Search results for "PLIF"
showing 10 items of 835 documents
Low-noise microvolt level calibrator for measurement of performance of biosignal recording systems
1997
A calibrator, the noise level of which is below the noise level generated in the preamplifier system, was needed for testing and development of a multichannel recording system. A multichannel preamplifier head assembly was used for recording cortical, subcortical, and cerebellar slow potentials and multiunit activity in freely moving cats and restrained rabbits. An inexpensive, battery-powered, lownoise voltage signal generator for calibration of the preamplifiers is described. The circuit provides a square-wave output at a frequency of 10 or 1000 Hz, and the peak-to-peak (p-p) amplitude can be selected at 10, 100, or 1000µV. The measured output noise of the calibrator is below 2µV (p-p, 0.…
Photonically assisted RF generator with incoherent sources
2008
An RF waveform generator operating with incoherent broadband light is successfully implemented. Complex RF ~10 GHz bandwidth waveforms are generated by means of incoherent wavelength-to-time mapping. Our technique can be scaled to the mm-wave range.
Reconfigurable RF waveform generation using optical incoherent sources
2008
An RF waveform generator operating with incoherent broadband light is successfully implemented. Complex RF ~10 GHz bandwidth waveforms are generated by means of incoherent wavelength-to-time mapping. Our technique can be scaled to the mm-wave range.
Towards high photon-number soft x-ray lasers
2011
We present an experimental design to independently pump two soft X-ray laser media suitable for a seed-amplifier configuration. Both the seed and the amplifier target are operated in the TCE scheme utilizing the DGRIP technique with its intrinsic travelling wave excitation. Controlled injection of the seed X-ray laser into the amplifier medium is realized via a spherical XUV mirror. The experimental design is perfectly appropriate for benchmarking combined simulations of the ARWEN and DeepOne code. A first experiment at the PHELIX laser utilizing this scheme has been conducted, demonstrating signs of amplification and allowing for the direct measurement of the gain life time of a Ni-like si…
Optimization of soliton transmissions in dispersion-managed fiber links
1998
We propose a simple optimization criterion (including the best launch point position in-between amplifiers) for the design of soliton transmission lines. The present approach is shown to minimize energy scattering from the solitons into the continuum.
A ten-fold divided total absorption Ge(Li) gamma-ray detector
1976
Abstract We have constructed a split-crystal total absorption Ge(Li) gamma-ray spectrometer and special logic electronics for rejecting Compton continuum in spectra. A 10 cm3 planar detector was divided into ten electrically separated detectors by grinding nine parallel slots on the n-surface of the detector. In operation both the n- and p-contacts are isolated from the ground. Using capacitive sharing, most of the released electrical charge is taken from the p-contact into an ordinary pulse amplifier line and analyzed. A small fraction of the charge collected at the n-strips is observed with voltage-sensitive FET-preamplifiers. The following logic electronics provides a gate pulse for the …
Optical Harmonic Generation Parametric Devices
1999
The sections in this article are 1 Nonlinear Optics: an Actual and Wide Field Of Optics Research 2 Main Applications of Parametric Devices 3 Induced Macroscopic Polarization 4 Electromagnetic Energy Exchange 5 Nonlinear Materials 6 Propagation of the Waves in the Nonlinear Medium 7 Second Harmonic Generation 8 Optical Parametric Generators and Amplifiers 9 Optical Parametric Oscillators 10 Recent Advances in Frequency Conversion
Sub-kelvin current amplifier using DC-SQUID
2000
Abstract We have set up a system where a low-noise DC-SQUID is used as a current amplifier. The SQUID output is read using a wide band electronics unit based on the noise cancellation scheme. The SQUID has been installed in a compact Nanoway PDR50 dilution refrigerator, and superconducting transitions of Ti/Au thermometer strips for X-ray calorimeter applications have been measured. We can operate at 100 mK using a SQUID with Pd shunt resistors. Noise and bandwidth results of the setup are presented.
Multimode squeezing of frequency combs
2006
We have developed a full multimode theory of a synchronously pumped type-I optical parametric oscillator. We calculate the output quantum fluctuations of the device and find that, in the degenerate case (coincident signal and idler set of frequencies), significant squeezing is obtained when one approaches threshold from below for a set of well-defined ``supermodes,'' or frequency combs, consisting of a coherent linear superposition of signal modes of different frequencies which are resonant in the cavity.
Stability of gyrotron operation in very high-order modes
2012
This study was motivated by the desire to increase the power, which can be delivered by gyrotrons in long pulse and continuous regimes. Since the admissible power level is determined by the density of ohmic losses in resonator walls, to increase the radiated power a gyrotron should operate in higher order modes. Using an existing gyrotron developed for plasma experiments in the International Thermonuclear Experimental Reactor as a base model, the stability of operation of such a gyrotron in modes with larger number of radial variations was studied. It is shown that the power level achievable in such gyrotrons in stable single mode regimes is close to 1.5 MW. The power level 1.7–1.8 MW can b…