Search results for "Orthopedics"
showing 10 items of 2543 documents
The distribution of cartilage thickness in the knee-joints of old-aged individuals -- measurement by A-mode ultrasound.
1997
Abstract Objective. To provide data on the normal distribution of cartilage thickness in the knee joints of old-aged individuals. Design. The accuracy and reproducibility of cartilage thickness measurements were evaluated with A-mode ultrasound, and the cartilage thickness distribution was examined throughout both knee joints of nine individuals aged between 62 and 94 yr. Background. Data on the variation of cartilage thickness in the joint surfaces are relevant for the design of computer models of diathrodial joints and for surgical and arthroscopic procedures, particularly the calculation of cartilage material properties from indentation tests. Methods. A 12.5 MHz A-mode ultrasound transd…
The impact of multilevel surgery on functional abilities and participation in adolescents with cerebral palsy (CP)
2013
but not significant decrease in RT group. Timing of pKFSw, range of knee flexion and knee flexion velocity improved after surgery but tended to deteriorate over the years in either group. Discussionandconclusions:The results of thepresent study for the first time suggest that the influences of proximal RF release on DRFT effects on the knee joint are negligible. Two possible explanations shouldbe considered. First, thefindingsmaybe explainedby a permanent eliminationofRF functionon thekneeafterDRFT,which would be unaffected by proximal release and would underline the efficiency of DRFT. Secondly, surgery in the proximal part does not influence the distal part. This would represent a new imp…
Reaction of the bone structure to methotrexate-Palacos flow y. Experimental investigations in animals.
1989
With the combined osteosynthesis of pathological fractures in association with tumors and/or metastases in mind, E. Merck (Darmstadt, FRG) developed a bone cement containing a cytostatic agent, methotrexate-Palacos flow y (MTX-Pf). The animal-experimental study presented here investigates the tolerability of MTX-Pf in the femurs of rabbits with lateral comparison. In these investigations we used both the concentration of 0.63% MTX, as is currently used in standard clinical surgery, as well as a much higher concentration of 2.5% MTX. The histological sections were investigated using microradiographic methods and provided no indication of any significant differences between the femora with th…
Does hysterectomy with ovarian conservation affect bone metabolism and density?
2002
We evaluated whether hysterectomy with ovarian conservation (HYX) has an effect on bone metabolism and density in 176 healthy Caucasian postmenopausal women aged 48-59 years. Bone properties of the hip, spine, radius, tibia, and calcaneus were measured using different bone assessment modalities. In addition, bone turnover was assessed using serum bone-specific alkaline phosphatase (BAP), osteocalcin (OC), and tartrate-resistant acid phosphatase (TRAP) 5b as biomarkers. Our results showed that women having HYX had a significantly lower level of OC ( P = 0.017) and a marginally lower level of TRAP 5b ( P = 0.051) and higher bone mineral density (BMD) of the femoral neck ( P = 0.037) and lumba…
The PROMISE study protocol: a multicenter prospective study of process optimization with interdisciplinary and cross-sectoral care for German patient…
2021
Background and purpose — Knee and hip replacement are common and increasing procedures, and an optimized care process that could be implemented in different settings would be useful. The PROMISE trial investigates whether a new care process works equally in different German settings and how the results compare with current non-standardized care. Patients and methods — This multi-center prospective mixed-method study includes 2,000 German patients receiving arthritis-related hip or knee endoprostheses. An interdisciplinary and cross-sectoral care process was developed and implemented in 3 German hospitals with different levels of care, and corresponding rehabilitation centers were included t…
Impingement of the Sciatic Nerve due to a Protruding Acetabular Cage Rim
2020
Abstract Sciatic nerve damage is a well-known complication that occurs in 1.5% of patients after primary total hip arthroplasty and in 8% after revision total hip arthroplasty. Yet when considering re-revision arthroplasty and acetabular cage implantation, incidence and management remain unclear. This case report describes a young female patient with sciatic nerve impingement after acetabular cage implantation. Her primary complaint was shooting sciatic left leg pain, worsening on ambulation and when seated. A complete workup was negative for spinal impingement or infection, and axonal nerve damage was confirmed through nerve conduction studies. The intraoperative findings showed that it wa…
The Epidemiology of Hip and Knee Primary and Revision Arthroplasties during the COVID-19 Pandemic
2021
Background: The purpose of this study was to provide a comprehensive assessment of the impact of the COVID-19 pandemic on the epidemiology of primary and revision arthroplasties of the hip and knee joint. Methods: This study compared the data on knee and hip arthroplasty procedures from 2 hospitals (primary and revision) conducted in two periods: the period of the COVID-19 pandemic in Poland (from 4 March 2020 to 15 October 2020) and the corresponding period prior to the pandemic (from 4 March 2019 to 15 October 2019). We compared the epidemiological data, demographic data, and hospital stay duration data from these two periods. Results: Our analysis demonstrated that the total number of hi…
Optimal positioning of the humeral component in the reverse shoulder prosthesis.
2014
Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…
Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences
2020
Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…
Patient Specific Instrumentation for Total Knee Arthroplasty: a Literature Review
2014
During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient’s knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instru…