Search results for "Ophthalmology"
showing 10 items of 1738 documents
Reproducibility of digital image analysis for measuring corneal haze after myopic photorefractive keratectomy.
1997
Purpose To evaluate the usefulness of digital image analysis for quantifying corneal haze by determining the reproducibility of its measurements at the corneal plane. Methods In a prospective study, 20 randomly selected eyes that had undergone myopic photorefractive keratectomy were photographed focusing the slit beam on their anterior corneal surface. Each photograph was examined using computer image analysis techniques that detect the edge of the reticular pattern of the image. Quantification of the difference between two areas, treated and adjacent untreated cornea, each containing 3,750 pixels with a resolution of 256 gray levels, was performed. Intra-analyzer variation was determined b…
Direct Objective Quantification of Corneal Haze after Excimer Laser Photorefractive Keratectomy for High Myopia
1996
Purpose: The purpose of the study is to measure regional distribution differences in corneal haze after excimer laser photorefractive keratectomy for high myopia. Methods: The authors developed computerized gradient edge detectors with which were analyzed digitized anterior slit-lamp photographs of 40 eyes, an average of 21.0 plus or minus 14.5 weeks after photorefractive keratectomy for high myopia (−6 to −22 diopters). A treated area and an adjacent untreated area on the anterior corneal surface, each containing six regions, were quantified, and the difference was correlated with various parameters. Results: Mean differences between scarred and clear areas for haze grade 0.5, 1.0, 2.0, 3.…
Phakic intraocular lenses to correct high myopia
2003
Abstract Purpose: To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. Setting: La Fe University Hospital, Department of Ophthalmology, and the Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods: In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was −15.39 diopters (D) ± 2.83 (SD), −16.00 ± 5.05 D, and −16.17 ± 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The …
Mesopic contrast sensitivity function after excimer laser photorefractive keratectomy.
2002
ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who had undergone uncomplicated excimer laser photorefractive keratectomy (PRK) for myopia. METHODS: Monocular contrast sensitivity function was measured with the Stereo Optical ?A.C.T. chart in 26 patients who had received PRK using the Nidek EC-5000 excimer laser system. Mean preoperative refractive error was -6.23 ? 1.69 D (range, -4.00 to -8.25 D); postoperatively, mean refractive error was -0.36 ? 0.58 D (range, -0.75 to +0.50 D). Contrast sensitivity function was measured 6 months after surgery using four different chart luminances: 85, 5.0, 2.5, and 0.1 cd/m2, the first being a photopic level and …
Mesopic Contrast Sensitivity Function After Laser in situ Keratomileusis
2003
ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who have undergone uncomplicated bilateral laser in situ keratomileusis (LASIK) for myopia. METHODS: Best-corrected monocular contrast sensitivity was measured with the Stereo Optical F.A.C.T. chart at 1.5, 3, 6, 12, and 18 c/deg in 20 patients (20 left eyes) before and after bilateral LASIK (with the Nidek EC-5000 excimer laser and the Automated Corneal Shaper). Mean preoperative refractive error was -6.40 ± 1.28 D (range -4.00 to -8.00 D) and postoperative mean refractive error was -0.41 ± 0.45 D (range -0.75 to +0.50 D). Contrast sensitivity function was measured before and 6 months after surgery usin…
Iris Claw Phakic Intraocular Lens for High Myopia
1997
ABSTRACT BACKGROUND: The implantation of a WorstFechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stähle refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow -up of 3 years. METHODS: We studied 94 eyes of 62 patients with myopia 5= -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS: Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years af…
Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses
1995
Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.
Excimer laser photorefractive keratectomy for high myopia
1995
Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…
Prevalence of corneal astigmatism before cataract surgery.
2008
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
Long-term Results After Transconjunctival Resuturing of the Scleral Flap in Hypotony Following Trabeculectomy
2013
Purpose To present the 4-year follow-up results in the surgical treatment of hypotony following trabeculectomy with mitomycin C in glaucoma patients with additional flap sutures. Design Retrospective interventional case series. Methods Since 2006, 53 patients with hypotony maculopathy attributable to overfiltration following glaucoma surgery (trabeculectomy with mitomycin C) were included in this institutional study. We were able to follow up intraocular pressure (IOP) and distance-corrected visual acuity in 33 (62%) over 4 years, whereas all were followed over 2 years. To elevate IOP, we placed tangential transconjunctival sutures through the scleral flap and connected them to the adjacent…