Search results for "Palmitic Acids"
showing 3 items of 13 documents
Temperature and pressure dependence of quercetin-3-O-palmitate interaction with a model phospholipid membrane: film balance and scanning probe micros…
2004
The molecular interaction of quercetin-3-O-palmitate (QP) with dimyristoylphosphatidylcholine (DMPC) has been studied. Film balance measurements of the average molecular area vs QP molar fraction in DMPC/QP mixed monolayers showed that relevant positive deviations from ideality, i.e., a less dense monolayer packing, occurred for a temperature of 10 degrees C, below the critical melting transition temperature of DMPC monolayers T c m approximately equal 20 degrees C), while ideal behavior was observed at 37 degrees C, above this phase transition temperature. The positive deviation observed at low temperatures in the average molecular area increased with the surface pressure. Scanning probe m…
Control of oxidative metabolism in volume-overloaded rat hearts: effects of different lipid substrates.
1994
The relationship between intracellular energy parameters and myocardial O2 consumption (VO2) was studied in control and volume-overloaded hearts perfused with different lipid substrates and over a range of left ventricular work loads. In control hearts, a unique linear relationship between log of cytosolic [ATP]/[ADPf].[Pi] (where [ADPf] is concentration of free ADP) and myocardial VO2 was observed between low and high work loads for both fatty acids studied. In volume-overloaded hearts perfused in the presence of exogenous palmitate, the slope of the relationship between log [ATP]/[ADPf].[Pi] and myocardial VO2 was considerably depressed. It would seem that, under these conditions, much o…
Analysis of radiolucent gallstones by computed tomography for in vivo estimation of stone components.
1990
. Successful oral litholytic and other non-operative therapies of gallstones require exact determination of the stone components. Since computed tomography (CT) provides highly sensitive measurement of density, we performed a study to evaluate whether CT measurement of stone density allows a prediction of the composition of radiolucent gallstones. Twenty-eight patients presenting with 29 radiolucent gallbladder (n= 17) or common bile duct stones (n=12) were included. Prior to operative or endo-scopic therapy the attenuation values (Hounsfield Units, HU) were assessed in vivo by CT under standardized conditions (Somatom II, 125 KV, 130 mAs). After surgical or endoscopic stone removal the con…