Search results for "Particle detector"

showing 10 items of 200 documents

A calorimeter for the precise determination of the activity of the 144Ce-144Pr anti-neutrino source in the SOX experiment

2018

We describe the design and the performance of a high precision thermal calorimeter, whose purpose was the measurement of the total activity of the 144Ce-144Pr anti-neutrino source of the SOX (Short distance neutrino Oscillation with BoreXino) experiment. SOX aimed at the search for eV-scale sterile neutrinos by means of the Borexino detector at the Laboratori Nazionali del Gran Sasso in Italy and of a very powerful artificial anti-neutrino source located at 8.51 m from the detector center. In order to obtain the required sensitivity, the activity of the source (approximately 150 kCi) had to be known at 1% precision. In this work we report the design of the experimental apparatus and the res…

PhysicsRadiation monitoringPhysics::Instrumentation and Detectors010308 nuclear & particles physicsDetector01 natural sciencesParticle detectorCalorimeterNuclear physicsCalorimetersNeutrino detectorMockup0103 physical sciencesHigh Energy Physics::ExperimentNeutrinoCalorimeters; Radiation monitoring; Instrumentation; Mathematical Physics010306 general physicsNeutrino oscillationInstrumentationMathematical PhysicsBorexinoJournal of Instrumentation
researchProduct

Search for the radioactivity of 180mTa using an underground HPGe sandwich spectrometer

2009

Abstract The radioactivity of 180m Ta has never been detected. The present attempt to detect it was carried out using a newly developed HPGe sandwich spectrometer installed 500 m water equivalent underground in the HADES laboratory. The sample consisted of 6 discs of tantalum of natural isotopic composition with a total mass of 1500 g and a total mass for 180 Ta of 180 mg. The sample was measured for 68 days and the resulting lower bound for the half-life of 180m Ta was 2.0×10 16  y, which is a factor of 2.8 higher than the previous highest value.

PhysicsRadiationIsotopeSpectrometerRadiochemistryTantalumchemistry.chemical_elementTantalumMass spectrometryParticle detectorSemiconductor detectorSpectrometry GammaRadioactivitychemistryMeasuring instrumentGamma spectroscopyHalf-LifeApplied Radiation and Isotopes
researchProduct

Study of the γ decay of high-lying states in 208Pb via inelastic scattering of 17O ions

2014

A measurement of the high-lying states in 208Pb has been made using 17O beams at 20 MeV/u. The gamma decay following inelastic excitation was measured with the detector system AGATA Demonstrator based on segmented HPGe detectors, coupled to an array of large volume LaBr3:Ce scintillators and to an array of Si detectors. Preliminary results in comparison with (γ,γ’) data, for states in the 5-8 MeV energy interval, are presented.

PhysicsScatteringPhysics::Instrumentation and DetectorsPhysicsQC1-999Gamma rayInelastic scatteringParticle detectorSemiconductor detectorIonNuclear physicsPhysics and Astronomy (all)AGATAHigh Energy Physics::ExperimentNuclear ExperimentRadioactive decayEPJ Web of Conferences
researchProduct

Precision Lifetime Measurements Using LaBr3 Detectors With Stable and Radioactive Beams

2013

A range of high resolution gamma-ray spectroscopy measurements have been carried out using arrays which include a number of Cerium-doped Lanthanum-Tribromide (LrBr3 (Ce)) scintillation detectors used in conjunction with high-resolution hyper-pure germanium detectors. Examples of the spectral and temporal responses of such set-ups, using both standard point radioactive sources 152 Eu and 56 Co, and in-beam fusionevaporation reaction experiments for precision measurements of nuclear excited states in 34 P and 138 Ce are presented. The current and future use of such arrays at existing (EURICA at RIKEN) and future (NUSTAR at FAIR) secondary radioactive beam facilities for precision measurements…

PhysicsScintillation010308 nuclear & particles physicsPhysicsQC1-999DetectorAstrophysics01 natural sciences7. Clean energyParticle detectorSemiconductor detectorNuclear physicsExcited state0103 physical sciencesScintillation counterMeasuring instrumentPhysics::Accelerator PhysicsGamma spectroscopy010306 general physicsNuclear ExperimentEPJ Web of Conferences
researchProduct

Recoil-isomer tagging techniques at RITU

2003

Techniques have been developed to study isomeric states in nuclei with the use of RITU (gas filled separator) at the University of Jyvaskyla. The first was the recoil-isomer tagging technique initially, utilised by D.M. Cullen to study the K π = 8− isomeric state in 138Gd [1]. The juro-sphere array was employed in conjunction with ritu and a focal plane array which consisted of several Compton-suppressed Germanium detectors, placed in close geometry around a multi wire proportional counter (mwpc) and a silicon strip detector used for the implantation of recoiling nuclei. This technique correlates prompt and delayed γ-ray transitions across isomeric states and identifies the lifetime of the …

PhysicsSpectrometer010308 nuclear & particles physicsProportional counter7. Clean energy01 natural sciencesParticle detectorParticle identificationCharged particleSemiconductor detectorNuclear physicsRecoil0103 physical sciencesNeutron010306 general physics
researchProduct

Spectral broadening by incomplete thermalization of the energy in X-ray microcalorimeters with superconducting absorber and NTD-Ge thermal sensor

2004

Abstract We present a model of the response of a cryogenic microcalorimeter with superconducting absorber and phonon sensitive thermal sensor to the absorption of X-ray photons. The model is based on the main microscopic processes responsible for the thermalization of the deposited energy. We use a system of rate equations to describe the energy downconversion in the superconductor and transport to the thermal sensor. The model is a tool to investigate the thermalization efficiency with respect to the device characteristics (i.e. absorber material, geometry), in order to optimize the performances of these detectors. As a first case study, we report results of simulations for a microcalorime…

PhysicsSuperconductivityquasi-particleNuclear and High Energy PhysicsPhotonbusiness.industryPhononx-ray spectroscopymicrocalorimeterParticle detectorgermaniumThermalisationOpticsCondensed Matter::Superconductivitynumerical simulationNeutronAtomic physicsAbsorption (electromagnetic radiation)businessInstrumentationDoppler broadening
researchProduct

Neutrinoless double beta decay with 82 SeF 6 and direct ion imaging

2018

We present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. Combining techniques pioneered in high pressure xenon gas such as topological discrimination, with the high Q-value afforded by double beta decay isotope $^{82}$Se, a promising new detection technique is outlined. Lack of free electrons in SeF$_6$ mandates the use of an ion TPC. The microphysics of ion production and drift, which have many nuances, are explored. Background estimates are produced suggesting such a detector may achieve background indices of better than 1 count per ton per year in the region of interest at the 100~kg scale, and still better at the ton-s…

PhysicsTime projection chamberPhysics - Instrumentation and Detectors010308 nuclear & particles physicschemistry.chemical_elementFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)01 natural sciences7. Clean energyBeta decayParticle detectorIonHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)XenonchemistryDouble beta decay0103 physical sciences010306 general physicsInstrumentationMathematical PhysicsRadioactive decayLeptonJournal of Instrumentation
researchProduct

The RICH counter in the CERN hyperon beam experiment

1992

Abstract The hyperon beam experiment WA89 at the CERN-SPS uses a ring imaging Cherenkov counter (RICH) for identification of secondaries from ∑ − N reactions. Cherenkov photons are generated in a 5 m long radiator volume filled with nitrogen at atmospheric pressure and detected in drift chambers. The drift chambers cover an active surface of 1.6 × 0.75 m 2 , with a maximum drift path of 41 cm. Photoelectrons are counted on 1280 wires with a pitch of 2.54 mm, equipped with multihit TDCs. The counting gas is ethane saturated with TMAE at 30°C. The counter was operated in two beam periods in 1990 and 1991. The spatial resolution of the chambers is better than 2 mm and under normal running cond…

PhysicsWire chamberNuclear and High Energy PhysicsPhotonLarge Hadron ColliderAtmospheric pressurePhysics::Instrumentation and DetectorsHyperonPhotoelectric effectCharged particleParticle detectorNuclear physicsVolume (thermodynamics)Measuring instrumentHigh Energy Physics::ExperimentDetectors and Experimental TechniquesAtomic physicsInstrumentationCherenkov radiationBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Possible detection of a radio event correlated with a γ-ray burst

1977

COSMIC bursts of electromagnetic radiation, both isolated and in connection with other impulsive astrophysical phenomena, have been sought for many years1, with only one suggestive positive result2, until, in 1973, the discovery of γ-ray bursts3 of cosmic origin prompted a new series of observations4. In 1975 we started a systematic search for electromagnetic bursts at v.h.f. and u.h.f. The system, based at Medicina (Bologna, Italy), is semi-automatic and assures highly efficient data collection. Simultaneous observations at different frequencies facilitate the evaluation of disturbances of local origin and, hopefully, their isolation. Regular observations started in July 1976, and we repor…

PhysicsX-ray astronomyMultidisciplinaryCOSMIC cancer databaseGamma rayAstrophysical PhenomenaAstrophysicsGamma-ray burstElectromagnetic radiationEvent (particle physics)Particle detectorNature
researchProduct

Simbol-X Mirror Module Thermal Shields: I-Design and X-Ray Transmission

2009

The Simbol‐X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X‐ray transmission.

Physicsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsShieldsX- and gamma-ray telescopes and instrumentation Astronomical and space-research instrumentation Optical coatingsParticle detectorlaw.inventionTelescopeOpticsOptical coatingSettore FIS/05 - Astronomia E AstrofisicaTransmission (telecommunications)lawElectromagnetic shieldingThermalMeasuring instrumentbusiness
researchProduct