Search results for "Particle accelerator"

showing 10 items of 180 documents

Accelerating Radioactive Ion Beams With REX-ISOLDE

2003

The post accelerator REX‐ISOLDE is installed at the ISOLDE facility at CERN, where a broad variety of radioactive ions can be addressed. Since the end of 2001 beams at the final energy of 2.2 MeV/u are available. REX‐ISOLDE uses a unique system of beam bunching and charge breeding. First a Penning trap accumulates and bunches the ions, which are delivered as a quasi‐continuous beam from the ISOLDE target‐ion‐source, and then an electron beam ion source (EBIS) charge‐breeds them to a mass‐to‐charge ratio below 4.5. This enables a very compact design for the following LINAC, consisting of a 4 rod RFQ, an IH structure and three 7‐gap‐resonators. The later ones allow a variation of the final en…

Large Hadron ColliderChemistryParticle acceleratorPenning trapIon sourceLinear particle acceleratorlaw.inventionNuclear physicsBuncheslawPhysics::Accelerator PhysicsNeutronAtomic physicsNuclear ExperimentBeam (structure)AIP Conference Proceedings
researchProduct

Tensor Analyzing Powers for Quasi-Elastic Electron Scattering from Deuterium

1999

We report on a first measurement of tensor analyzing powers in quasi-elastic electron-deuteron scattering at an average three-momentum transfer of 1.7 fm$^{-1}$. Data sensitive to the spin-dependent nucleon density in the deuteron were obtained for missing momenta up to 150 MeV/$c$ with a tensor polarized $^2$H target internal to an electron storage ring. The data are well described by a calculation that includes the effects of final-state interaction, meson-exchange and isobar currents, and leading-order relativistic contributions.

MOMENTUM DISTRIBUTIONNuclear TheoryGeneral Physics and AstronomyFOS: Physical sciencesElectron01 natural scienceslaw.inventionNuclear physicslawNUCLEON CROSS-SECTIONS0103 physical sciencesTensorSTORAGE-RINGNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentPhysicsFORM-FACTORPOLARIZED ELECTRONS010308 nuclear & particles physicsScatteringParticle accelerator3. Good healthTARGETDeuteriumIsobarNEUTRONNucleonElectron scattering
researchProduct

PERIPHERAL SURFACE DOSE FROM A LINEAR ACCELERATOR: RADIOCHROMIC FILM EXPERIMENTAL MEASUREMENTS OF FLATTENING FILTER FREE VERSUS FLATTENED BEAMS

2020

Abstract There is a growing interest in the use of flattening filter free (FFF) beams due to the shorter treatment times. The reduction of head scatter suggests a better radiation protection to radiotherapy patients, considering the expected decrease in peripheral surface dose (PSD). In this work, PSD of flattened (FF) and FFF-photon beams was compared. A radiochromic film calibration method to reduce energy dependence was used. PSD was measured at distances from 2 to 50 cm to the field border for different square field sizes, modifying relevant clinical parameters. Also, clinical breast and prostate stereotactic body radiotherapy (SBRT) plans were studied. For square beams, FFF PSD is lowe…

MaleSurface (mathematics)Materials scienceRadiosurgerySquare (algebra)Linear particle accelerator030218 nuclear medicine & medical imaging03 medical and health sciencesRadiation Protection0302 clinical medicineOpticsCalibrationHumansRadiology Nuclear Medicine and imagingRadiochromic filmPhotonsRadiationFlattening filter freeRadiological and Ultrasound Technologybusiness.industryRadiotherapy Planning Computer-AssistedPublic Health Environmental and Occupational HealthRadiotherapy DosageGeneral MedicinePeripheral030220 oncology & carcinogenesisParticle AcceleratorsRadiation protectionbusinessRadiation Protection Dosimetry
researchProduct

Mass Measurements with the CSS2 and CIME cyclotrons at GANIL

2005

Commune avec ACEN; This paper presents two original direct mass-measurement techniques developed at GANIL using the CSS2 and CIME cyclotrons as high-resolution mass spectrometers. The mass measurement with the CSS2 cyclotron is based on a time-of-flight method along the spiral trajectory of the ions inside the cyclotron. The atomic mass excesses of 68Se and 80Y recently measured with this technique are -53.958(246) MeV and -60.971(180) MeV, respectively. The new mass-measurement technique with the CIME cyclotron is based on the sweep of the acceleration radio-frequency of the cyclotron. Tests with stable beams have been performed in order to study the accuracy of this new mass-measurement m…

Mass numberChemistryCyclotron020206 networking & telecommunicationsParticle accelerator02 engineering and technologyrp-process[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryAtomic masslaw.inventionIonNuclear physicsAccelerationlaw29.20.Hm 29.30.-h 21.10.Dr 27.50.+e0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processing
researchProduct

The electron cyclotron resonance ion source with arc-shaped coils concept

2012

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cos…

Materials scienceIon beamOptical PhenomenaPlasma Gasesta114Highly charged ionCyclotron resonanceTemperatureParticle acceleratorElectronsCyclotronsModels TheoreticalIon gunIon sourceElectron cyclotron resonancelaw.inventionMagnetic FieldslawAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

The laser ion source trap for highest isobaric selectivity in online exotic isotope production

2010

The improvement in the performance of a conventional laser ion source in the laser ion source and trap (LIST) project is presented, which envisages installation of a repeller electrode and a linear Paul trap/ion guide structure. This approach promises highest isobaric purity and optimum temporal and spatial control of the radioactive ion beam produced at an online isotope separator facility. The functionality of the LIST was explored at the offline test separators of University of Mainz (UMz) and ISOLDE/CERN, using the UMz solid state laser system. Ionization efficiency and selectivity as well as time structure and transversal emittance of the produced ion beam was determined. Next step aft…

Materials scienceIon beamParticle acceleratorLaserIon sourceIonlaw.inventionNuclear physicslawIonizationPhysics::Accelerator PhysicsThermal emittancePhysics::Atomic PhysicsIon trapAtomic physicsNuclear ExperimentInstrumentationReview of Scientific Instruments
researchProduct

The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS.

2010

Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount o…

Materials scienceIon beamlawRF power amplifierBremsstrahlungParticle acceleratorPlasma diagnosticsIon currentPlasmaRadio frequencyAtomic physicsInstrumentationlaw.inventionThe Review of scientific instruments
researchProduct

Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation.

2012

Linac4 accelerator of Centre Européen de Recherches Nucléaires is under construction and a RFdriven H− ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended opera…

Materials scienceNuclear engineeringchemistry.chemical_elementnegative ionsLinear particle acceleratorIonlaw.inventionion sourceslawSputteringPenning dischargesInstrumentationlinear acceleratorsplasma sourcesta114Particle acceleratorIon sourceCathodeplasma transport processesAnodechemistryparticle beam extractionMolybdenumAtomic physicssputteringmolybdeeniThe Review of scientific instruments
researchProduct

Temperature dependence of slow-positron production and of positronium formation on untreated surfaces

1987

Low-energy positron emission from tungsten moderators, placed at a electron accelerator beam stop slows down with increasing moderator temperature. Efficient positronium formation is reported on untreated and unoriented metal surfaces at higher target temperatures.

Materials sciencePhysics and Astronomy (miscellaneous)General Engineeringchemistry.chemical_elementParticle acceleratorGeneral ChemistryTungstenMathematics::Geometric Topologylaw.inventionPositroniumMetalPositronchemistrylawvisual_artvisual_art.visual_art_mediumPhysics::Accelerator PhysicsGeneral Materials SciencePositron emissionAtomic physicsBeam (structure)Applied Physics A Solids and Surfaces
researchProduct

New Schemes for the Production and Spectroscopy of Positronium

1989

The rate of positronium formation has been increased by 2–3 orders of magnitude using recently developed accelerator based slow positron sources. This opens the possibility of improvements of precision experiments on the Ps atom as well as new experiments on excited states. First evidence for enhanced metastable Ps formation is presented and future possibilities are discussed.

Materials sciencePositronlawOrders of magnitude (temperature)MetastabilityExcited stateAtomParticle acceleratorPhysics::Atomic PhysicsAtomic physicsSpectroscopylaw.inventionPositronium
researchProduct