Search results for "Orthodontics."

showing 10 items of 920 documents

Correlation between alteration of enamel roughness and tooth color

2018

Background To establish the correlation between enamel roughness and color change of tooth. Material and Methods Enamel/dentin blocks (5 x 5 x 3.2 mm) were serially ground with the following abrasive paper: 1200-grit, 800-grit, and 600-grit SiC papers. In the paired model, the analyses of color (L*, a*, b*, ΔE) and roughness (Ra) were performed among the sandpaper exposure. The data were subjected to ANOVA using models for repeated measures followed by the Tukey test. The Pearson correlation test was used to determine whether there was a relationship between Ra values and color results (α = 0.05). Results The L* values decreased in accordance with the increase of Ra, with statistical differ…

OrthodonticsLightnessMaterials scienceEnamel paintResearchAbrasiveEsthetic Dentistry030206 dentistrySurface finish:CIENCIAS MÉDICAS [UNESCO]Tooth discolorationstomatognathic diseases03 medical and health sciences0302 clinical medicinemedicine.anatomical_structurestomatognathic systemvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumTukey's range testDentinmedicineGeneral Dentistry030217 neurology & neurosurgerySandpaperJournal of Clinical and Experimental Dentistry
researchProduct

Effects of piezocision in orthodontic tooth movement : a systematic review of comparative studies

2019

Background The aim of this systematic review was to evaluate the effects of piezocision in accelerating orthodontic tooth movement (OTM) and its possible adverse effects. Material and methods The Databases Medline, Embase, CENTRAL and LILACS were searched until March 2019, for randomized controlled trials (RCTs) and controlled clinical trials (CCTs) that used piezocision associated with orthodontic treatment. A manual search was also performed. The search, studies selection, assessment of risk of bias and data collection were carried out by two independent reviewers. Results Eleven publications were included in this review (4 CCTs and 7 RCTs). No study presented low risk of bias. Different …

OrthodonticsLower anteriorbusiness.industryMEDLINEOrthodonticsReview030206 dentistryRoot resorptionmedicine.disease:CIENCIAS MÉDICAS [UNESCO]law.inventionClinical trial03 medical and health sciences0302 clinical medicineRandomized controlled triallawTooth movementUNESCO::CIENCIAS MÉDICASPain perceptionMedicine030212 general & internal medicinebusinessAdverse effectGeneral Dentistry
researchProduct

2021

The aim of the study was to (1) assess the within-session reliability of a unilateral isometric hex bar pull (UIHBP) maximal voluntary contraction (MVC) test and, (2) determine unilateral isometric absolute peak force (PFabs) and relative peak force (PF) values in freeski athletes. Twenty-one male and eight female academy to national team freeskiers performed the novel UIHBP MVC task on a force plate and PFabs and relative PF were assessed (1000 Hz). Within-session measures of PFabs offered high reliability on left and right limbs for males (ICC = 0.91–0.94, CV = 2.6–2.2%) and females (ICC = 0.94–0.94, CV = 1.4–1.6%), while relative PF measures showed good to high reliability in both left a…

OrthodonticsLower bodyVoluntary contractionbiologybusiness.industryAthletesStatistical differenceMedicineStrength testingIsometric exercisebusinessbiology.organism_classificationReliability (statistics)Frontiers in Sports and Active Living
researchProduct

Effectiveness and Duration of Plantar Pressure Off-loading by Two Designs of Felt Padding: A Preliminary Study.

2019

Background: The aim of this study was to observe the pressure changes in the felt padding used to off-load pressure from the first metatarsal head, the effects obtained by different designs, and the loss of effectiveness over time. Method: With a study population of 17 persons, two types of 5-mm semicompressed felt padding were tested: one was C-shaped, with an aperture cutout at the first metatarsophalangeal joint, and the other was U-shaped. Pressures on the sole of the foot were evaluated with a platform pressure measurement system at three time points: before fitting the felt padding, immediately afterward, and 3 days later. Results: In terms of decreased mean pressure on the first met…

OrthodonticsMaleMetatarsophalangeal JointAdolescentbusiness.industryFootPlantar pressureFirst metatarsalFoot OrthosesGeneral MedicineEquipment DesignWalkingMiddle AgedPaddingYoung AdultDuration (music)PressureMedicineHead (vessel)HumansFemalebusinessFoot OrthosesMetatarsal BonesJournal of the American Podiatric Medical Association
researchProduct

Footwear outsole temperature may be more related to plantar pressure during a prolonged run than foot temperature.

2021

Objective. The temperature of the sole of the foot has been suggested as an alternative to the measurement of plantar pressure during running despite the scarce evidence about their relationship. The temperature of the footwear outsole could also be representative of plantar pressure distribution due to its less multifactorial dependence. The aim of the study was to determine if plantar pressure during a prolonged run could be related to plantar temperature, either of the sole of the foot or the footwear outsole.Approach. Thirty recreational runners (15 males and 15 females) performed a 30 min running test on a treadmill. Thermographic images of the sole of the foot and the footwear outsole…

OrthodonticsMalePhysiologybusiness.industryFootPlantar pressureForefootBiomedical EngineeringBiophysicsTemperatureBiomechanical PhenomenaRunningShoesbody regionsThermographyPhysiology (medical)MedicineHumansFemaleTreadmillbusinesshuman activitiesFoot (unit)Physiological measurement
researchProduct

Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT)

2012

Aims: To evaluate the reliability and reproducibility of calculating the Bolton Index using cone-beam computed tomography (CBCT), and to compare this with measurements obtained using the 2D Digital Method. Material and Methods: Traditional study models were obtained from 50 patients, which were then digitized in order to be able to measure them using the Digital Method. Likewise, CBCTs of those same patients were undertaken using the Dental Picasso Master 3D® and the images obtained were then analysed using the InVivoDental programme. Results: By determining the regression lines for both measurement methods, as well as the difference between both of their values, the two methods are shown t…

OrthodonticsMaleReproducibilityCone beam computed tomographyMeasurement methodIndex (economics)medicine.diagnostic_testbusiness.industryDentistryComputed tomographyCone-Beam Computed TomographyOtorhinolaryngologyClinical and Experimental DentistryLinear regressionMedicineHumansSurgeryResearch-ArticleFemalebusinessGeneral DentistryReliability (statistics)MalocclusionMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Effect of cusp coverage and water storage on compressive strength of composite restorations of premolars

2018

Background The aim of this study was to assess the effect of cusp coverage and water storage on compressive strength of composite restorations. Material and Methods This in vitro experimental study was conducted on 40 extracted human maxillary premolar teeth, which were randomly divided into four groups of 10. Mesio-occluso-distal (MOD) cavities were prepared in all teeth. The thickness of composite for cusp coverage was 1.5 mm in groups 1 and 3 and 2.5 mm in groups 2 and 4. Compressive strength (CS) was measured after 24 hours in groups 1 and 2 and after six months of water storage in groups 3 and 4. Two-way ANOVA was used to statistically analyze the data. Results The mean and standard er…

OrthodonticsMaterials scienceAbsorption of waterResearchSignificant differenceComposite number02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesOperative Dentistry and Endodontics0104 chemical sciencesmedicine.anatomical_structureCompressive strengthFlexural strengthUNESCO::CIENCIAS MÉDICASPremolarmedicineCusp (anatomy)Statistical analysis0210 nano-technologyGeneral Dentistry
researchProduct

Mechanical properties of the NiTi Memoria Leaf Spring Activated Expander (NiTi MLSAE) for maxillary transverse discrepancy correction: An in-vitro st…

2020

Background To determine the mechanical properties of the NiTi Memoria® Leaf Spring Activated Expander (NiTi MLSAE) in two forms, unaltered (unbent) and altered (bent) to mimic clinical use. Material and Methods This in-vitro pilot study was conducted using eight NiTi MLSAE expanders (American Tooth Industries, Oxnard, California) representing four force magnitudes: 10mm 500g, 10mm 900g, 6mm 450g and 6mm 900g models. Two experiments were performed: the first tested the expanders in their unbent form and the second tested them after they were bent by one experienced technician. All expanders were adapted to a standard three dimensional printed maxillary study model. A Dillion Quantrol 500N (1…

OrthodonticsMaterials scienceBent molecular geometry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]Posterior crossbite01 natural sciencesLoad cellTransverse plane020303 mechanical engineering & transports0203 mechanical engineeringLeaf springNickel titaniumUNESCO::CIENCIAS MÉDICAS0103 physical sciencesIn vitro study010301 acousticsGeneral DentistryExpansiveJournal of Clinical and Experimental Dentistry
researchProduct

Sind winkelstabile Plattensysteme mit elastischen Eigenschaften für die Stabilisierung der Oberarmkopffraktur vorteilhaft? / Eine in-vitro biomechani…

2004

AbstractWinkelstabile Platten werden mit zunehmender Häufigkeit zur Stabilisierung von Oberarmkopfbrüchen verwendet. Rigide Implantate führen bei osteoporotischen Knochenverhältnissen u. U. aber häufiger zum Versagen. Um den Effekt der Implantatelastizität zu beurteilen wurden in einer in-vitro Studie die biomechanischen Eigenschaften eines rigiden und eines elastischen winkelstabilen Plattensystems vergleichend analysiert. An 8 Humeruspaaren wurde eine instabile subkapitale Fraktur simuliert. Die Proben wurden axial- und torsions-belastet. Analysiert wurden die Steifigkeit, das Setzverhalten unter Dauerlast und die Versagensbelastung.Das elastische Plattensystem kennzeichnete sich durch ei…

OrthodonticsMaterials scienceBiomedical EngineeringBiomechanicsStiffnessmedicine.anatomical_structureFracture fixationLoad to failuremedicineHumerusUnstable fractureImplantmedicine.symptomElasticity (economics)Biomedizinische Technik/Biomedical Engineering
researchProduct

Dynamische Analyse von Osteosynthesen am Olecranon: ein in-vitro Vergleich zweier Osteosynthesesysteme / Dynamic analysis of olecranon osteosyntheses…

2008

INTRODUCTION The aim of the present study was to develop a test setup with continuous angle alteration to imitate elbow joint motion for the mechanical evaluation of tension band wiring and a newly designed intramedullary nail. MATERIALS AND METHODS The servo-pneumatical test stand worked with a rotational angle-adjusted and a linear force-adjusted engine. The fracture model was dynamically tested under cyclic loading imitating elbow joint motion. In total, 14 fresh cadaver upper extremities underwent olecranon fracture by means of transverse osteotomy and were assigned to two groups: tension band wiring and intramedullary nailing. There was a continuous angle alteration between 0 and 1000 …

OrthodonticsMaterials scienceOsteosynthesisTension band wiringOlecranonElbowBiomedical Engineeringmedicine.diseaselaw.inventionIntramedullary rodmedicine.anatomical_structureOlecranon fracturelawFracture fixationmedicineDisplacement (orthopedic surgery)Biomedizinische Technik/Biomedical Engineering
researchProduct