Search results for "Osseointegration"
showing 10 items of 130 documents
Introduction to Immediate Loading in Implantology
2019
Branemark traditional recommendation was to perform implant rehabilitation in two stages: the first entry was only for implant placement; after 3–6 months of undisturbed submerged healing for mandible and maxilla, respectively, a second surgical entry would have allowed loading of the implants. The rationale behind this approach was that implant micro-movements as consequence by an inadequate primary stability, caused by functional forces at the bone-implant interface in the early wound healing stages, could have induced fibrous tissue formation rather than new bone, eventually causing clinical failure. The main request was to reduce the overall rehabilitation time from surgery to final res…
Vertical Osteoconductive Characteristics of Titanium Implants with Calcium-Phosphate-Coated Surfaces - A Pilot Study in Rabbits
2014
Introduction: Osteoconductive characteristics of different implant surface coatings are in the focus of current interest. The aim of the present study was to compare the vertical osteoconductivity at the implant shoulder of supracrestal inserted calcium-phosphate coated implants (SLA-CaP) with conventional sand-blasted/acid-etched (SLA) implants in a rabbit model. Materials and Methods: SLA-CaP and SLA implants were inserted bilaterally in the mandible of four rabbits in a split-mouth design. The implants were placed 2 mm supracrestal. After 3 weeks, at the left and right implant shoulder, the percentage of linear bone fill (PLF) as well as bone-implant contact (BIC-D) were determined. Resu…
Relation between bone density and primary implant stability
2010
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was obs…
Thermal increment due to ErCr: YSGG and CO2 laser irradiation of different implant surfaces. A pilot study
2010
Podeu consultar la versió en castellà http://hdl.handle.net/2445/118903
Periapical implant lesion: A systematic review.
2016
Background The aim of this study was to systematically review the evidence for periapical implant lesion, which makes a patient more susceptible to the periapical lesion, frequency, symptoms, signs (including radiological findings) and possible treatment options. Material and Methods A systematic literature review and analysis of publications included in PubMed, Embase and Cochrane; articles published until March 2016; with a populations, exposures and outcomes (PEO) search strategy was performed, focused on the issue: “In patients with periapical lesion to the implant during the osseointegration, what symptoms, signs, and changes in complementary examination manifested, for according to th…
Comparison of peri-implant soft tissues in submerged versus transmucosal healing: A split mouth prospective immunohistochemical study
2018
Objective The present split-mouth prospective study involves an immunohistochemical evaluation of peri-implant soft tissue healing after the osseointegration period, comparing submerged and transmucosal approaches using two-piece implant systems. The null hypothesis was that both surgical procedures elicit a similar immune response of the peri-implant soft tissues. Design Thirty-one healthy patients were included in this study, in which two implants were placed in the right and left maxillary pre-molar regions. A total of 62 dental implants were analyzed, establishing a control side with 31 submerged implants, and a study side with 31 exposed implants bearing healing abutments. After a thre…
Orthodontic load on short maxillary implants with reduced sink depth: an experimental study.
2008
Objective The aim of this study was to investigate experimentally the positional stability and histomorphometric findings of length-reduced temporary anchorage devices (Orthosystem, length: 4 mm) with reduced sink depth. Material and methods For this purpose, four maxillary pre-molars ((2)P(2), (3)P(3)) were extracted from each of four foxhounds. After a 16-week alveolar healing period, 16 implants (four per dog) were inserted into the edentulous areas. Four implants (one per dog) were placed simultaneously in the mid-palatal area. The implants were intentionally submerged to about three-quarters of their length. After a 10-week unloaded implant healing period, the implants in the P3 areas …
Drilling dimension effects in early stages of osseointegration and implant stability in a canine model
2015
Background: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Material and Methods: Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linea…
Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in she…
2015
Background This study aimed to compare the histomorphometric and histological bone response to laser-sintered implants followed by resorbable-blasting media (RBM) process relative to standard machined/RBM surface treated implants. Material and Methods Six male sheep (n=6) received 2 Ti-6Al-4V implants (1 per surface) in each side of the mandible for 6 weeks in vivo. The histomorphometric parameters bone-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Results Optical interferometry revealed higher Sa and Sq values for the laser-sintered/RBM surface in relation to standard/RBM implants. No significant differences in BIC were observed between the two groups (p>0.2…
Immunohistochemical characteristics of the Implant-Hosted Bon : preliminary findings of 9 mandibular cores
2010
Objectives: The aims of this study were to investigate the biochemical topography of collagen types I and III and to describe the histological structure at the implant placement site to determine the clinical significance of the findings and their possible interaction with bone healing around dental implants. Material and Methods: Bone cores from 9 mandibles were taken from the site of placement of dental implants. The reliable technique for rapid preparation of fresh-frozen undecalcified bone sections and the indirect immunofluorescent technique as an immunohistochemical procedure were applied. All sections were viewed under U.V light. For comparative purposes the tissue blocks remaining w…