Search results for "Orthopedic Surgery"

showing 10 items of 371 documents

Differences in gait characteristics between total hip, knee, and ankle arthroplasty patients: a six-month postoperative comparison.

2013

International audience; BACKGROUND: The recovery of gait ability is one of the primary goals for patients following total arthroplasty of lower-limb joints. The aim of this study was to objectively compare gait differences of patients after unilateral total hip arthroplasty (THA), total knee arthroplasty (TKA) and total ankle arthroplasty (TAA) with a group of healthy controls. METHODS: A total of 26 TAA, 26 TKA and 26 THA patients with a mean (+/- SD) age of 64 (+/- 9) years were evaluated six months after surgery and compared with 26 matched healthy controls. Subjects were asked to walk at self-selected normal and fast speeds on a validated pressure mat. The following spatiotemporal gait …

Malemusculoskeletal diseasesmedicine.medical_specialtySports medicineKnee Jointmedicine.medical_treatmentArthroplasty Replacement HipWalkingArthroplasty[ SDV.MHEP.RSOA ] Life Sciences [q-bio]/Human health and pathology/Rhumatology and musculoskeletal systemArthroplasty Replacement AnklePhysical medicine and rehabilitationPostoperative ComplicationsRheumatologyInternal medicineMedicineHumansOrthopedics and Sports MedicineKneeRange of Motion ArticularArthroplasty Replacement KneeGaitAged[SDV.MHEP.RSOA] Life Sciences [q-bio]/Human health and pathology/Rhumatology and musculoskeletal systemHipbusiness.industryMiddle Agedmusculoskeletal systemArthroplastyGaitRheumatologysurgical procedures operativemedicine.anatomical_structureOrthopedic surgeryExercise TestFemaleHip JointAnkleAnklebusinessCadenceRange of motionhuman activitiesAnkle JointResearch Article
researchProduct

Validity of five foot and ankle specific electronic patient-reported outcome (ePRO) instruments in patients undergoing elective orthopedic foot or an…

2019

Background: Patient-reported outcomes (PROS) are widely accepted measures for evaluating outcomes of surgical interventions. As patient-reported information is stored in electronic health records, it is essential that there are valid electronic PRO (ePRO) instruments available for clinicians and researchers. The aim of this study was to evaluate the validity of electronic versions of five widely used foot and ankle specific PRO instruments. Methods: Altogether 111 consecutive elective foot/ankle surgery patients were invited face-to-face to participate in this study. Patients completed electronic versions of the Foot and Ankle Ability Measure (FAAM), the Foot and Ankle Outcome Score (FAOS),…

MalepsychometricsVisual Analog Scaleclinimetricsleikkaushoito0302 clinical medicineSurveys and QuestionnairesElectronic Health RecordsOrthopedics and Sports MedicinePatient-reported outcomevalidation030222 orthopedicsMiddle AgedElectronic patient-reported outcomePRO MEASURES3. Good healthpsykometriikkamedicine.anatomical_structureConvergent validityvalidointiFemalePatient-reported outcomeEQUIVALENCEFoot (unit)medicine.medical_specialtyPsychometricsVisual analogue scaleQUESTIONNAIREpatient-reported outcomeVALIDATIONANALOG SCALE FOOTePRO03 medical and health sciencesClinimetricsanklemedicineQUALITYCOSMINHumansPatient Reported Outcome MeasuresFootbusiness.industryReproducibility of ResultsConstruct validity030229 sport sciences3126 Surgery anesthesiology intensive care radiologyjalatSurgerySYSTEMATIC REVIEWSnilkathoitotuloksetfootOrthopedic surgeryPAPERAnkleAnklebusinessAnkle JointTASK-FORCEFoot and Ankle Surgery
researchProduct

Experimental Study Regarding of Bending Behaviour of Stabilizator Link

2016

Abstract This paper presents an experimental study of the behavior of anti-roll power link subjected to bending, power link coming from an Opel Astra G. The power link is made of PA66 GF30 polyamide. For this study, there were used a universal testing machine (Instron 5587) and a real-time strain measurement optical system (Aramis). The results showed are those obtained in the case of a compression force of 1,000 [N] namely: major Strain ε1, minor strain ε2, equivalent von Mises strain, displacement on X axis, displacement on Y axis (compression force direction), displacement on Z axis.

Materials sciencebusiness.industryDisplacement (orthopedic surgery)General MedicineStructural engineeringBendingbusinessLink (knot theory)ACTA Universitatis Cibiniensis
researchProduct

Vertical bone augmentation procedures: Basics and techniques in dental implantology

2013

An appropriate bony situation is essential for dental implant placement and bony support of soft tissues (pink esthetic). Loss of teeth often results in complex horizontal and vertical alveolar ridge defects. They demand advanced bone augmentation techniques for reconstruction. We present the different techniques and materials used in complex bone augmentation. Clinical cases show the application of the methods in the clinical setting. We present current techniques and materials used in complex bone augmentations. Clinical cases show the application of the methods in the clinical setting. Applied techniques include stabilized-guided bone regeneration (GBR), autologous local block augmentati…

Materials sciencemedicine.medical_treatmentMetals and AlloysBiomedical EngineeringSoft tissueBiomaterialsmedicine.anatomical_structureCeramics and CompositesAlveolar ridgemedicineCortical boneBone regenerationDental implantCancellous bonePiezosurgeryReduction (orthopedic surgery)Biomedical engineeringJournal of Biomedical Materials Research Part A
researchProduct

Accidental displacement and migration of endosseous implants into adjacent craniofacial structures: A review and update

2011

Objectives: Accidental displacement of endosseous implants into the maxillary sinus is an unusual but potential complication in implantology procedures due to the special features of the posterior aspect of the maxillary bone; there is also a possibility of migration throughout the upper paranasal sinuses and adjacent structures. The aim of this paper is to review the published literature about accidental displacement and migration of dental implants into the maxillary sinus and other adjacent structures. Study Design: A review has been done based on a search in the main on-line medical databases looking for papers about migration of dental implants published in major oral surgery, periodon…

Maxillary sinusmedicine.medical_treatmentDentistryForeign-Body Migrationotorhinolaryngologic diseasesmedicineHumansDisplacement (orthopedic surgery)Dental implantGeneral DentistryDental Implantsmedicine.diagnostic_testbusiness.industryDental Implantation EndosseousSkullReview-ArticleMaxillary Sinus:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseEndoscopyParanasal sinusesmedicine.anatomical_structureOtorhinolaryngologyFaceUNESCO::CIENCIAS MÉDICASSurgeryImplantOral SurgeryForeign bodybusinessOrbit (anatomy)Medicina Oral Patología Oral y Cirugia Bucal
researchProduct

Mehrsegmentale Fusion der Skoliose bei Duchenne-Muskeldystrophie

2008

Operations in scoliosis in patients suffering from an advanced stage of Duchenne muscular dystrophy are associated with a higher risk due to the extent of the curves, the respiratory insufficiency and frequent cardiomyopathia. Progressive scolioses in 20 wheelchair patients with an age between 10.5-18.3 years (mean 14.6 years) were treated by CDI. The mean preoperative angle in this group was 70.6 degrees, the postoperative angle 31.2 degrees (mean correction 39.4 degrees or 55.8%). The preoperative lordosis of the lumbar spine (mean angle 4.1 degrees) was corrected to 17.8 degrees postoperatively. The average intraoperative blood loss (2300 ccm) was evident more compared with idiopathic sc…

Mechanical ventilationmedicine.medical_specialtyLordosisCobb anglebusiness.industrymedicine.medical_treatmentArthrodesisDuchenne muscular dystrophyScoliosismedicine.diseaseSurgeryOrthopedic surgerymedicineOrthopedics and Sports MedicineSurgerybusinessRachisZeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Analysis of the conflicts of interest disclosed by the program reviewers of the scoliosis research society (SRS) congresses, 2010-2014.

2018

Background Conflicts of interest (COI) between industry and surgeons frequently introduce biases into surgical research. The abstracts submitted for presentation in scientific congresses are usually vetted for any indication of commercial bias. Members of review program committees regularly have recognized qualifications, and therefore certain COI are unavoidable. This study aims to determine the prevalence and magnitude of possible COI among those responsible for the selection of presentations at two important international conferences on spine surgery during a five-year period. Methodology COI declarations by those responsible for the final programs of the annual SRS (Scoliosis Research S…

Medical DoctorsMedical ImplantsEconomicsHealth Care ProvidersOrthopedic Surgerylcsh:MedicineSocial Sciences0302 clinical medicineSpine surgeryShareholderMedicine and Health SciencesMedical Personnellcsh:ScienceMusculoskeletal SystemReimbursementSocieties MedicalSurgical research030222 orthopedicsMultidisciplinaryProfessionsScoliosisEngineering and TechnologyAnatomyResearch ArticleBiotechnologymedicine.medical_specialtyAdvisory CommitteesMEDLINESurgical and Invasive Medical ProceduresBioengineeringmacromolecular substances03 medical and health sciencesHealth EconomicsMusculoskeletal System ProceduresPolitical sciencePhysiciansparasitic diseasesmedicineHumansSpinal implantSurgeonsConflict of InterestResearchlcsh:RfungiConflict of interestBiology and Life SciencesCongresses as TopicSpineHealth CareFamily medicinePeople and Placeslcsh:QPopulation GroupingsMedical Devices and Equipment030217 neurology & neurosurgeryFinance
researchProduct

A new perspective on CMS – testing the effect of camera displacement in a realistic lane-change task

2020

Medical TerminologyComputer sciencebusiness.industryPerspective (graphical)Displacement (orthopedic surgery)Computer visionArtificial intelligencebusinessMedical Assisting and TranscriptionTask (project management)Proceedings of the Human Factors and Ergonomics Society Annual Meeting
researchProduct

Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…

2021

Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…

Medicine (General)medicine.medical_specialtyIntraocular Lens Dislocationgenetic structuresmedicine.medical_treatmentIntraocular lensAfter cataractArticleCataractlate intraocular lens dislocationR5-920Postoperative ComplicationsLens Implantation IntraocularmedicineHumansProspective StudiesProspective cohort studyweak zonules; anterior capsule opening reduction; late intraocular lens dislocation; capsular tension ringReduction (orthopedic surgery)Lenses IntraocularPhacoemulsificationbusiness.industryweak zonulescapsular tension ringGeneral MedicinePhacoemulsificationCataract surgeryLens Subluxationmedicine.diseaseComorbidityeye diseasesSurgeryanterior capsule opening reductionsense organsbusinessMedicina
researchProduct

Sevoflurane-induced reduction of bispectral index does not affect human cerebral microcirculation

2015

Methyl EthersTime FactorsIntraoperative Neurophysiological Monitoringmedicine.medical_treatmentAffect (psychology)SevofluraneSevoflurane03 medical and health sciencesConsciousness Monitors0302 clinical medicinePredictive Value of Tests030202 anesthesiologyGermanymedicineHumansAnesthesiaCerebral microcirculationReduction (orthopedic surgery)Cross-Over Studiesbusiness.industryMicrocirculationReproducibility of ResultsElectroencephalographySignal Processing Computer-AssistedBrain WavesAnesthesiology and Pain MedicineCerebrovascular CirculationBispectral indexAnesthesiaAnesthetics InhalationbusinessAlgorithmsCraniotomy030217 neurology & neurosurgerymedicine.drugEuropean Journal of Anaesthesiology
researchProduct