Search results for "PLANTS"

showing 10 items of 1914 documents

Translational development and pre-clinical evaluation of prototype gastrointestinal mock-up devices: only robotic placement of plastic?

2020

Background: The aim of this study was to address the vision of wireless theranostic devices distributed along the gastrointestinal (GI) tract by defining design requirements, developing prototype mock-ups, and establishing a minimally invasive surgical approach for the implantation process. Methods: Questionnaires for contextual analysis and use case scenarios addressing the technical issues of an implantable GI device, a possible scenario for implantation, preparation and calibration of a device, and therapeutic usage by professionals and patients were completed and discussed by an interdisciplinary team of surgeons, engineers, and product designers. Two acute porcine experiments were cond…

medicine.medical_specialtySwineComputer scienceeducation0206 medical engineeringBiomedical Engineering02 engineering and technology01 natural sciencesTranslational Research BiomedicalRobotic Surgical ProceduresmedicineAnimalsMinimally Invasive Surgical ProceduresMedical physics010401 analytical chemistryRobotic Surgical ProceduresEquipment DesignProstheses and ImplantsGeneral Medicineequipment and supplies020601 biomedical engineering0104 chemical sciencesGastrointestinal TractPrinting Three-DimensionalPlasticsClinical evaluationJournal of Medical Engineering & Technology
researchProduct

Indications and contraindications of dental implants in medically compromised patients: update.

2013

The aim of this study was to review the current scientific literature in order to analyse the indications and contraindications of dental implants in medically compromised patients. A reference research was carried out on PubMed using the key words “implant” AND (oral OR dental) AND (systemic disease OR medically compromised), in articles published between 1993 and 2013. The inclusion criteria were the following: clinical studies in which, at least, 10 patients were treated, consensus articles, reviewed articles and meta-analysis performed in humans treated with dental implants, and which included the disease diagnosis. A total of 64 articles were found, from which 16 met the inclusion crit…

medicine.medical_specialtySystemic diseaseOsteoporosisMEDLINEOdontologíaDiseaseReviewRisk FactorsmedicineEndocrine systemHumansDiseaseGeneral DentistryContraindicationDental Implantsbusiness.industryContraindications:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseMedically compromised patients in DentistryCiencias de la saludSurgerystomatognathic diseasesOtorhinolaryngologyConcomitantUNESCO::CIENCIAS MÉDICASSurgeryImplantbusinessMedicina oral, patologia oral y cirugia bucal
researchProduct

Three-Year Results of Hydrus Microstent with Phacoemulsification

2019

Abstract We report the 3-year IOP efficacy of the implantation of the Schlemm’s canal Hydrus® Microstent (Ivantis®) combined with phacoemulsification versus phacoemulsification alone

medicine.medical_specialtyTime Factorsgenetic structuresmedicine.medical_treatmentGlaucoma01 natural sciencesCataract03 medical and health sciences0302 clinical medicineOphthalmologymedicineHumansSingle-Blind MethodProspective Studies0101 mathematicsGlaucoma Drainage ImplantsMiniaturizationPhacoemulsificationbusiness.industry010102 general mathematicsGlaucomaGeneral MedicinePhacoemulsificationmedicine.diseaseeye diseasesTreatment Outcome030221 ophthalmology & optometryStentssense organsbusinessFollow-Up Studies
researchProduct

Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces: in vitro study

2015

Background: Surface treatment by argon plasma is widely used as the last step of the manufacturing process of ti- tanium implant fixtures before their sterilization by gamma rays. The possibility of using such a technology in the daily clinical practice is particularly fascinating. The aim of the present study was to assess the effects of the argon plasma treatment on different titanium implant surfaces previously exposed in vitro to bacterial contamination. Material and Methods: Sterile c.p. titanium implant discs with turned (T, Sa: 0.8μm), sandblasted/acid-etched (SAE, Sa: 1.3μm) and titanium plasma sprayed (TPS, Sa: 3.0μm) surface were used in this study. A strain of Ag- gregatibacter a…

medicine.medical_specialtyTitanium implantMaterials sciencePlasma GasesSurface Propertieschemistry.chemical_elementPlasma treatmentOdontología02 engineering and technologyAggregatibacter actinomycetemcomitans03 medical and health sciences0302 clinical medicineArgon plasma titanium implant surface Aggregatibacter actinomycetemcomitans.Aggregatibacter actinomycetemcomitanmedicineIn vitro studyArgonGeneral DentistryDecontaminationDental ImplantsTitaniumColony-forming unitArgonBacteriaResearchRadiochemistrySterilization030206 dentistrySterilization (microbiology)Contamination:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyCiencias de la saludSurgeryArgon plasmaOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASEquipment ContaminationSurgeryOral SurgeryTitanium implant surface0210 nano-technologyTitanium
researchProduct

Antiproliferative Potential of African Medicinal Plants

2013

Increasingly, cancer is recognized as a critical public health problem in Africa. Medicinal plants constitute a good alternative treatment, considering the rich biodiversity of the continent. Scientific evidence of the antiproliferative activity of African medicinal plants is more and more common. The most prominent results reported include the cytotoxic effects of plants of the families Moraceae, Guttiferae, Fabaceae, as well as compounds of the groups of terpenoids and phenolics derived from African plants.

medicine.medical_specialtyTraditional medicinebiologyPublic healthfungiBiodiversitymedicinefood and beveragesFabaceaeMoraceaebiology.organism_classificationMedicinal plantsAlternative treatment
researchProduct

Medicinal Plants and DNA Methylation of Cancer

2015

Dawood M1, 2 and Efferth T1* 1Department of Pharmaceutical Biology, Institute of Pharmacy and Biochemistry, Johannes Gutenberg University, Staudinger Weg 5, 55128 Mainz, Germany 2Department of Molecular Biology, Faculty of Medical Laboratory Sciences, Al Neelain University, Aljamhoria Street, Khartoum, Sudan *Corresponding Author: Efferth T, Department of Pharmaceutical Biology, Institute of Pharmacy and Biochemistry, Johannes Gutenberg University, Staudinger Weg 5, 55128 Mainz, Germany, Tel: +49-6131-3925751; Fax: +49-6131-23752; E-mail: efferth@uni-mainz.de Received date: Oct 01, 2015, Accepted date: Oct 05, 2015, Published date: Oct 07, 2015

medicine.medical_specialtyTraditional medicinebusiness.industryFamily medicineDNA methylationMedical laboratorymedicineCancerPharmacyBiologybusinessMedicinal plantsmedicine.diseaseMedicinal & Aromatic Plants
researchProduct

Quality Control for Medicinal Plants

2012

The scientific basis of evidence-based medicine is still poor in herbal medicine. For the integration of herbal medicine into western medicine, internationally accepted standards are necessitated, including quality control of herbal products as well as preclinical and clinical evidence of safety and efficacy. In recent years, thriving innovative technologies emerged in phytotherapy research, e.g. DNA-based technologies for the authentication of plant species, good practice guidelines for standardized experimentations. High-quality herbal materials should undergo rigorous examination by analytical techniques for chemoprofiling of medicinal herbs, as well as toxicological methods to detect co…

medicine.medical_specialtyTraditional medicinebusiness.industrymedia_common.quotation_subjectAlternative medicinecomplex mixturesAuthentication (law)law.inventionClinical triallawThrivingmedicineMedicinal herbsQuality (business)Medicinal plantsPhytotherapybusinessmedia_commonMedicinal & Aromatic Plants
researchProduct

Intravitreal dexamethasone implant for cystoid macular edema and inflammation after scleral buckling

2015

Purpose Cystoid macular edema may occur following scleral buckling and therefore deteriorate the visual outcome. Inflammation may be the major causative factor in the development of postoperative cystoid macular edema. This case demonstrates the effectiveness of a dexamethasone implant as a treatment after the onset of choroidal inflammation and cystoid macular edema 6 months following scleral buckling and having visual acuity restored. Methods A 59-year-old phakic woman treated with scleral buckling for macula-off retinal detachment presented 2 months after surgery with cystoid macular edema with choroidal inflammation. Optical coherence tomography and fluorescein angiography were performe…

medicine.medical_specialtyTriamcinolone acetonideVisual acuityChoroiditisgenetic structuresVisual AcuityTriamcinolone AcetonideDrug ImplantDexamethasoneMacular EdemaChoroiditiPostoperative ComplicationsGlucocorticoidOptical coherence tomographyOphthalmologyChoroidal inflammationMedicineHumansFluorescein AngiographyMacular edemaGlucocorticoidsDexamethasoneDrug Implantsmedicine.diagnostic_testbusiness.industryIntravitreal InjectionRetinal DetachmentRetinal detachmentGeneral MedicineIntravitreal dexamethasone implantMiddle Agedmedicine.diseaseFluorescein angiographyeye diseasesOphthalmologyScleral BucklingIntravitreal InjectionsFemalesense organsImplantPostoperative Complicationmedicine.symptombusinessCystoid macular edemaTomography Optical Coherencemedicine.drugHuman
researchProduct

Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…

2017

Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…

medicine.medical_specialtyWilcoxon signed-rank testImage qualityComputed Tomography Angiographymedicine.medical_treatmentContrast MediaMagnetic resonance angiography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmMcNemar's testmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesComputed tomography angiographyRetrospective Studiesmedicine.diagnostic_testbusiness.industryIntracranial AneurysmGeneral MedicineClipping (medicine)Prostheses and Implantsmedicine.diseaseImage EnhancementSurgical InstrumentsCerebral AngiographyMetalscardiovascular systemStentsImplantRadiologybusinessArtifacts030217 neurology & neurosurgeryMagnetic Resonance AngiographyFollow-Up StudiesClinical radiology
researchProduct

Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants.

1997

In the present multi-center study. non-submerged ITI implants were prospectively followed to evaluate their long-term prognosis in fully and partially edentulous patients. In a total of 1003 patients, 2359 implants were consecutively inserted. Following a healing period of 3–6 months, the successfully integrated implants were restored with 393 removable and 758 fixed restorations. Subsequently, all consecutive implants were documented annually up to 8 years. At each examination, the clinical status of all implants was evaluated according to predefined criteria of success. Therefore, the data base allowed the evaluation of 8-year cumulative survival and success rates for 2359 implants. In ad…

medicine.medical_specialtybusiness.industryDentistryNon submergedOsseointegrationSurgeryLife tableMulti center studyDrop outmedicineImplantOral SurgerybusinessEarly failureIti implantsClinical Oral Implants Research
researchProduct