Search results for "Optical Coherence Tomography"
showing 10 items of 148 documents
Optical coherence tomography of chorioretinal and choroidal folds
2007
. Purpose: To report the optical coherence tomography (OCT) findings in cases of chorioretinal and choroidal folds. Methods: Eight subjects with folds of the fundus of the eye were examined with fundus photography, fluorescein angiography, B-scan ultrasonography and Stratus OCT. Results: Two types patterns were found on OCT. Five cases showed undulating retinal as well as retinal pigment epithelial lines of normal thickness; these were defined as chorioretinal folds. The posterior vitreous surface often adhered to the crests of the folds only. Three cases exhibited a wavy appearance of the retinal pigment epithelium and a flat retinal surface; these were classified as choroidal folds. Co…
Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT
2021
Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…
Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study
2018
Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…
Serum neurofilament levels reflect outer retinal layer changes in multiple sclerosis
2021
Background: Serum neurofilament light chain (sNfL) and distinct intra-retinal layers are both promising biomarkers of neuro-axonal injury in multiple sclerosis (MS). We aimed to unravel the association of both markers in early MS, having identified that neurofilament has a distinct immunohistochemical expression pattern among intra-retinal layers. Methods: Three-dimensional (3D) spectral domain macular optical coherence tomography scans and sNfL levels were investigated in 156 early MS patients (female/male: 109/47, mean age: 33.3 ± 9.5 years, mean disease duration: 2.0 ± 3.3 years). Out of the whole cohort, 110 patients had no history of optic neuritis (NHON) and 46 patients had a previous…
Ocular biometry with swept-source optical coherence tomography
2020
This study aimed to summarize the outcomes reported when swept-source optical coherence tomography (SS-OCT) is used for ocular biometry. A literature search was performed to identify publications reporting clinical outcomes of patients measured with commercial SS-OCT. Twenty-nine studies were included in this review. A comprehensive analysis of the available data was performed, focusing on parameters used for intraocular lens (IOL) power calculation in cataract surgery, including keratometry, central corneal thickness, white-to-white distance, anterior chamber depth, lens thickness, axial length, IOL power, and pupil diameter. Different metrics for repeatability, reproducibility, and agreem…
Site-Coded Oral Squamous Cell Carcinoma Evaluation by Optical Coherence Tomography (OCT): A Descriptive Pilot Study
2022
Optical Coherence Tomography (OCT) is an emerging non-invasive method for oral diagnostics, proving to be a practicable device for epithelial and subepithelial evaluation. The potential validity of OCT in oral cancer assessment has been explored but, to date, there are very few investigations conducted with a systematic comparison between clinical/histological and OCT parameters, especially in strict reference to the anatomical site-codification of the oral mucosa. In this regard, our study performed a two-steps evaluation (in vivo OCT and histological investigations) of suspected OSCCs, progressively recruited, using as references the OCT images of the same site-coded healthy mucosa, to pr…
Response by Meneveau and Ecarnot to Letter Regarding Article, “Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention…
2017
We read with interest the letters by Vallurupalli and Uretsky and also Dr Nadir relating to the results of the DOCTORS study (Does Optical Coherence Tomography Optimize Results of Stenting).1 We thank the authors for their insightful remarks. Vallurupalli and Uretsky raise an interesting point when they underline that a prolonged inflation time is superior to a rapid inflation/deflation technique in terms of both stent expansion and apposition. We acknowledge that we did not take stent inflation time into account in the case report form of the DOCTORS study. The arguments put forward by Vallurupalli and Uretsky suggest that this variable should be systematically recorded and reported. Howev…
In Vitro Measurement of Strain Localization Preceding Dissection of the Aortic Wall Subjected to Radial Tension
2020
AbstractBackgroundAortic dissection (AD) is a common pathology and challenging clinical problem. A better understanding of the biomechanical effects preceding its initiation is essential for predicting adverse events on a patient-specific basis. Moreover, the predictability of patient-specific biomechanics-based computational models is hampered by uncertainty about boundary conditions and material properties.ObjectivePredisposition of thoracic aortic aneurysms (TAA) to ADs can be related to the degradation of biomechanically important constituents in the aortic wall of TAAs. The goal of the present study is to develop a new methodology to measure strain fields in aortic tissues subjected to…
The Usefulness of Optical Coherence Tomography in Disease Progression Monitoring in Younger Patients with Relapsing-Remitting Multiple Sclerosis: A S…
2022
The purpose of the study was to assess the usefulness of optical coherence tomography (OCT) in the detection of the neurodegenerative process in younger patients with multiple sclerosis (MS). The study group consisted of 61 patients with a relapsing remitting course of MS (mean age 36.4 ± 6.7 years) divided into two groups: short (≤5 years) and long (>10 years) disease duration. OCT, P300 evoked potential, Montreal Cognitive Assessment, and performance subtests (Picture Completion and Digit Symbol) of the Wechsler Adult Intelligence Scale were performed in all patients. Mean values of most parameters assessed in OCT (pRNFL Total, pRNFL Inferior, pRNFL Superior, pRNFL Temporalis, mRNFL, G…
Yellow (577 nm) micropulse laser versus half-dose verteporfin photodynamic therapy in eyes with chronic central serous chorioretinopathy: results of …
2018
PurposeTo compare the functional and anatomical outcomes of eyes with chronic central serous chorioretinopathy treated with yellow micropulse (MP) laser versus half-dose verteporfin photodynamic therapy (PDT).MethodsThis is a multicentre, retrospective comparative study of 92 eyes treated with yellow MP laser (duty cycle of 5%, zero spacing between spots, spot size varied from 100 to 200 µm, power varied from 320 to 660 mW, and the pulse burst duration was 200 ms) and 67 eyes treated with PDT (half-dose verteporfin (3 mg/m2) infused over 10 min), followed by laser activation for 83 s. Spot sizes varied from 400 to 2000 µm.ResultsIn the MP group, at 12 months of follow-up, the mean best corr…