Search results for "Partial discharge"
showing 10 items of 70 documents
Radiometric Partial Discharge Detection: A Review
2023
One of the most common failures or breakdowns that can occur in high-voltage (HV) equipment is due to partial discharges (PDs). This occurs as a result of inadequate insulation, aging, harsh environmental effects, or manufacturing flaws. PD detection and recognition methods have gained growing attention and have seen great progress in the past decades. Radiometric methods are one of the most investigated detection approaches due to their immunity to electromagnetic interference (EMI) and their capabilities to detect and locate PD activities in different applications such as transformers, cables, etc. Several review articles have been published to classify and categorize these works. Nonethe…
Simplified Hybrid PD Model in Voids
2011
In this paper a novel approach to model partial discharges (PD) activity taking place inside a spherical void in epoxy resin system has been traced. The approach is based on a time varying conductance of the inner void, subjected to multistress conditions: voltage, temperature and pressure. A simple lumped circuit macro-model simulates the global effects of PD activity: the different parameters influencing the discharge phenomenon in the void are taking into account by using a physical approach resulting in a time varying conductance inside the circuit. The evaluated PD activity has been compared with experimental and simulated one for the accessible and inaccessible part of the system. A d…
Simplified hybrid PD model in voids: Pattern validation
2013
The purpose of the present work is to show the validation of a new model to simulate the physical phenomenon of partial discharge (PD) produced in air voids inside insulating epoxy resin. The model has been developed on the basis of a new approach that combines the known circuit model of three capacitors with a model used to describe the behavior of the ionized channel inside of the inclusion during the discharge phenomenon, short-circuiting the capacity that represents the void. The approach is based on time-variable conductance of the void, subjected to multistress conditions: voltage, temperature and pressure. The new approach has been developed from a time variable conductivity model us…
A Novel Histogram for Partial Discharge Signals in HV Insulating Systems
1986
A technique for relating measurable electrical quantities with energies dissipated inside a void in highly electrically stressed insulation is presented. It is based on measuring, for each apparent discharge level qe, the algebraic sum of the external energy pulses of all discharges having a value qe and occurring over some cycles of test voltage. Theoretical investigations show that the results of such external energy summations are equal to the energies dissipated in the void. A novel histogram is also suggested which relates the apparent discharge amplitudes with their respective energies in the void. Experimental tests were carried out under controlled conditions with samples of thermop…
Partial discharge tests using CIGRE method II
2000
In this paper, the results of an experimental project on insulating material aging, performed in both Denmark and Italy, are reported. This study was concerned with partial discharge (PD) behavior at temperatures between 30 and 80/spl deg/C using CIGRE method II. The material tested was a commercial polymethylmethacrylate (PMMA) which was chosen not for its good dielectric properties but rather because much of its discharge resistance data at ambient temperature is already well documented. A description is given of the theoretical and experimental methodology followed in this work. Mixed Weibull analysis techniques in terms of the PD amplitude and phase distribution characteristics were emp…
PD recognition by means of statistical and fractal parameters and a neural network
2000
A novel partial discharge (PD) defect identification method is described. Starting with PD data on different families of specimens, a suitable set of parameters are determined and then used as input variables to a neural network for the purpose of identifying the defects within the insulation. In this procedure the statistical Weibull analysis is performed on PD pulse amplitude histograms to obtain the scale parameter /spl alpha/ and the shape parameter /spl beta/. Thereafter, the two statistical operators (skewness and kurtosis) and two fractal parameters (fractal dimension and lacunarity) are evaluated from the PD phase on the discharge epoch histogram and from the 3 dimensional (pulse am…
Partial Discharge Tests Using CIGRE Method II Upon Nanocomposite Epoxy Resins
2007
Nanocomposite polymers are becoming a new family of dielectric materials with promising insulating properties. In order to apply this technology to insulation systems, a study about the material longterm endurance (life) is needed. In this paper results from comparative life tests performed upon base and nanostructured epoxy resin samples are presented. The nanofiller is a organophillic-modified ultra-clean montmorillonite. Specimens were subjected to ageing under surface discharge phenomena using a standard electrode configuration, that is the CIGRE method II. Life data and partial discharge phase resolved patterns, acquired during time under stress, are presented and commented, in order t…
PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
2022
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studi…
Pulsed Electro-Acoustic space charge apparatus – qualifying, testing and monitoring of insulation for HVDC cables and accessories
2022
Partial Discharges in HVDC Cables - The Effect of the Temperature Gradient During Load Transients
2021
The paper investigates the role of the space charge accumulation phenomena in the inception of Partial Discharges (PD) in a defect within the bulk of the dielectrics of a High Voltage Direct Current (HVDC) cable. It is widespread accepted that the number of PD occurring in an HVDC cable during its lifetime is largely less than that under AC voltage stress. This is essentially due to higher values of the voltage between the conductor and the screen needed to trigger PD under a steady DC voltage than the same value under AC stress. Nevertheless, due to the dependency of the electrical conductivity of the insulation on the electric field and temperature, PD in HVDC cables is strongly influence…