Search results for "PESTICIDE"
showing 10 items of 588 documents
Evaluation of working air quality by using semipermeable membrane devices
2008
Abstract It has been evaluated the use of semipermeable membrane devices (SPMDs) as passive samplers of organophosphorus pesticides from air, in order to determine the contamination of working environments. Additionally, the use of SPMDs as portable samplers has been also considered. The analytical methodology for the determination of diazinon, chlorpyrifos-methyl, pirimiphos-methyl, chlorpyrifos and fenthion in SPMDs exposed to contaminated air was based on microwave-assisted extraction and gas chromatography with mass spectrometry determination. Limit of detection (LOD) values from 2 to 4 ng SPMD−1 and repeatability from 2 to 7% were obtained by using the aforementioned methodology. Theor…
A chemiluminescence flow-based procedure for determination of carbaryl in natural waters exploiting multicommutation and enzymatic reaction
2007
A chemiluminescence procedure for the determination of carbaryl in natural waters using acetylcholinesterase and choline oxidase is described. The flow system designed to implement multicommutation approach controlled by microcomputer comprised five solenoid valves, two columns with immobilized enzymes on controlled pore glass beads and chemiluminometric flow cell. In the best experimental conditions a linear response ranging from 25 to 700 µg L-1 carbaryl was obtained. Water samples were spiked with carbaryl in order to access the accuracy and recoveries between 95 and 101% were obtained for a concentration level ranging from 25 to 100 µg L-1 carbaryl. Detection limit and variation coeffic…
Uptake and translocation monitoring of imidacloprid to chili and tomato plants by molecularly imprinting extraction - ion mobility spectrometry
2019
Abstract The degradation of imidacloprid in soil and its uptake and translocation to chili and tomato plants was evaluated, as a proof of concept, of the possibilities of the combination of molecularly imprinted polymers (MIPs) and ion mobility spectrometry (IMS) for a fast and sensitive bioprocesses monitoring tool. To do it, a method based on the selective extraction of imidacloprid from soil and plant materials was developed. In the selected conditions, the MIP-IMS procedure provided a recovery of imidacloprid in soil and plant samples from 102 to 114%, for spiked concentration levels from 0.2 to 2.0 μg g−1. Precision of the methodology, expressed as the relative standard deviation (RSD)…
Fourier transform infrared determination of imidacloprid in pesticide formulations
2004
A simple method has been developed for Fourier Transform Infrared (FTIR) determination of Imidacloprid in pesticide formulations. Samples were diluted with CHCl3 and the FTIR spectra of samples and standards were obtained at a nominal resolution of 4 cm-1 from 4000 to 900 cm-1 accumulating 25 scans. Imidacloprid determination was based on the measure of either peak area from 1577 to 1567 cm-1 or peak height at 1572 cm-1, both corrected using a horizontal baseline defined at 1900 cm-1. The limits of detection achieved, of the order of 9 µg g-1, were appropriate for the determination of Imidacloprid in commercially available formulations. FTIR results were statistically comparable to those fo…
Determination of amitraz and its transformation products in pears by ethyl acetate extraction and liquid chromatography-tandem mass spectrometry.
2008
A method has been developed for identification and quantification of the acaricide amitraz and its transformation products, 2,4-dimethylaniline (DMA), 2,4-dimethylformamidine (DMF) and N-2,4-dimethylphenyl-N-methylformamidine (DMPF) in pears. The analytes were extracted using ethyl acetate and anhydrous sodium sulphate. Analysis was performed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) in the positive ion mode using a triple quadrupole (QqQ) instrument. Two precursor-product ion transitions were monitored for each compound in the selected reaction monitoring (SRM) mode. The method was validated with pears taken from the orchard before the amitraz treatment …
Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis: An overview
2003
An overview is given on pesticide-residue determination in environmental and food samples by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). Pesticides comprise a large number of substances that belong to many completely different chemical groups, the only common characteristic is that they are effective against pests. They still constitute a challenge in MS because there is no collective pathway for fragmentation. A brief introduction to the theory of tandem MS permits a discussion of which parameters influence the ionization efficiency when the ions are subjected to different actions. Emphasis is placed on the different tandem MS instruments: triple and ion-trap quad…
Rapid and sensitive ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry for the quantification of amitraz and ident…
2008
Liquid chromatography under high pressure in combination with quadrupole time-of-flight mass spectrometry (QqTOF-MS and MS/MS) has been used to detect amitraz degradation products in pears, to characterize their structures, and to evaluate their occurrences in samples of different origins. Using the proposed approach, the parent pesticide and four degradation products were identified. To this end, pear samples were extracted with ethyl acetate and anhydrous sodium sulphate. Amitraz was found to be rapidly decomposed into four related compounds, of which N-(2,4-dimethylphenyl)formamidine (DMPF) was the most abundant and persistent. N,N'-bisdimethylphenylformamidine (BDMPF), 2,4-dimethylforma…
Development of monoclonal antibody-based competitive immunoassays for the detection of picoxystrobin in cereal and oilseed flours
2012
Picoxystrobin is a new generation fungicide primarily developed to be used in cereal crops. In the present study a novel collection of specific monoclonal antibodies has been produced using different immunizing haptens based on a carboxy-functionalized identical spacer arm attached to alternative positions of the target pesticide molecule. Two competitive enzyme-linked immunosorbent assays have been developed employing hapten heterology, one using the antibody-coated direct format and the other in the conjugate-coated indirect format. Both immunoassays have been characterized in terms of selectivity, solvent tolerance, and buffer conditions, affording similar limits of detection at or below…
An Infrared Method, with Reduced Solvent Consumption, for the Determination of Chlorsulfuron in Pesticide Formulations
2003
A simple method has been developed for the determination of Chlorsulfuron in pesticide formulations by Fourier Transform Infrared (FTIR). Samples were diluted with CHCl3− , and the FTIR spectra of the samples and standards were obtained at a nominal resolution of 4 cm− 1 from 4000 to 900 cm− 1 with the accumulation of 25 scans. Chlorsulfuron determination was based on the measurement of peak area values from 1373 to 1363 cm− 1 which were corrected by use of a two points baseline defined from 1401 to 1302 cm− 1. The limit of detection achieved, which was of the order of 6 µg g− 1, was appropriate for the determination of Chlorsulfuron in commercially available formulations. FTIR results were…
Determination of pesticides in soil samples by solid phase extraction disks
1993
A systematic study comparing the methodology and analytical results obtained in an investigation of seven pesticide residues (Molinate, Atrazine, Carbofuran, Pirimicarb, Prometryn, Malathion and Tetrachlorvinphos) in soil samples is reported. Solid-phase extraction (SPE) using glass columns and 47 mm disks of octyl and octadecyl-bonded silica was used in the pesticide analysis. The best extraction efficiency and clearest extracts are obtained with C8 disks. The analyses were carried out by capillary gas chromatography with nitrogen and phosphorus detection. Recovery experiments were performed at ppb levels in spiked soil samples. The average recoveries of the compounds were 53–77%. Detectio…