paper proposes an improved primary regulation method for inverter-interfaced generating units in islanded microgrids. The considered approach employs an off-line minimum losses optimal power flow (OPF) to devise the primary frequency regulation curve’s set-points while satisfying the power balance, frequency and current constraints. In this way, generators will reach an optimized operating point corresponding to a given and unique power flow distribution presenting the minimum power losses. The proposed approach can be particularly interesting for diesel-based islanded microgrids that face, constantly, the issue of reducing their dependency from fossil fuels and of enhancing their gener…
Voltage collapse proximity indicators for radial distribution networks
2007
Based on the single-line equivalent system of a radial distribution network, two simple methods to evaluate two efficient voltage collapse proximity indicators are presented and discussed. The two methods differ on the determination of the parameters which define the equivalent system from which the indicators are derived. Both methods can be conveniently used jointly for on-line applications to assess the state of a distribution system from the viewpoint of voltage stability; the first to monitoring the stability margin of the whole system loading, the second to sharpen the stability analysis at the critical node when the system operating point is in the vicinity of the loadability limit. …