Search results for "Percutaneous"
showing 10 items of 471 documents
Dual lumen microcatheters for recanalisation of chronic total occlusions: A EuroCTO Club expert panel report
2021
Dual lumen microcatheters (DLMC) have become indispensable tools in the setting of percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Other than allowing preservation and treatment of bifurcated coronary branches within or in the proximity of the CTO-body, they enable the use of modified parallel wiring, antegrade dissection and re-entry, collateral selection and retrograde negotiation of the distal CTO-cap. This Euro-CTO consensus document describes current DLMCs and suggests a practical guide to anatomies and techniques in which these devices are applicable.
Computed Tomography of HCC
2016
Contrast-enhanced CT allows an accurate noninvasive diagnosis of Hepatocellular Carcinoma (HCC) nodules, and assessment of hepatic vascular anatomy and patency. The use of state-of-the-art equipment and of a tailored protocol is crucial. CT results help to detect and stage HCC, select the best treatment option, and evaluate response to therapy. In this chapter, the CT protocol for the cirrhotic liver, the CT features of HCC before and after treatment and of portal vein thrombosis will be described.
Management of Coronary Artery Perforation
2020
Coronary artery perforation (CAP) is a rare but potentially life-threatening complication of percutaneous coronary intervention (PCI), however if recognized and managed promptly, its adverse consequences can be minimized. Risk factors for CAP include the use of advanced PCI technique (such as atherectomy and chronic total occlusion interventions) and treatment of severely calcified lesions. There are 3 major types of CAP depending on location: (a) large vessel perforation, (b) distal vessel perforation, and (c) collateral perforation. Large vessel perforation is usually treated with implantation of a covered stent, whereas distal and collateral vessel perforations are usually treated with c…
EpCAM and microvascular obstruction in patients with STEMI: a cardiac magnetic resonance study
2021
Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – EU funding. Main funding source(s): This study was funded by “Instituto de Salud Carlos III” and “Fondos Europeos de Desarrollo Regional FEDER” Bachground. Microvascular obstruction (MVO) is negatively associated with cardiac structure and worse prognosis after ST-segment elevation myocardial infarction (STEMI). Epithelial cell adhesion molecule (EpCAM), involved in endothelium adhesion, is an understudied area in the MVO setting. Purpose. We aimed to evaluate whether EpCAM is associated with the appearance of cardiac magnetic resonance (CMR)-derived MVO and long-term systolic function in reperfused STEMI. Methods.…
Biliary complications after liver transplantation: current perspectives and future strategies
2021
Importance: Liver transplantation (LT) is a life-saving therapy for patients with end-stage liver disease and with acute liver failure, and it is associated with excellent outcomes and survival rates at 1 and 5 years. The incidence of biliary complications (BCs) after LT is reported to range from 5% to 20%, most of them occurring in the first three months, although they can occur also several years after transplantation.Objective: The aim of this review is to summarize the available evidences on pathophysiology, risk factors, diagnosis and therapeutic management of BCs after LT.Evidence Review: a literature review was performed of papers on this topic focusing on risk factors, classificatio…
Traffic-associated air pollution as a risk factor for cancer in individuals with coronary artery disease.
2018
Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patient…
2018
Introduction The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity sco…
1-Year Outcomes of Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Stents
2016
Abstract Objectives The purpose of this study was to compare the 1-year outcomes of the ABSORB everolimus-eluting bioresorbable scaffold (BRS) (Abbott Vascular, Santa Clara, California) and the XIENCE everolimus-eluting stent (EES) (Abbott Vascular) in patients undergoing percutaneous coronary intervention. Background Randomized studies of the ABSORB BRS have been performed in selected patient and lesion scenarios. The available registries of the ABSORB BRS reflect real-world practice more closely compared with randomized studies, but most of them are limited by the small sample size and the lack of comparative outcomes versus second-generation drug-eluting stents. Methods A total of 1,189 …
P798Outcome of percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in patients with STEMI as compared to stab…
2018
TCT-441 Optical Coherence Tomography assessment of the implantation of Everolimus-Eluting Bioresorbable Scaffolds against angiographic assessment: th…
2016
Bioresorbable Vascular Scaffolds (BVS) are the newest generation of stents for use during Percutaneous Coronary Intervention. However, as history has demonstrated, each development in stent technology has been associated with its own specific complications. With BVS, there are reports that recoil is