Search results for "Optical"
showing 10 items of 7671 documents
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT.
2015
Background: The exact pathogenesis of open angle glaucoma and ocular hypertension remains unclear. Hemodynamic influences are discussed as potential risk factors and the choroid may play an important role in the pathogenesis of open angle glaucoma or ocular hypertension. The current study investigates peripapillary choroidal thickness and choroidal area in patients with open angle glaucoma, subjects with ocular hypertension and healthy subjects using spectral-domain OCT. It furthermore assesses the association between peripapillary choroidal thickness and age, central corneal thickness, refractive error and intraocular pressure. Patients and Methods: Prospectively recorded data of 213 eyes …
Presence and Emotions in Virtual Environments: The Influence of Stereoscopy
2008
ABSTRACT This study investigates how stereoscopy (the illusion of depth and 3D imaging) affects the sense of presence and the intensity of the positive mood that users feel in virtual environments (VEs). A between-group design was used, and 40 volunteers were randomly assigned to one of two experimental conditions (stereoscopy vs. no stereoscopy) and to one of two emotional VEs (relaxation or joy). The participants' emotions were assessed before and after the VR experience. Presence was measured with two postexperiment questionnaires (ITC-SOPI and SUS). Results show that there were no differences between stereoscopic and monoscopic presentations in VEs (neither subjective sense of presence …
Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool
2021
Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography
2019
ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …
OCT is not useful for detection of minimal diabetic retinopathy in type 1 diabetes.
2009
Optical coherence tomography (OCT) has been proven useful in measuring retinal thickness (RT) in patients with diabetes, although with discordant results in different studies. We examined RT in patients with type 1 diabetes (T1D) with or without minimal diabetic retinopathy (MDR) to test whether OCT is able to identify early retinal changes and potential correlations with metabolic parameters. RT of 102 patients with T1D (53 females, 49 males, aged 27.03 +/- 7.4 years) and of 42 healthy controls was examined, with analysis of nine different sectors (fovea, four pericentral and four peripheral sectors). According to the results of basal fundus photography, patients were divided into two grou…