Search results for "Osseointegration"
showing 10 items of 130 documents
In vitroassessment of the biological response of Ti6Al4V implants coated with hydroxyapatite microdomains
2016
Dental implantology is still an expanding field of scientific study because of the number of people that receive dental therapies throughout their lives worldwide. Recovery times associated to dental surgery are still long and demand strategies to improve integration of metallic devices with hard tissues. In this work, an in vitro ceramic coating is proposed to improve and accelerate osseointegration of titanium surfaces conceived to be used as dental implants or hip or knee prosthesis, shaped either as dishes or screws. Such coating consists of hydroxyapatite microdomains on the implant surfaces obtained in vitro by immersion of titanium alloy samples (Ti6Al4V) in a simulated body fluid. T…
Influence of platelet-derived growth factor on osseous remodeling properties of a variable-thread tapered dental implant in vivo
2016
Objectives To evaluate the effect of platelet-derived growth factor (rhPDGF-BB) on the promotion of osteogenesis around variable-thread tapered implants in an animal model. Material and methods Twenty-four variable-thread tapered implants were inserted in the tibia of 12 rabbits. Twelve sites received additional rhPDGF-BB released from a presoaked xenogenic bone block that was fixed supracrestally. Primary outcomes were bone-to-implant contact (BIC; in % ± SD) and percentage of medullary bone fill around the implants (PMF; in % ± SD) after 3 weeks (PDGF n = 6, no PDGF n = 6) and 6 weeks (PDGF n = 6, no PDGF n = 6). Results Considerable crestal and medullary bone remodeling could be found ar…
Multidisciplinary oral rehabilitation in partially edentulous adult patients with malocclusion: a cross-sectional survey study
2018
Background A cross-sectional survey was conducted to gather information regarding the opinion of Brazilian specialists in both orthodontics and implantology on multidisciplinary oral rehabilitation in partially edentulous patients with malocclusion. Material and methods A total of 305 specialists participated in a telephone survey and answered an ad hoc 10-item questionnaire, including the request of total skull cone-beam tomographies (CBCT) and the use of 3D digital planning software, the best moment of treatment to place dental implants, and the integration of orthodontics in implantology. Results Most participants did not request CBCT (90.8%) or 3D digital planning software images (92.3%…
On the use of the electromechanical impedance technique for the assessment of dental implant stability: Modeling and experimentation
2014
We propose the electromechanical impedance technique to monitor the stability of dental implants. The technique consists of bonding one wafer-type piezoelectric transducers to the implant system. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer’s electrical admittance. The hypothesis is that the health of the bone surrounding the implant affects the sensor’s admittance. A three-dimensional finite element model of a transducer bonded to the abutment of a dental implant placed in a host bone site was created to simulate the progress of the tissue healing that occurs after surgery. The healing was modeled by changing the …
Bone-to-implant contact of orthodontic implants in humans--a histomorphometric investigation
2008
The purpose of the present study was to evaluate the percentage of direct bone-to-implant contact (BIC) of orthodontic anchorage implants (Orthosystem) after active orthodontic treatment. Twenty orthodontic implants (diameter, 3.3 mm; length, 4 or 6 mm) were inserted for orthodontic anchorage in different anatomical regions of 18 adult patients (nine males, nine females) aged 18-63 years. Fifteen implants (one per patient) were placed in the mid-palatal area, one implant (one patient) in the retromolar area of the mandible, one in the retromolar area and the mid-palatal area (one patient), and two (bilaterally, one patient) in the zygomatic area. The duration of the unloaded healing period …
Vertical Mandibular Alveolar Bone Distraction and Dental Implant Placement: A Case Report
2006
Abstract Extensive bone defects complicate the adequate placement of dental implants and the required angulation. In such cases, alveolar-ridge augmentation techniques such as guided bone regeneration, particulate or block grafting, and alveolar bone distraction are needed. The present study describes a case in which a large vertical bone defect in the anterior mandibular zone was corrected via vertical alveolar bone distraction. Six dental implants were posteriorly placed for implant-supported restoration of the mandible, with early implant loading. The clinical and radiologic control showed good implant and soft tissue conditions 12 months later.
Effect of undersized drilling on the stability of immediate tapered implants in the anterior maxillary sector. A randomized clinical trial.
2020
Background To evaluate the effect of undersized drilling on the primary and secondary stability of immediate implants placed in the anterior maxilla. Material and Methods A comparative randomized clinical trial was carried out in 30 healthy adults. Thirty tapered implants, 16 involving conventional drilling and 14 undersized drilling, were placed immediately after anterior maxillary tooth removal. Insertion torque and implant stability assessed by resonance frequency analysis (RFA) were evaluated at three different timepoints: at implant placement and 6 and 12 weeks post-implantation. The results were compared using parametric statistical tests. Results All implants showed adequate stabilit…
Mandibular connective tissue pedicle flaps in implant dentistry: report of three cases.
2007
Abstract An increase in soft tissues and alveolar bone in the anterior mandibular area between the canines is necessary to achieve a good esthetic result. The present article describes a technique for gaining bone volume and soft tissue to cover bone defects that would otherwise compromise the final result of prosthetic implant restoration in the anterior mandible. Three patients with anterior mandibular atrophy caused by loss of the mandibular incisors are presented. Particulate autologous bone grafting, the raising of a pediculate connective tissue flap to increase soft tissue, and implant placement were carried out simultaneously. After 2 years of follow-up, the implants were in good cli…
Vertical guided bone regeneration with bioabsorbable barriers.
2007
Guided bone regeneration (GBR) is a very useful surgical technique to increase limited alveolar bone for implant placement. The use of non-resorbable barriers is well established; however, bioabsorbable collagen membranes may simplify the surgical technique and make it more predictable.Vertical ridge augmentation was performed on 11 patients at the time of implant placement. The part of the implant out of bone was covered with autogenous bone/graft, and a slow-resorption collagen membrane was placed on top. Gingival tissues were closed with horizontal mattress and interrupted sutures. Second-stage surgery was performed 4 to 6 months later, and healing abutments were placed. The length of th…
Use of autologous tooth-derived graft material in the post-extraction dental socket. Pilot study
2019
Background The objectives of the present pilot study are to compare via CBCT the alveolar contraction suffered both vertically and horizontally between the control group and the group using autologous dental material (ADM), as well as to study the densitometric differences between both post-extraction sockets. Material and Methods A split-mouth study was performed in n = 9 patients who required two extraction of single-rooted teeth deemed suitable for deferred rehabilitation with osseointegrated implants. Two groups were formed — a control group, in which the post-extraction socket was not filled, and an ADM group, in which the alveolar defect was filled with freshly processed autogenous de…