Search results for "Ophthalmology"
showing 10 items of 1738 documents
Tierexperimentelle untersuchungen zur rolle von entzündungsmediatoren bei der hornhautneovaskularisation
1984
Experimental investigations concerning the role of inflammatory compounds in corneal neovascularization.Natural and synthetic inflammatory compounds were implanted in the corneas of rabbits to clarify the question whether corneal neovascularization is induced by stromal edema alone, or by neovascular mediators. It could be demonstrated that prostaglandin E1 and E2 have an angiogenetic capacity, whereas their precursor (arachidonic acid) as well as PGA1, A2, B2, I2 and Thromboxan A2 were inactive in this regard.Histology showed that corneal neovascularization is always accompanied by the invasion of polymorphonuclear leukocytes. Corneal edema in the beginning of vascularization can be explai…
Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro
2007
Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…
2015
The combination of local orientation collinearity and spatial frequency contrast in contour integration was studied in two experiments using a 2AFC contour detection and discrimination task. Target contours were defined by local orientation collinearity, spatial frequency contrast between contour and background elements, or both cues. Experiments differed in the source of spatial frequency contrast by manipulating the spatial frequency of either contour or background elements. Cue summation gains, defined as the performance benefit of double cue conditions over single cue conditions, were evaluated and tested against the predictions derived from probability summation and linear summation. S…
Simple Configuration Effects on Eye Movements in Horizontal Scanning Tasks
2015
When reading text, observers alternate periods of stable gaze (fixations) and shifts of gaze (saccades). An important debate in the literature concerns the processes that drive the control of these eye movements. Past studies using strings of letters rather than meaningful text ('z-reading') suggest that eye movement control during reading is, to a large extent, controlled by low-level image properties. These studies, however, have failed to take into account perceptual grouping processes that could drive these low-level effects. We here study the role of various grouping factors in horizontal scanning eye movements, and compare these to reading meaningful text. The results show that sequen…
VisuMax®femtosecond laser for corneal refractive surgery
2008
Femtosecond lasers are increasingly present in ophthalmologic surgical theaters for a variety of reasons. These include faster and better visual outcomes, increased accuracy and predictability for corneal flap thickness in laser in situ keratomileusis procedures. Recent applications of modern femtosecond lasers have broadened the range of uses: keratoplasty, intrastromal segment insertion and even glaucoma and presbyopia surgery. This device profile provides an overview of the advantages of femtosecond lasers in ophthalmic surgery, paying special attention to the new VisuMax® femtosecond laser from Zeiss/Meditec.
Estimation of the mechanical properties of the eye through the study of its vibrational modes.
2017
Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral a…
100 Years of Benham's Top in Colour Science
1995
For 100 years Benham's top has been a popular device demonstrating pattern-induced flicker colours (PIFCs). Results of early and recent investigations on PIFCs are reported and show that the phenomenon originates in phase-sensitive lateral interactions of modulated neural activity in the retina followed by additional spatial interactions in the visual cortex behind the locus of binocular fusion. Colour matches with normal colour stimuli indicate that S/(M + L) opponent neurons are involved. Dichromats do not find matching stimuli for all PIFCs. PIFCs may become useful in medical diagnosis. The phenomenon is interpreted as a side effect of a neural mechanism providing colour constancy under…
Spatio-temporal Contrast Sensitivity in the Cardinal Directions of the Colour Space. A Review
2010
AbstractWe review the psychophysics of the spatio-temporal contrast sensitivity in the cardinal directions of the colour space and their correlation with those neural characteristics of the visual system that limit the ability to perform contrast detection or pattern-resolution tasks. We focus our attention particularly on the influence of luminance level, spatial extent and spatial location of the stimuli - factors that determine the characteristics of the physiological mechanisms underlying detection. Optical factors do obviously play a role, but we will refer to them only briefly. Contrast sensitivity measurements are often used in clinical practice as a method to detect, at their early …
Multifokale Intraokularlinsen
2001
Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of tha…
Penetration of 2% cyclosporin eyedrops into human aqueous humour.
1989
The penetration into the eye and the systemic absorption of 2% cyclosporin eye drops were determined by polarisation immunofluorescent assay of cyclosporin in the aqueous humour and plasma of 30 patients at the time of cataract surgery. The results were then compared with the corresponding results after oral administration at a dosage of 5 mg/kg/day to three further patients. The maximum intraocular concentration (24 (SD 9) mg/l) was achieved four hours after topical administration. This level was slightly less than that found in aqueous humour (28 (SD 10) mg/l) 12 hours after systemic administration of the drug at a dosage of 5 mg/kg/day. Both these levels are below the minimum therapeutic…