Search results for "Oxybenzone"

showing 6 items of 6 documents

Determination of butyl methoxydibenzoylmethane, benzophenone-3, octyl dimethyl PABA and octyl methoxycinnamate in lipsticks.

2003

The complex composition of lipstick formulations usually needs the use of organic solvents for sample dissolution. A treatment based on dissolution of cosmetic samples in ethanol-water (70 : 30, v/v) by use of ultrasonic irradiation is proposed. A C(18) stationary phase and an isocratic mobile phase of ethanol:water:acetic acid (70 : 29.5 : 0.5, v/v/v) with a flow rate of 1 mL min(-1) and an injection volume of 20 microL is proposed for the high-pressure liquid chromatography (HPLC) determination of four UV-filters, and detection was carried out at 309 nm. The limit of the chromatographic detection was 7.0 microg mL(-1) for butyl methoxydibenzoylmethane, 1.5 microg mL(-1) for benzophenone-3…

AgingChromatographyEthanolPharmaceutical ScienceOctyl methoxycinnamateDermatologyLipstickHigh-performance liquid chromatographyAcetic acidchemistry.chemical_compoundColloid and Surface ChemistrychemistryChemistry (miscellaneous)Drug DiscoveryBenzophenoneOxybenzoneTetrahydrofuranInternational journal of cosmetic science
researchProduct

Simultaneous determination of oxybenzone and 2-ethylhexyl 4-methoxycinnamate in sunscreen formulations by flow injection-isodifferential derivative u…

2001

Abstract A flow injection procedure was developed for the simultaneous determination of two UV filters (oxybenzone and 2-ethylhexyl 4-methoxycinnamate) in sunscreen formulations, based on the isodifferential approach. The use of the second derivative spectra allowed a selective determination of the analytes free from matrix interferences and without pretreatment of samples. Standard solutions of the analytes were analyzed by the proposed procedure in order to select the appropriate wavelengths to solve the mixture. After this, the procedure was validated using commercial sunscreen formulations the concentrations of which were determined by an HPLC procedure. The two procedures gave comparab…

Detection limitAnalyteChromatographyInjection ProcedureAnalytical chemistryDerivativeStandard solutionBiochemistryAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundchemistryEnvironmental ChemistryOxybenzoneSpectroscopySecond derivativeAnalytica Chimica Acta
researchProduct

Sequential injection spectrophotometric determination of oxybenzone in lipsticks

2001

A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. E…

Detection limitChromatographyChemistryExtraction (chemistry)CosmeticsBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow rateBenzophenoneschemistry.chemical_compoundVolume (thermodynamics)SpectrophotometryReagentElectrochemistryEnvironmental ChemistryOxybenzoneQuantitative analysis (chemistry)SpectroscopyThe Analyst
researchProduct

Determination of UV-filters in sunscreens by HPLC.

2001

Simultaneous determination of six internationally authorised organic UV-filters in sunscreen formulations was performed by HPLC with UV spectrophotometric detection. The filters determined were: sulisobenzone, oxybenzone, octyl dimethyl PABA, octyl methoxycinnamate, octyl salicylate and homosalate. A C18 stationary phase and a mobile phase of ethanol water acetic acid (70 : 29.5 : 0.5) were used with a flow rate of 0.5 mL/min. UV measurements were carried out at 313 nm. The time required for the analysis was 25 min and the limits of detection were between 0.2 and 2 mg/L, except for sulisobenzone, which gave a limit of detection of 20 mg/L. The procedure proposed provides an accurate, fast a…

Detection limitChromatographyUltraviolet RaysOctyl methoxycinnamateReversed-phase chromatographySulisobenzoneBiochemistryHigh-performance liquid chromatographyHomosalatechemistry.chemical_compoundchemistrymedicineOctyl salicylateIndicators and ReagentsOxybenzoneSunscreening AgentsChromatography High Pressure Liquidmedicine.drugFresenius' journal of analytical chemistry
researchProduct

Effect of hydraulic coefficient on membrane performance for rejection of emerging contaminants

2018

International audience; The efficient removal of Endocrine Disruptive Chemicals (EDCs) namely oxybenzone and atrazine using polysulfone (PSf) composite membranes is reported in this article. A negatively charged hydrophilic mixed matrix membrane was prepared by using Polyaniline modified halloysite nanotubes (PANi-HNT) and polysulfone. The X-ray diffraction (XRD) and attenuated total reflectance infrared (ATR-IR) technique confirm the conversion of Halloysite nanotubes to Polyaniline modified halloysite nanotubes and their presence in membrane matrix. The microvoids observable in the SEM images depict the internal structure of the membrane. Further, increasing in the water uptake and decrea…

Materials scienceGeneral Chemical Engineering02 engineering and technologyGeneral Chemistry010501 environmental sciencesengineering.material021001 nanoscience & nanotechnology01 natural sciencesHalloysiteIndustrial and Manufacturing EngineeringContact anglechemistry.chemical_compoundMembraneAdsorptionchemistryChemical engineeringAttenuated total reflectionPolyanilineengineeringEnvironmental ChemistryPolysulfoneOxybenzone0210 nano-technology[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]0105 earth and related environmental sciences
researchProduct

Efficient flow injection and sequential injection methods for spectrophotometric determination of oxybenzone in sunscreens based on reaction with Ni(…

2001

Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LO…

Reaction conditionsChromatographymedicine.diagnostic_testColor reactionAnalytical chemistryBiochemistryHigh-performance liquid chromatographySensitivity and Specificitychemistry.chemical_compoundSequential injectionBenzophenoneschemistryAmmoniaNickelSpectrophotometrySpectrophotometrymedicineIndicators and ReagentsOxybenzoneQuantitative analysis (chemistry)Sunscreening AgentsStoichiometryChromatography High Pressure LiquidFresenius' journal of analytical chemistry
researchProduct