Search results for "Optical transfer function"
showing 10 items of 53 documents
Three-dimensional point spread function of multilayered flat lenses and its application to extreme subwavelength resolution
2011
The three-dimensional (3D) point spread function (PSF) of multilayered flat lenses was proposed in order to characterize the diffractive behavior of these subwavelength image formers. We computed the polarization-dependent scalar 3D PSF for a wide range of slab widths and for different dissipative metamaterials. In terms similar to the Rayleigh criterion we determined unambiguously the limit of resolution featuring this type of image-forming device. We investigated the significant reduction of the limit of resolution by increasing the number of layers, which may drop nearly 1 order of magnitude. However, this super-resolving effect is obtained in detriment of reducing the depth of field. Li…
Influencia del modelo de ojo teórico en la evaluación numérica de lentes intraoculares fractales
2020
In this work we present the numerical evaluation of a new design of fractal intraocular lens studied through a ray-tracing program. To determine the monochromatic and polychromatic performance of these lenses in different theoretical model eyes the Modulation Transfer Function (MTF) and the area above the MTF (AMTF) have been used. These merit functions show the same behavior for different values of asphericity (Q), independently from the theoretical model eye, even though there are differences due to the Spherical Aberration (SA) considered in each model.
Nonsymmetric Fourier transforming with an anamorphic system
1984
The idea of obtaining a nonsymmetric Fourier transform with crossed cylindrical lenses of different focal lengths is presented. The anamorphic rotation-variant system produces a scaled Fourier transform F(u,mv) of an object f(x,y), where m is a scaling constant. The system performs controlled angular magnification of an object spectrum. It is shown that the super resolution in one direction is gained by reducing the number of degrees of freedom of the optical message in the other. Experimental results are shown where the scaling constant m of up to 10 has been obtained.
Transversal superresolution with noncontact axial movement of periodic structures
2007
We present an innovative approach that allows superresolved images to be obtained by axial moving of two gratings and time integrating in the detector plane. The two gratings do not have to be in contact with either the object or the detector, and both are positioned between the object and the image planes. One of the main applications for the proposed approach in contrast to previously discussed time multiplexing superresolving methods is that it may fit well to superresolved imaging of remote objects, since both gratings are not in contact with either the object or the detector planes.
Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.
2014
Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…
Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.
2013
Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…
Imaging Performance of a Diffractive Corneal Inlay for Presbyopia in a Model Eye
2019
[EN] In this work we evaluated the imaging properties of the Diffractive Corneal Inlay (DCI), a novel type of corneal implant working by diffraction that we proposed for the treatment of presbyopia. ZEMAX OpticStudio software was employed for the numerical assessment, with simulations performed in a human-based eye model. In the ray tracing analysis, we used the Modulation Transfer Function (MTF), the Area under the MTF (AMTF), and the Point Spread Function (PSF). The theoretical performance of the DCI under different situations was evaluated in comparison with a commercially available pinhole based corneal inlay. Finally, real images were obtained experimentally in vitro in a model eye wit…
Multiframe image restoration in the presence of noisy blur kernel
2009
We wish to recover an original image u from several blurry-noisy versions f k , called frames. We assume a more severe degradation model, in which the image u has been blurred by a noisy (stochastic) point spread function. We consider the problem of restoring the degraded image in a variational framework. Since the recovery of u from one single frame f is a highly ill-posed problem, we formulate two minimization problems based on the multiframe approach proposed for image super-resolution by Marquina-Osher [13]. Several experimental results for image restoration are shown, illustrating that the proposed models give visually satisfactory results.
Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator
2012
A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.
Optical Characterization Method for Tilted or Decentered Intraocular Lenses
2016
Purpose To test and validate a method for measuring the optical quality and optical power of monofocal intraocular lenses (IOLs) in the presence of a tilt or a decentration as well as its optical power. Methods The experimental system consists of an artificial eye (wet-cell) and a commercial aberrometer with a Shack-Hartmann sensor. Optical image quality parameters such as point spread function (PSF), modulation transfer function (MTF), and the simulations of the retinal image of an extended object are computed from the in vitro wavefront data of an IOL. Repeatability and reproducibility of the system are tested. Mathematical and ray-tracing simulations are used to ascertain the precision a…