Performance of amines as silanol suppressors in reversed-phase liquid chromatography
2016
In reversed-phase liquid chromatography, cationic basic compounds yield broad and asymmetrical peaks, as a result of their ionic interaction with the anionic free silanol groups present in the silica-based stationary phases (commonly derivatised with C18 groups). A simple way to improve the peak shape is the addition to the hydro-organic mobile phase of a reagent (usually called additive) with cationic character. This associates with the stationary phase to prevent the access of analytes to the free silanol groups. Cationic additives may interact electrostatically with the anionic silanols. The hydrophobic region of the additive may also associate with the alkyl chains bound to the stationa…
Detector supports: application to aliphatic amines in wastewater
2005
Abstract Solid support assisted derivatization coupled to diffuse reflectance spectroscopy (DRS) was proposed and proved useful for the detection and quantification of aliphatic amines in water as an example. Dabsyl chloride (DBS), ninhydrin and sodium 1,2-naphtoquinone 4-sulphonate (NQS) were assayed as derivatization reagents. C 18 and SDB-XC disks and C 18 cartridges were tested for amine retention and after that derivatization. The decrease of the orange colour of dabsyl chloride on SBD-XC disks produced by the formation of its derivative with methylamine in the support (10 min at 100 °C) allowed the selective determination of the amine at concentration level equal or higher than 0.5 mg…
Evaluation of C18 adsorbent cartridges for sampling and derivatization of primary amines in air
2004
Abstract The sampling efficiency of C18 solid-phase extraction cartridges was investigated for methylamine, ethylamine, propylamine, butylamine and pentylamine, in air. Determination of these analytes was based on derivatization with o-phthaldialdehyde–N-acetylcysteine (OPA–NAC) on the solid support and fluorescence detection at λexcitation=330 nm and λemission=440 nm of the eluted derivatives. The calibration model derived from aqueous standards was statistically comparable with the calibration model for air standards. Aqueous amines can be used as standards. The method was useful for calculating short-term exposure limits (STEL). A sampling time of 15 min at 30 ml min−1 was employed. Good…
A microanalytical method for ammonium and short-chain primary aliphatic amines using precolumn derivatization and capillary liquid chromatography.
2007
Abstract A new microscale method is presented for the determination of ammonium and primary short-chain aliphatic amines (methylamine, ethylamine, propylamine, n -butylamine and n -pentylamine) in water. The assay uses precolumn derivatization with the reagent o -phthaldialdehyde (OPA) in combination with the thiol N -acetyl- l -cysteine (NAC), and capillary liquid chromatography with UV detection at 330 nm. The described method is very simple and rapid as no preconcentration of the analytes is necessary, and the volume of sample required is only 0.1 mL. Under the proposed conditions good linearity has been obtained up to a concentration of the analytes of 10.0 mg L −1 , the limits of detec…
Sensitive determination of aliphatic amines in water by high-performance liquid chromatography with chemiluminescence detection.
2004
A sensitive method has been developed for liquid chromatographic determination of short aliphatic amines in water samples. Analytes are preconcentrated and dansylated on solid sorbents (C18 solid-phase extraction cartridges). The dansyl derivatives are chromatographed and post-column mixed with peroxyoxalate (TCPO) and H2O2 in order to perform chemiluminescence detection. Optimal results have been obtained using a sample volume of 5 ml. The method has been applied to the quantification or screening of several aliphatic amines: methylamine, ethylamine, butylamine, diethylamine, pentylamine and hexylamine. The screening procedure has been developed including also polyamines (putrescine, cadav…
Rapid fluorimetric assay for primary amine groups in water samples
2003
Bond Elut C(18) solid-phase extraction cartridges were used for pre-concentration followed by derivatization with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) of primary amines in water. Optimal conditions were: conditioning the cartridges with borate buffer pH 10.4, retention of the primary amines, addition of the OPA-NAC(3.7 mmol L(-1)) 1:1 molar ratio and borate buffer pH 8, elution of the isoindol with MeOH-borate buffer (9:1) pH 10.2 and fluorescence measurement. The equations of the calibration graphs for methylamine, ethylamine, propylamine, butylamine, pentylamine, and beta-phenylethylamine at lambda(excitation)=330 nm and lambda(emission)=440 nm, in the optimal conditions are pres…