Search results for "Pattern"
showing 10 items of 4203 documents
Variable fractional Fourier processor: a simple implementation
1997
A new set of optical implementations of the fractional Fourier transform (FRT) is developed by use of Wigner matrix algebra. The reinterpretation of some elementary operations that synthesize a rotation in the phase-space domain allows us to propose a lensless setup for obtaining the FRT. This compact configuration is also very flexible, because the fractional degree of the transformation can be varied continuously by shifting the input and the output planes along the optical axis by proper amounts. The above results permit one to build an optical FRT processor formed by two FRT systems in cascade, with a spatial filter between them. We present the design of such a variable FRT processor, w…
Single-channel polychromatic pattern recognition by the use of a joint-transform correlator.
2010
We present a single-channel system for color image recognition that is based on a joint-transform correlator setup. The color images are encoded as phase and amplitude functions, inspired from the Munsell color representation. A real-time implementation of the new codification method can be achieved by the use of a spatial light modulator operating in phase-only modulation mode. We determine the optimal codification for a linear color-phase code. Its performance is compared with a conventional multichannel correlator by means of computer simulations. Experimental results are also presented.
ICA of full complex-valued fMRI data using phase information of spatial maps.
2015
Background ICA of complex-valued fMRI data is challenging because of the ambiguous and noisy nature of the phase. A typical solution is to remove noisy regions from fMRI data prior to ICA. However, it may be more optimal to carry out ICA of full complex-valued fMRI data, since any filtering or voxel-based processing may disrupt information that can be useful to ICA. New method We enable ICA of the full complex-valued fMRI data by utilizing phase information of estimated spatial maps (SMs). The SM phases are first adjusted to properly represent spatial phase changes of all voxels based on estimated time courses (TCs), and then these are used to segment the voxels into BOLD-related and unwant…
Speckle based sensing device for fast detection of malaria
2012
We propose a new technique for malaria detection. It is based upon extraction of correlation based statistics of speckle patterns generated while illuminating red blood cells with a laser and inspecting them under a microscope.
Optoelectronic Information Encryption with Incoherent Light
2005
Echocardiographic Image Analysis Based on the Evaluation of first Order Speckle Statistics
1992
Basic theoretical considerations on the statistical properties of the speckle phenomenon indicate that a conventional quantization (intervals of uniform width) of the received and envelope detected RF — signal is not adequate. We therefore propose a quantization scheme which is based on the application of quantization intervals producing always the same confidence level (adaptive quantization). The advantages are: homogenous distribution of speckle noise reduction to about 10 – 20 significant quantization levels (with neglectable loss of morphological information) quantitative measure (confidence level) of the separability of regions represented with different quantization levels. We furthe…
P1450Effect of overweight and obesity on left ventricular longitudinal multi-layer strain: a speckle tracking two-dimensional echocardiographic study
2017
Assessment of image quality of intracoronary ultrasound systems with tissue-equivalent vessel phantoms
2002
Imaging of vascular structures by intracoronary ultrasound (ICUS) is finding more and more applications in coronary diagnosis and in the assessment of interventional access. The authors describe a method for easy and quick production of tissue-equivalent vessel phantoms from a special hydrocolloid. The mechanical tolerance is less than 3/100 mm. With these phantoms the authors tested the calibration and measured the resolution properties of the SONOS intravascular ultrasonic system (Hewlett Packard). The measurements revealed a slight space related underestimation of diameters up to 280 /spl mu/m. Using cross correlation and auto correlation functions the authors analyzed digitized ultrason…
IS A 3D SPECKLE TRACKING ALGORITHM SYNONYMOUS WITH BETTER ESTIMATION OF LEFT VENTRICULAR FUNCTION?
2012
Multi-speckle autocorrelation spectroscopy — a new strategy to monitor ultraslow dynamics in dense and nonergodic media
2007
We present a modification of the conventional dynamic light scattering set-up which allows to monitor the intensity fluctuations of many independent spatial Fourier components of the density fluctuations, i.e. “speckles”, simultaneously by using a charge-coupled device (CCD) camera as area detector. By averaging over the intensity autocorrelation function the final 10–20% decay of the intermediate scattering function in very dense colloidal dispersions is obtained with much higher accuracy. At the same time this multi-speckle autocorrelation spectroscopy provides an alternative route for constructing ensemble-averaged intermediate scattering functions in nonergodic media by replacing the av…