Search results for "PHOTONS"
showing 10 items of 164 documents
Direct observation of spin wave focusing by a Fresnel lens
2020
Spin waves are discussed as promising information carrier for beyond complementary metal-oxide semiconductor data processing. One major challenge is guiding and steering of spin waves in a uniform film. Here, we explore the use of diffractive optics for these tasks by nanoscale real-space imaging using x-ray microscopy and careful analysis with micromagnetic simulations. We discuss the properties of the focused caustic beams that are generated by a Fresnel-type zone plate and demonstrate control and steering of the focal spot. Thus, we present a steerable and intense nanometer-sized spin-wave source. Potentially, this could be used to selectively illuminate magnonic devices like nano-oscill…
Update on decaying and annihilating heavy dark matter with the 6-year IceCube HESE data
2019
In view of the IceCube's 6-year high-energy starting events (HESE) sample, we revisit the possibility that the updated data may be better explained by a combination of neutrino fluxes from dark matter decay and an isotropic astrophysical power-law than purely by the latter. We find that the combined two-component flux qualitatively improves the fit to the observed data over a purely astrophysical one, and discuss how these updated fits compare against a similar analysis done with the 4-year HESE data. We also update fits involving dark matter decay via multiple channels, without any contribution from the astrophysical flux. We find that a DM-only explanation is not excluded by neutrino data…
Coherent Excitation of Heterosymmetric Spin Waves with Ultrashort Wavelengths
2017
In the emerging field of magnonics, spin waves are foreseen as signal carriers for future spintronic information processing and communication devices, owing to both the very low power losses and a high device miniaturisation potential predicted for short-wavelength spin waves. Yet, the efficient excitation and controlled propagation of nanoscale spin waves remains a severe challenge. Here, we report the observation of high-amplitude, ultrashort dipole-exchange spin waves (down to 80 nm wavelength at 10 GHz frequency) in a ferromagnetic single layer system, coherently excited by the driven dynamics of a spin vortex core. We used time-resolved x-ray microscopy to directly image such propagati…
Spin texture of time-reversal symmetry invariant surface states on W(110)
2016
AbstractWe find in the case of W(110) previously overlooked anomalous surface states having their spin locked at right angle to their momentum using spin-resolved momentum microscopy. In addition to the well known Dirac-like surface state with Rashba spin texture near the "Equation missing"-point, we observe a tilted Dirac cone with circularly shaped cross section and a Dirac crossing at 0.28 × "Equation missing" "Equation missing" within the projected bulk band gap of tungsten. This state has eye-catching similarities to the spin-locked surface state of a topological insulator. The experiments are fortified by a one-step photoemission calculation in its density-matrix formulation.
Spectral energy distribution and generalized Wien's law for photons and cosmic string loops
2014
Physical objects with energy $u_w(l) \sim l^{-3w}$ with $l$ characteristic length and $w$ a dimensionless constant, lead to an equation of state $p=w\rho$, with $p$ the pressure and $\rho$ the energy density. Special entities with thisbproperty are, for instance, photons ($u = hc/l$, with $l$ the wavelength) with $w = 1/3$, and some models of cosmic string loops ($u =(c^4/aG)l$, with $l$ the length of the loop and $a$ a numerical constant), with $w = -1/3$. Here, we discuss some features of the spectral energy distribution of these systems and the corresponding generalization of Wien's law, which in terms of $l$ has the form $Tl_{mp}^{3w}=constant$, being $l_{mp}$ the most probable size of …
Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.
2020
The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…
Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data
2014
Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was…
Comparison between transmission and scattering spectrum reconstruction methods based on EPID images.
2013
Numerous improved physics-based methods for Linac photon spectra reconstruction have been published; some of them are based on transmission data analysis and others on scattering data. In this work, the two spectrum unfolding approaches are compared in order to experimentally validate its robustness and to determine which is the optimal methodology for application on a clinical quality assurance routine. Both studied methods are based on EPID images generated when the incident photon beam impinges onto plastic blocks. The distribution of transmitted/scatter radiation produced by this object centered at the beam field size was measured. Measurements were performed using a 6 MeV photon beam p…
Monte Carlo study of microdosimetric diamond detectors
2015
Ion-beam therapy provides a high dose conformity and increased radiobiological effectiveness with respect to conventional radiation-therapy. Strict constraints on the maximum uncertainty on the biological weighted dose and consequently on the biological weighting factor require the determination of the radiation quality, defined as the types and energy spectra of the radiation at a specific point. However the experimental determination of radiation quality, in particular for an internal target, is not simple and the features of ion interactions and treatment delivery require dedicated and optimized detectors. Recently chemical vapor deposition (CVD) diamond detectors have been suggested as …
A facility to validate photomultipliers for the upgrade of the Pierre Auger Observatory.
2020
The Pierre Auger Observatory is undergoing a major upgrade named AugerPrime with the primary aim to add sensitivity to the mass-composition discrimination of ultrahigh-energy cosmic rays. Two different photomultipliers will be added to each water-Cherenkov station of the surface detector of Observatory. To achieve the scientific goals of AugerPrime these photomultipliers have to ensure a linear response to input-light in a wide range. This paper describes a system developed for the validation of AugerPrime-photomultipliers.