Search results for "PROTECTION"

showing 10 items of 1623 documents

National guidelines for dental diagnostic imaging in the developmental age

2019

This document aims to support the dental professional in choosing the adequate diagnostic technique, minimising the radiation dose in observance of the As Low As Reasonably Achievable (ALARA) principle (7). This principle states that the biological cost can only be justifed when the beneft, that is, the diagnosis, outweighs the risk related to radiation exposure. In this guideline paper, we report recommendations for radiologists, medical physicists, paediatrician, dentists and maxillofacial surgeons, with reference to the specifc felds.

medicine.medical_specialtyRadiology Nuclear Medicine and ImagingRadiographydentalMEDLINEdental care for childrenDental diagnostic imagingRadiography DentalMedicineMedical physicshumansDental ProcedureNeuroradiologychildmedicine.diagnostic_testDevelopmental agebusiness.industryDental Care for ChildrenInterventional radiologyGeneral Medicineadolescent; child; dental care for children; humans; Italy; radiation protection; radiography dentalItalyadolescentbusinessradiation protectionradiography
researchProduct

Editorial from guest editors current Euratom legislation (DE 59/2013): new patient management in radiation protection.

2019

none

medicine.medical_specialtySafety ManagementLegislationHealth PhysicRadiation ProtectionRadiation MonitoringmedicineHumansRadiology Nuclear Medicine and imagingMedical physicsEuropean UnionRadiation InjurieRadiation InjuriesNeuroradiologymedicine.diagnostic_testbusiness.industryRadiation doseRadiation doseInterventional radiologyGeneral MedicineRadiation ExposurePatient managementRadiation protectionCurrent (fluid)businessEuratom legislationHealth PhysicsHumanLa Radiologia medica
researchProduct

Ten physiological commandments for severe head injury

2020

Advances in multiparametric brain monitoring have allowed us to deepen our knowledge of the physiopathology of head injury and how it can be treated using the therapies available today. It is essential to understand and interpret a series of basic physiological and physiopathological principles that, on the one hand, provide an adequate metabolic environment to prevent worsening of the primary brain injury and favour its recovery, and on the other hand, allow therapeutic resources to be individually adapted to the specific needs of the patient. Based on these notions, this article presents a decalogue of the physiological objectives to be achieved in brain injury, together with a series of …

medicine.medical_specialtySevere head injuryIntracranial Pressurebusiness.industryHead injuryArterial oxygenBrainCerebral hypoxia030208 emergency & critical care medicineGeneral MedicineBrain monitoringmedicine.diseaseNeuroprotectionAbdominal pressureOxygen03 medical and health sciences0302 clinical medicineBrain InjuriesmedicineHumansHypoxia BrainIntensive care medicinebusiness030217 neurology & neurosurgeryIntracranial pressureRevista Española de Anestesiología y Reanimación (English Edition)
researchProduct

A new resonant Laser-SNMS system for environmental ultra-trace analysis: Installation and optimization

2017

Abstract Localization, analysis and mobility of radioactive contaminated particles is of major concern for assessment of contamination threads and nuclear forensics. For this purpose, a new resonant Laser-SNMS system was developed and set up at the Institute for Radioecology and Radiation Protection for spatially resolved ultra-trace analysis of low concentrated radionuclides directly on environmental samples. This paper describes the adaption and combination of a dedicated Ti:sapphire laser system with a commercial TOF-SIMS instrument for resonant Laser-SNMS. The project includes computer simulations for optimization of the TOF analyzer. Results on synthetic uranium and technetium samples …

medicine.medical_specialtySpectrum analyzerNuclear forensicsNuclear engineeringchemistry.chemical_elementNanotechnology01 natural scienceslaw.inventionRadioecologylaw0103 physical sciencesmedicinePhysical and Theoretical Chemistry010306 general physicsInstrumentationSpectroscopyRadionuclideChemistrybusiness.industry010401 analytical chemistryUraniumContaminationCondensed Matter PhysicsLaser0104 chemical sciencesRadiation protectionbusinessInternational Journal of Mass Spectrometry
researchProduct

Erythropoietin and the heart: physiological effects and the therapeutic perspective.

2014

Erythropoietin (Epo) has been thought to act exclusively on erythroid progenitor cells. The identification of Epo receptor (EpoR) in non-haematopoietic cells and tissues including neurons, astrocytes, microglia, immune cells, cancer cell lines, endothelial cells, bone marrow stromal cells, as well as cells of myocardium, reproductive system, gastrointestinal tract, kidney, pancreas and skeletal muscle indicates that Epo has pleiotropic actions. Epo shows signals through protein kinases, anti-apoptotic proteins and transcription factors. In light of interest of administering recombinant human erythropoietin (rhEpo) and its analogues for limiting infarct size and left ventricular (LV) remodel…

medicine.medical_specialtyStromal cellCardiotonic AgentsAngiogenesisNeovascularization PhysiologicInflammationerythroid progenitor cellshemic and lymphatic diseasesInternal medicineEpo receptorReceptors ErythropoietinMedicineHumansErythropoietinCardioprotectionMicrogliabusiness.industryHeartErythropoietin receptorErythropoietin; Epo receptor; erythroid progenitor cellsEndocrinologymedicine.anatomical_structureErythropoietinCancer researchAirway RemodelingBone marrowmedicine.symptomCardiology and Cardiovascular Medicinebusinessmedicine.drugInternational journal of cardiology
researchProduct

Erythropoietin for Subarachnoid Hemorrhage: Is There a Reason for Hope?

2011

I b S a r a S ubarachnoid hemorrhage (SAH) associated with a ruptured cerebral aneurysm remains a source of significant morbidity and mortality, not only from the initial hemorrhage but lso from the delayed complications, such as cerebral vasospasm ften severe enough to induce irreversible changes in cerebral erfusion. Several drugs have been developed that have the otential to limit cerebral vasospasm and delayed ischemic eurologic deficit, thus improving outcome for patients. Howver, although numerous agents that can prevent arterial narrowng and/or block the excitatory cascade of events leading to schemic neuronal death in experimental conditions, there is still o pharmacologic agent tha…

medicine.medical_specialtySubarachnoid hemorrhageErythropoietin subarachnoid hemorrhageBlood volumeAneurysm RupturedNeuroprotectionAneurysmCerebral vasospasmInternal medicinemedicineErythropoietin; Neuroprotection; Subarachnoid hemorrhageHumansSubarachnoid hemorrhageErythropoietinSettore MED/27 - Neurochirurgiabusiness.industryEpoetin alfaPharmacologic Agentmedicine.diseaseRecombinant ProteinsNeuroprotectionEpoetin AlfaNeuroprotective AgentsErythropoietinCardiologySurgeryNeurology (clinical)businessmedicine.drug
researchProduct

Imaging funzionale per diffusione (DWI) e ischemia cerebrale in fase acuta: Potenzialità diagnostiche e confronto con metodiche convenzionali

1997

Stroke is the third leading cause of death and is a major cause of long-term disability. Neuroprotective treatment within a 4-hour «therapeutic window» has proved highly efficacious in reducing morbility and mortality in animal model. It is with this background that the need for emergent diagnosis and therapy of acute stroke in strongly suggested. Computed tomography (CT) shows the parenchymal changes of acute stroke too late to be helpful, and its role has been primarily to evaluate the possibility of intracerebral or subarachnoid hemorrhage. While conventional magnetic resonance (MR) imaging can demonstrate parenchymal abnormalities 4–6 hours after ischemia, newer techniques such as diff…

medicine.medical_specialtySubarachnoid hemorrhageRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryIschemiaInfarctionMagnetic resonance imagingmedicine.diseaseNeuroprotection030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAnimal modelmedicineRadiology Nuclear Medicine and imagingcardiovascular diseasesNeurology (clinical)RadiologybusinessStroke030217 neurology & neurosurgeryCause of deathRivista di Neuroradiologia
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Metabolic adaptation and neuroprotection differ in the retina and choroid in a piglet model of acute postnatal hypoxia.

2013

Hypoxic-ischemic insults to the neonatal brain may cause neurodevelopmental disorders. Vulnerability of different areas of the neural tissue to hypoxic-ischemic stress might be explained by either heterogeneous sensitivity to oxygen or neuroprotective capability. Our understanding of regional heterogeneity is still incomplete in terms of metabolic reconfiguration and/or activation of neuroprotective mechanisms.We studied, by western blotting, reverse-transcriptase PCR, and tandem mass spectrometry, the response of retina and choroid at protein, gene, and metabolic levels during hypoxia in a piglet model of acute postnatal hypoxia.We evidenced a metabolic shift towards glycolysis in choroid …

medicine.medical_specialtySwineanimal diseasesBlotting WesternMetabolic adaptationNeuroprotectionRetinafluids and secretionsStress PhysiologicalTandem Mass SpectrometryInternal medicinemedicineAnimalsHypoxiaRetinaintegumentary systembusiness.industryChoroidReverse Transcriptase Polymerase Chain ReactionHypoxia (medical)Hypoxia-Inducible Factor 1 alpha Subuniteye diseasesBlotmedicine.anatomical_structureEndocrinologyAnimals NewbornAnesthesiaPediatrics Perinatology and Child Healthsense organsChoroidmedicine.symptombusinessEnergy MetabolismGlycolysisSignal TransductionPediatric research
researchProduct

Radiation exposure in vascular angiographic procedures.

2012

Abstract Purpose To evaluate dose reduction in vascular angiographic procedures by using fluoroscopy capture instead of digital subtraction angiography frames for documentation. Materials and Methods A total of 764 consecutive vascular interventional procedures performed over a period of 1 year were retrospectively analyzed with respect to the fluoroscopy time and the resulting dose–area product (DAP), the DAP of the radiographic frames, and the overall DAP. Results A total of 70% of the total DAP was a result of the acquisition of radiographic frames, leaving only 30% being applied by fluoroscopy. Conclusions Fluoroscopy capture should be used for documentation whenever possible. A registr…

medicine.medical_specialtyTime FactorsRadiographyHealth PersonnelRadiation DosageRadiography InterventionalRadiation ProtectionRadiation MonitoringOccupational ExposuremedicineFluoroscopyHumansRadiology Nuclear Medicine and imagingOccupational HealthRetrospective Studiesmedicine.diagnostic_testbusiness.industryAngiography Digital SubtractionDigital subtraction angiographyRadiation exposureDose area productFluoroscopyDose reductionRadiologyCardiology and Cardiovascular MedicinebusinessNuclear medicineJournal of vascular and interventional radiology : JVIR
researchProduct