Search results for "Ophthalmology"

showing 10 items of 1738 documents

Anterior chamber depth measurement in teenagers. Comparison of two techniques

2013

Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante TM OCT, Carl Zeiss Meditec) and to evaluate the degree of agreement between ACD measurements carried out by both instruments. Methods: In this prospective study 68 eyes of 34 emmetropic Caucasic patients (18 girls and 16 boys) were analysed. ACD was measured from the anterior corneal surface to anterior surface of the crystalline lens. For each age the ACD size was calculated and the difference between IOLMaster and Visante-OCT measurements was analy…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensAnterior surfaceTeenagerslcsh:OphthalmologyOptical coherence tomographyOphthalmologymedicinelcsh:QC350-467Cámara anteriorCorneal surfaceAdolescentesAnterior chamberEmmetropic Caucasic patientsmedicine.diagnostic_testbusiness.industryPacientes caucásicos emetrópicoseye diseasesPruebas diagnósticas/investigaciónlcsh:RE1-994Partial coherence interferometryMeasured depthOptometryOriginal Articlesense organsDiagnostic tests/investigationbusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

New Forceps and Spatula for Easy Retropupillary Implantation of Iris Claw Lenses in Aphakia: Experience in 4 Years of Use

2008

PURPOSE. Retropupillary implantation of an iris claw lens offers a rapid and atraumatic approach for rehabilitation of aphakic eyes. The difficulty in the implantation process arises because of the possibility of losing the intraocular lens (IOL) into the vitreous cavity and the need to change the hand holding the forceps during the enclavation. M ETHODS. The new forceps design radically changes the method of grasping an IOL. It contains an extendable supporting plate with a hook-like end. The instrument achieves a horizontal three-point fixation at the edge of the implant in the 6 and 12 o’clock position in order to prevent slippage into the vitreous cavity during the inclination. The supp…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentForcepsIrisIntraocular lensAphakia PostcataractAphakiaVitreous cavitylaw.inventionFixation (surgical)Lens Implantation IntraocularlawOphthalmologymedicineHumansIris clawLenses IntraocularPhacoemulsificationbusiness.industryEquipment DesignGeneral Medicinemedicine.diseaseCentrationeye diseasesSurgeryLens (optics)Ophthalmologysense organsbusinessEuropean Journal of Ophthalmology
researchProduct

Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?

2014

The visual outcome obtained after cataract removal may progressively decline because of posterior capsular opacification (PCO). This condition can be treated by creating an opening in the posterior lens capsule by Nd:YAG laser capsulotomy. PCO optical imperfections cause several light reflection, refraction, and diffraction phenomena, which may interfere with the functional and structural tests performed in different ocular locations for the diagnosis and follow-up of ocular disease, like macular and optic nerve diseases. Some parameters measured by visual field examinations, scanning laser polarimetry, and optical coherence tomography (OCT) have changed after PCO removal. Imaging quality a…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentOptic DiskScanning laser polarimetryGlaucomalcsh:MedicineReview ArticleDiagnostic Techniques OphthalmologicalRetinaGeneral Biochemistry Genetics and Molecular BiologyOptical coherence tomographyOphthalmologymedicineHumansPosterior CapsulotomyRetinaGeneral Immunology and Microbiologymedicine.diagnostic_testPosterior Capsulotomybusiness.industrylcsh:RGeneral MedicineCapsule Opacificationmedicine.diseaseeye diseasesVisual fieldmedicine.anatomical_structureCapsulotomysense organsbusinessOptic discBioMed Research International
researchProduct

Visual Performance after AcrySof ReSTOR Aspheric Intraocular Lens Implantation

2008

Purpose: To evaluate distance, intermediate and near visual performance in patients who had undergone implantation of the multifocal aspheric AcrySof ReSTOR intraocular lens (IOL). Methods: Binocular best distance corrected visual acuity (BCVA) at high and low contrast [4 m], best distance corrected near visual acuity (BCNVA) [40 cm], intermediate visual acuity [80 and 60 cm], and distance contrast sensitivity (CS) under photopic [85 cd/m2] and mesopic [3 cd/m2] conditions, were measured in 36 eyes that underwent implantation of the AcrySof ReSTOR Aspheric IOL (SN6AD3). Results: At the 3-month postoperative visit, binocular BCVA was -0.058±0.091, 0.200±0.079, and 0.258±0.071 logMAR, for 100…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentdiffractionLIO multifocalIntraocular lenslcsh:OphthalmologyOphthalmologymedicinemultifocal IOLvisual functionlcsh:QC350-467In patientasfericidaddifracciónbusiness.industryfunción visualeye diseasesasphericityVisual functionlcsh:RE1-994OptometryOriginal Articlesense organsbusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Retina Summit Karlsruhe 2009

2009

During the this year´s Retina Summit Karlsruhe, an international expert faculty of 20 highly renowned retina specialists and more than 300 participants found their way to Karlsruhe to share their knowledge of the latest trends in surgical technology and pharmacology. After an angiography course on Friday, the 1-day symposium of almost 40 short lectures covered recent developments in age-related macular degeneration and diabetic macular edema, and the implications and challenges associated with microincision vitrectomy surgery, new devices and advances in imaging technologies.

medicine.medical_specialtygenetic structuresmedicine.medical_treatmenteducationDiabetic macular edemaBiomedical EngineeringVitrectomySurgical technologyOphthalmologymedicineRetinageographySummitgeography.geographical_feature_categorymedicine.diagnostic_testbusiness.industryMacular degenerationmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureAngiographyOptometrysense organsbusinessOptometryExpert Review of Ophthalmology
researchProduct

Analysis of the Peripapillary and Macular Regions Using OCT Angiography in Patients with Schizophrenia and Bipolar Disorder

2021

Purpose: To measure RNFL and vasculature around the optic disc and in the macula in patients with schizophrenia (SZ) and bipolar disorder (BD) using optical coherence tomography angiography (OCTA). Methods: 24 eyes of patients with SZ and 16 eyes of patients with BD as well as 30 eyes of healthy subjects were examined with OCTA. The radiant peripapillary capillary (RPC) density and RNFL thickness were measured in the peripapillary area. Moreover, macular thickness and vessel density were measured in both superficial and deep layers. Results: Significantly decreased values of vessel density in the macular deep vascular complex were found in the eyes of patients with SZ, compared to BD and th…

medicine.medical_specialtygenetic structuresmicrovascular dysfunctionArticlechemistry.chemical_compoundOct angiographyOphthalmologymedicineIn patientBipolar disorderbipolar disorderbusiness.industryHealthy subjectsRRetinalGeneral MedicineOptical coherence tomography angiographymedicine.diseaseeye diseasesschizophreniamedicine.anatomical_structurechemistrySchizophreniaMedicinesense organsbusinessOCTAOptic discJournal of Clinical Medicine
researchProduct

Binocular Vision in Patients with Multiple Sclerosis.

2021

Amparo Gil-Casas,1,2 David P Piñero-Llorens,2 Ainhoa Molina-Martin2 1Clínica Optométrica, Fundació Lluís Alcanyís, University of Valencia, Valencia, Spain; 2Optics and Visual Perception Group (GOPV), Department of Optics, Pharmacology, and Anatomy, University of Alicante, Alicante, SpainCorrespondence: Ainhoa Molina-MartinDepartment of Optics, Pharmacology, and Anatomy, University of Alicante, Carretera San Vicente del Raspeig, San Vicente del Raspeig, 03690, Alicante, SpainTel +34 965 903-400Email ainhoa.molina@ua.esPurpose: Oculomotor disorders have been reported in multiple sclerosis (MS) in up to 80% of cases. There have …

medicine.medical_specialtyheterophoriagenetic structuresStereoscopymultiple sclerosislaw.inventionMultiple sclerosislawOphthalmologymedicineOptic neuritisClinical OptometryStereopsisfusional vergencesÓpticaOriginal Researchbinocular visionnear point of convergenceMonocularbusiness.industryMultiple sclerosisFusional vergencemedicine.diseasestereopsisSensory Systemseye diseasesOphthalmologyStereopsisHeterophoriaHeterophoriaFusional vergencesNear point of convergenceBinocular visionbusinessBinocular visionClinical optometry
researchProduct

2017

The mere presence of a depiction of eyes can elicit a sense of being watched in the perceiver. To this date, the factors affecting the intensity of this sense of being watched, however, have not been investigated. In the present experiment, we tested the impact of two potentially relevant variables: arousal (manipulated using specific musical pieces) and duration of the perceptual episode (manipulated using presentation times of 200 ms and 10 s, respectively). We asked participants to report how intensely they felt being watched while we exposed them to various observation cues ranging from human eyes to surveillance cameras. We found that, on average, reported intensities were higher if pa…

medicine.medical_specialtymedia_common.quotation_subject05 social sciences050109 social psychologyExperimental and Cognitive PsychologyAudiology050105 experimental psychologySensory SystemsArousalOphthalmologyArtificial IntelligenceDuration (music)Perceptionmedicine0501 psychology and cognitive sciencesPsychologyPractical implicationsmedia_commoni-Perception
researchProduct

Effect of Different Display Types on Vection and Its Interaction With Motion Direction and Field Dependence

2017

Illusory self-motion (vection) can be generated by visual stimulation. The purpose of the present study was to compare behavioral vection measures including intensity ratings, duration, and onset time across different visual display types. Participants were exposed to a pattern of alternating black-and-white horizontal or vertical bars that moved either in vertical or horizontal direction, respectively. Stimuli were presented on four types of displays in randomized order: (a) large field of view dome projection, (b) combination of three computer screens, (c) single computer screen, (d) large field of view flat projection screen. A Computer Rod and Frame Test was used to measure field depen…

medicine.medical_specialtymedia_common.quotation_subjectlcsh:BF1-990Field dependenceExperimental and Cognitive PsychologyperceptionAudiologyArticle050105 experimental psychology03 medical and health sciences0302 clinical medicineArtificial IntelligencePerceptionmedicineMotion direction0501 psychology and cognitive sciencescircular vectionmedia_commonfield dependence or field independence05 social scienceshumanitiesSensory Systemscognitive styleIntensity (physics)Ophthalmologylcsh:PsychologyDuration (music)optic flowillusory self-motionfield of viewPsychologyvisual stimulation030217 neurology & neurosurgeryi-Perception
researchProduct

Polypoidal Choroidal Vasculopathy

2009

Polypoidal choroidal vasculopathy does not constutute part of the classical definition of AMD, but these two en tities have a number of features in common.

medicine.medical_specialtymedicine.anatomical_structurebusiness.industryOphthalmologymedicineOuter nuclear layerbusiness
researchProduct