Search results for "PESTICIDE"
showing 10 items of 588 documents
Selection of sampling adsorbents and optimisation and validation of a GC-MS/MS method for airborne pesticides
2017
ABSTRACTA methodology for the sampling and determination of airborne pesticides has been developed. The trapping efficiency of three adsorbents, namely XAD-2,XAD-4 and a sandwich sorbent (PUF-XAD2-PUF), was tested for 34 pesticides and the latter was selected because it presented the highest retention capacity without breakthrough. Pesticides were determined by gas chromatography coupled to an ion trap mass spectrometer in tandem. The method showed recoveries ranging from 70% to 120% with limits of quantification in the range of 16.1–322.6 pg m−3 when 155 m3 were sampled. This analytical strategy was applied to 10 indoor air samples collected in dwellings from the Valencian Region. Six pest…
Design d'un iprodione-MIP (molecularly imprinted polymer) : application à la pré-concentration des fongicides dans le vin
2014
The aim of this study was the synthesis of a MIP (molecularly imprinted polymer) specific for a fungicide that is found in the majority of the french wine: iprodione. The challenge for extracting iprodione from wine medium was that the hydoralcoholic solution is a dipolar solvent, whereas the interaction between the MIP and iprodione is based on dipolar interactions. The first extraction study of iprodione was made on a MIP synthesized by bulk polymerization using methacrylamide and ethylene glycol dimethacrylate (EGDMA). The MIP was found to be more efficient than the NIP (non-imprinted polymer) in hydroalcoholic solutions which demonstrates that the molecular imprinting was successful. Th…
Comprehensive analytical strategy for biomonitoring of pesticides in urine by liquid chromatography–orbitrap high resolution mass spectrometry
2014
In this study we propose an analytical strategy that combines a target approach for the quantitative analysis of contemporary pesticide metabolites with a comprehensive post-target screening for the identification of biomarkers of exposure to environmental contaminants in urine using liquid chromatography coupled to high-resolution mass spectrometry (LC–HRMS). The quantitative method for the target analysis of 29 urinary metabolites of organophosphate (OP) insecticides, synthetic pyrethroids, herbicides and fungicides was validated after a previous statistical optimization of the main factors governing the ion source ionization and a fragmentation study using the high energy collision disso…
Routine application using single quadrupole liquid chromatography-mass spectrometry to pesticides analysis in citrus fruits.
2005
Abstract A rapid and sensitive liquid chromatography–electrospray ionization–mass spectrometry method has been developed for the routine analysis of buprofezin, bupirimate, hexaflumuron, tebufenpyrad, fluvalinate and pyriproxyfen in citrus fruits. Extracts were obtained by matrix solid-phase dispersion (MSPD) using C 18 as dispersant and dichloromethane-methanol (80:20, v/v) as eluent. Matrix effects were tested for all matrices by addition of standard to sample blank extracts (samples containing no detectable residues). Mean recoveries obtained at fortification levels between 0.01 and 5 mg kg −1 were 57–97% with relative standard deviations (RSDs) from 5 to 19%. The limits of quantificatio…
Liquid chromatography–electrospray quadrupole ion-trap mass spectrometry of nine pesticides in fruits
2004
A liquid chromatographic method, with electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS), has been developed for determining acrinathrin, carbosulfan, cyproconazole, lambda-cyhalothrin, kresoxim methyl, pyrifenox, pyriproxyfen, propanil, and tebufenpyrad in fruits. The ions prominent in ESI spectra were [M + H]+ and [M + Na]+. In the mass analyzer, collision-induced dissociation fragmentation involved common pathways, for example, product ions of [M + H]+ resulted from the cleavage of the carbamic group or an oxygen bound. The utility of the method is demonstrated by the analysis of crude extracts obtained by matrix solid-phase dispersion (MSPD) using C18 as dispersant and dich…
Pathogenicity of intrathoracically administrated Bacillus thuringiensis spores in Blatta orientalis.
2006
Abstract The ability of Bacillus thuringiensis to produce septicaemia in Periplaneta americana and Blatta orientalis has been investigated. Spores and crystals from several wild-type strains as well as spores of a B. thuringiensis crystal-deficient mutant, were first orally administrated at high doses, and no significant mortality was recorded. Intrathoracic injection of spore suspensions in P. americana revealed that this species is not very susceptible to B. thuringiensis spores. B. orientalis , by contrast, was found to be very susceptible to B. thuringiensis , with a LD 50 of about 35,000 spores, that is similar to that reported on Lepidoptera challenged with parenterally injected B. th…
Pesticide Effects on Eel Metabolism
1995
Previous works on endosulfan eel toxicology in this laboratory demonstrated that 0.041 mg/liter of endosulfan was the 50% lethal concentration of 96 hr exposure. Eels of species Anguilla anguilla were exposed to two sublethal endosulfan concentrations: 8.2 μg/liter (1/5 LC50) and 4.1 μg/liter (1/10 LC50), and the experiment was done at different exposure times: 12, 24, 48, 72, and 96 hr. Muscle glycogen content decreased significantly (P < 0.05) at 24, 48, 72, and 96 hr exposure to 8.2 μg/liter pesticide; levels did not decline at any time when animals were exposed to 4.1 μg/liter. Muscle lactate levels in fish did not change significantly while lactate levels in eel blood increased at 12, …
Multi-residue analysis of 30 currently used pesticides in fine airborne particulate matter (PM 2.5) by microwave-assisted extraction and liquid chrom…
2009
A confirmatory and rapid procedure has been developed for the determination of 30 currently used pesticides (CUP) in fine airborne particulate matter (PM 2.5) at trace level. The proposed method includes extraction of PM 2.5-bound pesticides by microwave-assisted extraction (MAE) followed by a direct injection into LC-MS/MS. The main parameters affecting the MAE extraction (time, temperature and volume of solvent) were optimised using statistical design of experiments (DoE). The matrix effect was also evaluated. Recoveries ranged from 72 to 109% and the limit of quantification (LoQ) was 32.5 pg m(-3) for chlorpyrifos, 13.5 pg m(-3) for fenhexamid, imazalil and prochloraz, and 6.5 pg m(-3) f…
Regulation of bacterial and fungal MCPA degradation at the soil–litter interface
2010
Abstract Much is known about mechanisms and regulation of phenoxy acid herbicide degradation at the organism level, whereas the effects of environmental factors on the performance of the phenoxy acid degrading communities in soils are much less clear. In a microcosm experiment we investigated the small-scale effect of litter addition on the functioning of the MCPA degrading communities. 14 C labelled MCPA was applied and the functional genes tfdA and tfdAα were quantified to characterise bacterial MCPA degradation. We identify the transport of litter compounds as an important process that probably regulates the activity of the MCPA degrading community at the soil–litter interface. Two possi…
Combined use of liquid chromatography triple quadrupole mass spectrometry and liquid chromatography quadrupole time-of-flight mass spectrometry in sy…
2012
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC-QqQ-MS/MS) and liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC-QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L(-1). Of the 43 selected pesticides, 33 were detected in water samples. The ESI-QTOF MS instrument was run using two simultaneous acquisi…