Search results for "Particle accelerator"
showing 10 items of 180 documents
Collimation for CLIC
2003
The collimation system of the Compact Linear Collider (CLIC) must fulfil a number of conflicting requirements, namely it should (1) remove beam halo to reduce the detector background, (2) provide a minimum distance between collimators and collision point for muon suppression, (3) ensure collimator survival and machine protection against errand beam pulses, (4) not be excessively long, and (5) not amplify incoming trajectory fluctuations via the collimator wake fields. Two optical systems have been designed — the first linear, the second non‐linear —, which promise to meet all these requirements for the design beam energy of 1.5 TeV. We decribe the various design criteria, a preliminary perf…
Coupling MCNP-DSP and LAHET Monte Carlo Codes for Designing Subcriticality Monitors for Accelerator-Driven Systems
2001
The design of reactivity monitoring systems for accelerator-driven systems must be investigated to ensure that such systems remain subcritical during operation. The Monte Carlo codes LAHET and MCNP-DSP were combined together to facilitate the design of reactivity monitoring systems. The coupling of LAHET and MCNP-DSP provides a tool that can be used to simulate a variety of subcritical measurements such as the pulsed neutron, Rossi-α, or noise analysis measurements.
A three domain controller for a high frequency high power four quadrant power converter for superconducting magnets
2002
The paper describes the implementation of a controller that orchestrates the functioning of three subsystems that implement a high energy converter (/spl plusmn/1500 A, /spl plusmn/15 V) that supplies a superconducting magnet to be used in particle accelerators. The performance of the whole system, in accordance to specifications, is documented with experimental results.
Extension of Electron Monte Carlo Dose Calculation in Eclipse to Siemens Linear Accelerators
2009
Initially, the implementation of the macro Monte Carlo (MC) method into Eclipse (Varian Medical Systems), named eMC, was carried out for Varian accelerators only. In this work eMC algorithm has been modified to allow also accurate dose calculations for electron beams for Siemens accelerators.
A status report of the multipurpose superconducting electron cyclotron resonance ion source
2007
Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up to now since the time of pioneering experiment of R. Geller at CEA, Grenoble, and this trend is not deemed to get the saturation at least in the next decade, according to the increased availability of powerful magnets and microwave generators. Electron density above 1013 cm(-3) and very high current of multiply charged ions are expected with the use of 28 GHz microwave heating and of an adequate …
Influence of gravity vector on eye movement elicited by linear acceleration.
1991
When the body/head motion is sensed by otolith organs, they respond not only to the resultant acceleration of the motion but also to the gravitational force. We investigated the influence of the gravity vector on the otolithic-ocular reflex caused by motion in normal subjects. The sled type linear accelerator, moving back and forth with a frequency of 0.25 Hz and an amplitude of 2 m, generated right-left linear acceleration with a maximum magnitude of 0.5 g. We tested every subject under seven different postures: 1) 135 degrees forward tilted (F.T.), 2) 90 degrees F.T., 3) 45 degrees F.T., 4) upright sitting, 5) 45 degrees backward tilted (B.T.), 6) 90 degrees B.T., and 7) 135 degrees B.T. …
Beam-based alignment of SRF cavities in an electron injector linac
2018
Proper alignment of accelerating cavities is an important issue concerning beam quality of linear rf-accelerators. In particular, SRF cavities of injector linacs using high accelerating gradients on low-velocity electron beams can deteriorate the beam quality significantly when not aligned sufficiently. On the other hand, knowing the exact position of every cavity after several cool-down cycles of a cryomodule can be difficult depending on the particular module design. We will report on operational experience on the SC injector of the Darmstadt superconducting recirculating linac and ERL (S-DALINAC) showing unwanted effects on beam dynamics and beam quality due to cavity misalignment, such…
Reconstruction of the Longitudinal Phase Portrait for the SC CW Heavy Ion HELIAC at GSI
2019
Proceedings of the 10th International Particle Accelerator Conference The 10th International Particle Accelerator Conference, Melbourne, Australia, 19 May 2019 - 24 May 2019; JACoW Publishing, Geneva, Switzerland 898-901 (2019). doi:10.18429/JACOW-IPAC2019-MOPTS024
Channeling and Radiation of Electrons in Silicon Single Crystals and Si1−xGexCrystalline Undulators
2013
The phenomenon of channeling and the basic features of channeling radiation emission are introduced in a pedestrian way. Both, radiation spectra as well as dechanneling length measurements at electron beam energies between 195 and 855 MeV feature quantum state phenomena for the (110) planar potential of the silicon single crystals. Radiation from a crystalline undulator, produced at the Aarhus University (UAAR), has been investigated at the Mainz Microtron electron accelerator facility MAMI. The 4-period epitaxially grown strained layer Si1−xGex undulator had a period length λu = 9.9 μm. At a beam energy of 375 MeV a broad excess yield around the theoretically expected photon energy of 0.13…
Collimation of Target Induced Halo Following MAGIX at MESA
2019
The Mainz Energy-recovering Superconducting Accelerator (MESA) will be an electron accelerator allowing operation in energy-recovery linac (ERL) mode. It provides the opportunity to operate scattering experiments at energies of ~100 MeV with thin gas-targets. The MESA Internal Gas Target Experiment (MAGIX) aims to operate windowless jet targets and different gases up to Xenon to search for possible dark photon interactions, to precisely measure the magnetic proton radius and astrophysical S-factors. Investigations on the impact of the target on beam dynamics and beam losses are required for machine safety and to examine limits to ERL operation. The goal of this work is to understand target …