Search results for "Optical"
showing 10 items of 7671 documents
Illusory contours from pictorially three-dimensional inducing elements: counterevidence for Parks and Rock's example.
1993
In 1990 Parks and Rock claimed that, in pictorially three-dimensional (3-D) inducing patterns, an illusory figure does not emerge if a clear occlusion event is not present. A new pictorially 3-D pattern is presented which contradicts this claim. Two experiments were carried out. The first was aimed at ascertaining the presence of an illusory figure in the new 3-D pattern; the second was aimed at offering evidence that in Parks and Rock's pattern the disappearance of the illusory figure could be due to local interferences caused by the line elements in contact with the inducing borders. The results tend to contradict Parks and Rock's conclusions.
Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Effect of age in the ciliary muscle during accommodation: Sectorial analysis
2017
Abstract Purpose To compare changes in the ciliary muscle area at different sectors between pre-presbyopic and presbyopic eyes during accommodation by means of an anterior segment optical coherence tomographer (OCT). Methods The anterior ciliary muscle area was measured in 20 healthy and phakic pre-presbyopic eyes, whose mean age was 23.3 ± 4.4 years, and in 20 healthy and phakic presbyopic eyes, whose mean age was 46.5 ± 5.2 years. The relative change in the cross-sectional area of the ciliary muscle was measured at the nasal, inferior, and temporal sectors between 0 and −3 D of vergence, in −1 D step. A linear model was used to assess the correlation of each eye parameter with the accommo…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…
Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability
2001
Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Illusory contours and specific regions of human extrastriate cortex: evidence from rTMS.
2003
Functional magnetic resonance imaging studies showed that perception of illusory contours is associated with extrastriate cortex activation prevailing on the right side. 1 Hz repetitive transcranial magnetic stimulation (rTMS) is able to induce lasting inhibition of cortical activity. The objective of the study was to investigate the role of extrastriate cortex in illusory contour perception inducing 1 Hz rTMS interference in healthy subjects. Eight healthy subjects underwent 1 Hz rTMS (600 pulses) through a figure-of-eight coil over right and left occipital cortex (O1 and O2 of 10/20 EEG system); sham magnetic stimulation on the same sites and right motor cortex rTMS (in three subjects) we…
Marine sponge collagen: isolation, characterization and effects on the skin parameters surface-pH, moisture and sebum
2002
A previously described isolation procedure for collagen of the marine sponge Chondrosia reniformis Nardo was modified for scaling-up reasons yielding 30% of collagen (freeze-dried collagen in relation to freeze-dried sponge). Light microscope observations showed fibrous structures. Transmission electron microscopy studies proved the collagenous nature of this material: high magnifications showed the typical periodic banding-pattern of collagen fibres. However, the results of the amino acid analysis differed from most publications, presumably due to impurities that still were present. In agreement with earlier studies, sponge collagen was insoluble in dilute acid mediums and all solvents inv…
Comparison of service tactic formation on players’ movements and point outcome between national and beginner level padel
2021
The aim of this study was to analyze the influence of service tactic formation on players’ movements and point outcome at two different performance levels. The sample contained 2,148 points corresponding to 18 matches from two male padel indoor tournaments. Players were classified according to their game level: high-level (N = 36; age = 33.3 ± 6.9 years) and beginner (N = 36; age = 35.4 ± 6.8 years). Variables pertaining to service tactic formation (conventional or Australian), point outcome and movement patterns were analysed from the matches through systematic observation. The results showed how high-level players used a significantly higher percentage of the Australian formation than beg…
Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk
2017
Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…