Search results for "PRESSURE"

showing 10 items of 4493 documents

Towards understanding the complexity of cardiovascular oscillations: Insights from information theory.

2018

Abstract Cardiovascular complexity is a feature of healthy physiological regulation, which stems from the simultaneous activity of several cardiovascular reflexes and other non-reflex physiological mechanisms. It is manifested in the rich dynamics characterizing the spontaneous heart rate and blood pressure variability (HRV and BPV). The present study faces the challenge of disclosing the origin of short-term HRV and BPV from the statistical perspective offered by information theory. To dissect the physiological mechanisms giving rise to cardiovascular complexity in different conditions, measures of predictive information, information storage, information transfer and information modificati…

Blood pressure variabilityAdultMalemedicine.medical_specialtySupine positionAdolescent0206 medical engineeringInformation TheoryHealth InformaticsBlood Pressure02 engineering and technologyBaroreflexCardiovascular Physiological Phenomena03 medical and health sciencesElectrocardiographyYoung AdultRedundancy0302 clinical medicineHeart RateInternal medicineHeart ratemedicineHeart rate variabilityHumansVagal toneHeart rate variabilitybusiness.industryModels CardiovascularCardiorespiratory fitnessSignal Processing Computer-AssistedComplexity020601 biomedical engineeringComputer Science ApplicationsCausalityBlood pressureSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyFemalebusiness030217 neurology & neurosurgeryRespiratory minute volumeComputers in biology and medicine
researchProduct

RELATIONSHIPS BETWEEN SHORT-TERM BLOOD PRESSURE VARIABILITY AND EARLY RENAL DYSFUNCTION IN ESSENTIAL HYPERTENSIVE PATIENTS

2014

Blood pressure variabilityBlood pressure variability; Ambulatory Blood pressure monitoring; renal damage; arterial hypertensionAmbulatory Blood pressure monitoringarterial hypertensionrenal damage
researchProduct

RELATIONSHIPS BETWEEN SHORT-TERM BLOOD PRESSURE VARIABILITY AND EARLY RENAL DYSFUNCTION IN HYPERTENSION

2014

The prognostic significance of short–term blood pressure (BP) variability (STBPV), expressed as standard deviation (SD) of blood pressures (BP) intermittently recorded over 24 hours, is debated. Recently, indices of STBPV other than SD have been proposed. Among these, the 24-h BP Average Real Variability (ARV) seems to be associated more consistently than SD with an enhanced cardiovascular risk. The relationship between mild-to-moderate renal dysfunction (MMRD) and ARV was not investigated. Our study was aimed to analyse, in a large group of untreated essential hypertensives, the relationships between ARV, and other STBV indices, with MMRD. We enrolled 329 essential hypertensive patients, w…

Blood pressure variabilityHypertensionrenal dysfunction.
researchProduct

Should reduction of increased short‐term blood pressure variability be a target of antihypertensive therapy?

2021

Abstract It has long been known that blood pressure (BP) is characterized by marked short‐term fluctuations occurring within a 24‐h period and also by long‐term oscillations occurring over more prolonged periods of time. An increased short‐term blood pressure variability (BPV) appears to importantly contribute to target organ damage and to the enhanced cardiovascular risk of hypertensive patients, over and above the effect of an increase in mean BP levels. Reducing 24‐h mean BP is the main aim of antihypertensive therapy, but initial data are available that additional cardiovascular protection can be achieved by reducing BPV. However, to definitively prove the prognostic role of short‐term …

Blood pressure variabilityIntervention trialsmedicine.medical_specialtyAmbulatory blood pressureEndocrinology Diabetes and MetabolismBlood Pressure030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineInternal medicineInternal MedicineHypertension generalHumansMedicine030212 general & internal medicineAntihypertensive Agentsbusiness.industryLeft ventricular hypertrophy (LVH) hypertensionBlood Pressure DeterminationAmbulatory blood pressureBlood Pressure Monitoring Ambulatoryhypertension—generalTarget organ damageOrgan damageAntihypertensive AgentBlood pressureHypertensionCommentaryCardiologyCardiology and Cardiovascular MedicinebusinessHumanThe Journal of Clinical Hypertension
researchProduct

ABSENCE OF RELATIONSHIPS BETWEEN SHORT-TERM BLOOD PRESSURE VARIABILITY AND EARLY RENAL DYSFUNCTION IN HYPERTENSION

2014

Blood pressure variability

Blood pressure variabilityambulatory blood pressure monitoring arterial hypertension.renal disease
researchProduct

Blood pressure and glycaemia, not insulin-resistance, influence endothelial dysfunction in metabolic syndrome

2005

Blood pressure endothelial dysfunction metabolic syndrome
researchProduct

Role of Trained Nurses in the Blood Pressure Control of Treated Essential Hypertensive Patients

2007

Blood pressureAmbulatory blood pressurePharmacotherapybusiness.industryAnesthesiaInternal MedicinePhysical activityMedicineCardiology and Cardiovascular MedicinebusinessHigh Blood Pressure & Cardiovascular Prevention
researchProduct

Photoplethysmography system for blood pulsation detection in unloaded artery conditions

2012

Photoplethysmography (PPG) is an optical method of blood pulsation recording and has been extensively studied for decades. Recently PPG is widely used in the medical equipment for patient monitoring and in laboratories for research and physiological studies. In spite of the technological progress in the field of medical equipment, there are no generally accepted standards for clinical PPG measurements up to date. One of the most important factors affecting PPG waveform is the contact pressure between tissue and PPG probe. The aim of the current study was to develop and evaluate a system for software-assisted PPG signal acquisition from the unloaded artery. Novel PPG waveform derived Optimal…

Blood pressureTransmural pressuremedicine.anatomical_structureComputer scienceRemote patient monitoringPhotoplethysmogrammedicinePlethysmographWaveformsense organsArteryBiomedical engineeringSPIE Proceedings
researchProduct

Pharmacokinetics of acute and sub-chronic aripiprazole in P-glycoprotein deficient mice

2010

Abstract Background P-glycoprotein (P-gp), an efflux transporter localized in the blood–brain barrier, limits the access of multiple xenobiotics to the central nervous system (CNS). For the new antipsychotic aripiprazole and its active metabolite dehydroaripiprazole differences in disposition in blood and brain were investigated after acute and sub-chronic administration in a P-gp knockout mouse model. Methods Serum and brain concentrations of both drugs were measured at several time points 1–24 h after i.p. injection of 10 mg/kg aripiprazole and after 11 days of sub-chronic administration in several tissues. Moreover, the expression of P-gp was determined by Western blot analysis after sub…

Blotting WesternCentral nervous systemAripiprazoleQuinolonesPharmacologyBlood–brain barrierMass SpectrometryPiperazinesMiceCellular and Molecular NeurosciencePharmacokineticsmedicineAnimalsATP Binding Cassette Transporter Subfamily B Member 1Chromatography High Pressure LiquidActive metaboliteP-glycoproteinMice KnockoutPharmacologyAnalysis of VariancebiologyChemistryBrainBiological TransportTransportermedicine.anatomical_structureBlood-Brain BarrierKnockout mousebiology.proteinAripiprazoleAntipsychotic Agentsmedicine.drugNeuropharmacology
researchProduct

In-vitro test system for the evaluation of cyclooxygenase-1 (COX-1) and cyclooxygenase-2 (COX-2) inhibitors based on a single HPLC run with UV detect…

2001

Objective and Design: The aim of this study was to develop a new, whole-cell test system which is easy to handle and requires a standard equipment for the parallel screening of COX-1 and COX-2 inhibitors.¶Materials: Bovine aortic endothelial cells (BAECs).¶Treatment and methods: Unstimulated bovine aortic coronary endothelial cells (BAECs) were used as a source of COX-1 and BAECs pretreated with ASA (100 μM) and activated with phorbol myristate acetate (PMA) were used as a source of COX-2. The time- and concentration-dependent induction of COX-2 expression in the BAECs was evaluated by a kinetic profile (HPLC analysis) and detected by Western-Blot analysis using polyclonal antibodies agains…

Blotting WesternImmunologyDrug Evaluation PreclinicalAorta ThoracicIn Vitro TechniquesHigh-performance liquid chromatographyLipoxygenaseDiclofenacmedicineAnimalsCyclooxygenase InhibitorsLipoxygenase InhibitorsIC50Chromatography High Pressure LiquidPharmacologyCyclooxygenase 2 InhibitorsbiologyChemistryMolecular biologyIsoenzymesKineticsMeloxicamBiochemistryCyclooxygenase 2Prostaglandin-Endoperoxide SynthasesPolyclonal antibodiesCyclooxygenase 1biology.proteinTetradecanoylphorbol AcetateAceclofenacCattleSpectrophotometry UltravioletEndothelium VascularCyclooxygenasemedicine.drugInflammation Research
researchProduct